Development of screen-printed electrode based immunosensor for the detection of HER2 antigen in human serum samples

被引:53
作者
Tallapragada, Sagarika Deepthy [1 ]
Layek, Keya [2 ]
Mukherjee, Runu [3 ]
Mistry, Kalyan Kumar [2 ]
Ghosh, Monidipa [1 ]
机构
[1] Natl Inst Technol, MG Ave, Durgapur 713209, India
[2] CSIR, Cent Mech Engn Res Inst, MG Ave, Durgapur 713209, India
[3] Durgapur Steel Plant Hosp, JM Sengupta Rd,B Zone, Durgapur 713205, India
关键词
Screen printed electrode; Immunosensor; Cyclic voltammetry; Human Epidermal Growth Factor Receptor-2; (HER2) antigen; Enzyme linked immunosorbent assay (ELISA); NANOPARTICLE-BASED BIOSENSORS; METASTATIC BREAST-CANCER; ELECTROCHEMICAL IMMUNOSENSOR; EXTRACELLULAR DOMAIN; TRASTUZUMAB; UTILITY;
D O I
10.1016/j.bioelechem.2017.06.009
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, an immunosensor based on screen-printed electrode (SPE) has been developed for the detection of Human Epidermal Growth Factor Receptor-2 (HER2) antigen. The SPEs were fabricated and a sandwich enzyme linked immunosorbent assay (ELISA) format was followed for the construction of the immunosensor. The capture antibody (mouse anti-human ErbB2) was coated onto the electrode surface without any prior surface modification, followed by the addition of recombinant human HER2 antigen. Biotinylated goat anti-human ErbB2 was used as the detection antibody which was linked to streptavidin conjugated horseradish peroxidase (HRP). 3,3',5,5'-tetramethylbenzidine (TMB) was used as the substrate. The redox reaction was measured using cyclic voltammetry at scan rate of 50 mV/s for the quantification of the antigen in solution. The biotin-avidin chemistry enabled the accurate detection of the antigen in nanogram levels. The amperometric signal obtained increased linearly with increase in the HER2 concentration and two-fold linear range was obtained between 5 ng/ml-20 ng/ml and 20-200 ng/ml respectively. The limit of detection (LOD) and the limit of quantification (LOQ) of this immunosensor were found to be 4 ng/ml and 5 ng/ml respectively. The detection of HER2 in the serum samples of invasive and non-invasive breast cancer patients has been realized. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 20 条
[1]   An Electrochemical Immunoassay for HER2 Detection [J].
Al-Khafaji, Q. A. M. ;
Harris, M. ;
Tombelli, S. ;
Laschi, S. ;
Turner, A. P. F. ;
Mascini, M. ;
Marrazza, G. .
ELECTROANALYSIS, 2012, 24 (04) :735-742
[2]   An electrochemical immunosensor for detection of a breast cancer biomarker based on antiHER2-iron oxide nanoparticle bioconjugates [J].
Emami, Mahdi ;
Shamsipur, Mojtaba ;
Saber, Reza ;
Irajirad, Rasoul .
ANALYST, 2014, 139 (11) :2858-2866
[3]   Clinical utility of serum HER2/neu in monitoring and prediction of progression-free survival in metastatic breast cancer patients treated with trastuzumab-based therapies [J].
Esteva, FJ ;
Cheli, CD ;
Fritsche, H ;
Fornier, M ;
Slamon, D ;
Thiel, RP ;
Luftner, D ;
Ghani, F .
BREAST CANCER RESEARCH, 2005, 7 (04) :R436-R443
[4]   Advantages and Disadvantages of Technologies for HER2 Testing in Breast Cancer Specimens [J].
Furrer, Daniela ;
Sanschagrin, Francois ;
Jacob, Simon ;
Diorio, Caroline .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2015, 144 (05) :686-703
[5]   Detection of HER2 breast cancer biomarker using the opto-fluidic ring resonator biosensor [J].
Gohring, John T. ;
Dale, Paul S. ;
Fan, Xudong .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :226-230
[6]   Gold-nanoparticle-based biosensors for detection of enzyme activity [J].
Hutter, Eliza ;
Maysinger, Dusica .
TRENDS IN PHARMACOLOGICAL SCIENCES, 2013, 34 (09) :497-507
[7]   Clinicopathologic significance of the basal-like subtype of breast cancer: a comparison with hormone receptor and Her2/neu-overexpressing phenotypes [J].
Kim, Mi-Jung ;
Ro, Jae Y. ;
Ahn, Sei-Hyun ;
Kim, Hak Hee ;
Kim, Sung-Bae ;
Gong, Gyungyub .
HUMAN PATHOLOGY, 2006, 37 (09) :1217-1226
[8]   Chromogenic in situ hybridization (CISH) to detect HER2 gene amplification in breast and gastric cancer: Comparison with immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) [J].
Kiyose, Shinichiro ;
Igarashi, Hisaki ;
Nagura, Kiyoko ;
Kamo, Takaharu ;
Kawane, Kazunori ;
Mori, Hiroki ;
Ozawa, Takachika ;
Maeda, Matsuyoshi ;
Konno, Keisuke ;
Hoshino, Hideaki ;
Konno, Hiroyuki ;
Ogura, Hiroyuki ;
Shinmura, Kazuya ;
Hattori, Naohiko ;
Sugimura, Haruhiko .
PATHOLOGY INTERNATIONAL, 2012, 62 (11) :728-734
[9]   Utility of Serum HER2 Extracellular Domain Assessment in Clinical Decision Making: Pooled Analysis of Four Trials of Trastuzumab in Metastatic Breast Cancer [J].
Lennon, Sian ;
Barton, Claire ;
Banken, Ludger ;
Gianni, Luca ;
Marty, Michel ;
Baselga, Jose ;
Leyland-Jones, Brian .
JOURNAL OF CLINICAL ONCOLOGY, 2009, 27 (10) :1685-1693
[10]   Gold nanoparticle-based biosensors [J].
Li, Yuanyuang ;
Schluesener, Hermann J. ;
Xu, Shunqing .
GOLD BULLETIN, 2010, 43 (01) :29-41