Analysis of carboxylic acid metabolites from the tricarboxylic acid cycle in Bacillus subtilis cell extract by capillary electrophoresis using an indirect photometric detection method

被引:32
作者
Markuszewski, MJ [1 ]
Otsuka, K
Terabe, S
Matsuda, K
Nishioka, T
机构
[1] Himeji Inst Technol, Grad Sch Sci, Kamigori, Hyogo 6781297, Japan
[2] Kyoto Univ, Grad Sch Agr, Sakyo Ku, Kyoto 6068502, Japan
基金
日本学术振兴会;
关键词
Bacillus subtilis; indirect detection; detection; electrophoresis; bacteria; tricarboxylic acid cycle; carboxylic acids;
D O I
10.1016/S0021-9673(03)01063-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With a growing interest in metabolome analysis, there is a need for developing robust methods for analysis of intracellular metabolites profiles in real samples like e.g., bacteria cell. Due to their weak absorbance properties, tri- and dicarboxylic acids from TCA cycle (citric, isocitfic, 2-oxoglutaric, succinic, fumaric, malic) as well as carboxylic acid metabolites from glycolysis pathway, urea cycle and metabolism of amino compounds (formic, pyruvic, lactic, acetic, glutamic) were analyzed by capillary electrophoresis (CE) with indirect UV detection. Using 4 mM 2,6-pyridinedicarboxylic acid as a highly UV absorbing carrier electrolyte, 0.2 mM cetyltrimethylammonium bromide, 10% ethylene glycol and 10% acetonitrile, pH 3.5, carboxylic acids metabolites were analyzed in Bacillus subtilis cell extract from two different cultures: glucose and malate. CE with an electrokinetic injection mode achieved limits of detection in the range of 13-54 ppb (1.12-10(-7) -5.96.10(-7) M). The reproducibility and linearity of method was investigated with RSD for migration time less than 1.3% and acceptable correlation coefficients. The optimized CE method was used to compare metabolome content of cell extract derived from two different culture media containing either glucose or malate as a carbon source. The changes in carboxylic acid metabolites profile were observed depending from used culture medium. Carboxylic acid concentrations ranged: in cell extract from malate culture from 59 to 0.5 muM for lactate and citrate, respectively, and in cell extract from glucose culture from 133 to 0.5 muM for glutamate and citrate, respectively. Appropriate concentrations of carboxylic acid in the single bacterium cell were estimated at mM and sub-mM levels. (C) 2003 Elsevier B.V. All fights reserved.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 21 条
[1]  
[Anonymous], J CHROMATOGR A
[2]   Picomolar analysis of flavins in biological samples by dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection [J].
Britz-McKibbin, P ;
Markuszewski, MJ ;
Iyanagi, T ;
Matsuda, K ;
Nishioka, T ;
Terabe, S .
ANALYTICAL BIOCHEMISTRY, 2003, 313 (01) :89-96
[3]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[4]   MATHEMATICAL-MODELING OF FIELD-AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2866-2869
[5]   Determination of low-molecular-mass carboxylic acids in atmospheric aerosol and vehicle emission samples by capillary electrophoresis [J].
Dabek-Zlotorzynska, E ;
Piechowski, M ;
McGrath, M ;
Lai, EPC .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (02) :331-345
[6]  
Dabek-Zlotorzynska E, 2000, LC GC N AM, V18, P950
[7]  
Dawson RMC, 1991, DATA BIOCH RES, P46
[8]   Design of background electrolytes for indirect detection of anions by capillary electrophoresis [J].
Doble, P ;
Macka, M ;
Haddad, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (01) :10-17
[9]   Factors influencing the choice of buffer in background electrolytes for indirect detection of fast anions by capillary electrophoresis [J].
Doble, P ;
Macka, M ;
Haddad, PR .
ELECTROPHORESIS, 1998, 19 (12) :2257-2261
[10]   Metabolomics - the link between genotypes and phenotypes [J].
Fiehn, O .
PLANT MOLECULAR BIOLOGY, 2002, 48 (1-2) :155-171