Minibeam radiation therapy: A micro- and nano-dosimetry Monte Carlo study

被引:12
|
作者
Dos Santos, M. [1 ]
Delorme, R. [2 ,3 ]
Salmon, R. [2 ,3 ]
Prezado, Y. [2 ,3 ]
机构
[1] IRSN, Lab Radiobiol Accidental Exposures LRAcc, Dept Radiobiol & Regenerat Med SERAMED, F-92260 Fontenay Aux Roses, France
[2] Univ Paris Saclay, Univ Paris Sud, CNRS, IMNC, F-91400 Orsay, France
[3] Univ Paris IMNC, F-91400 Orsay, France
关键词
DNA damage; GEANT4; minibeam radiation therapy; Monte Carlo simulations; GLIOMA-BEARING RATS; DNA-DAMAGE; IONIZING-RADIATION; SIMULATION; BEAMS; RADIOTHERAPY; CELLS; IONS;
D O I
10.1002/mp.14009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Minibeam radiation therapy (MBRT) is an innovative strategy based on a distinct dose delivery method that is administered using a series of narrow (submillimetric) parallel beams. To shed light on the biological effects of MBRT irradiation, we explored the micro- and nanodosimetric characteristics of three promising MBRT modalities (photon, electron, and proton) using Monte Carlo (MC) calculations. Methods Irradiation with proton (100 MeV), electron (300 MeV), and photon (effective energy of 69 keV) minibeams were simulated using Geant4 MC code and the Geant4-DNA extension, which allows the simulation of energy transfer points with nanometric accuracy. As the target of the simulations, cells containing spherical nuclei with or without a detailed description of the DNA (deoxyribonucleic acid) geometry were placed at different depths in peak and valley regions in a water phantom. The energy deposition and number of events in the cell nuclei were recorded in the microdosimetry study, and the number of DNA breaks and their complexity were determined in the nanodosimetric study, where a multi-scale simulation approach was used for the latter. For DNA damage assessment, an adapted DBSCAN clustering algorithm was used. To compare the photon MBRT (xMBRT), electron MBRT (eMBRT), and proton MBRT (pMBRT) approaches, we considered the treatment of a brain tumor located at a depth of 75 mm. Results Both mean energy deposition at micrometric scale and DNA damage in the "valley" cell nuclei were very low as compared with these parameters in the peak region at all depths for xMBRT and at depths of 0 to 30 mm and 0 to 50 mm for eMBRT and pMBRT, respectively. Only the charged minibeams were favorable for tumor control by producing similar effects in peak and valley cells after 70 mm. At the micrometer scale, the energy deposited per event pointed to a potential advantage of proton beams for tumor control, as more aggressive events could be expected at the end of their tracks. At the nanometer scale, all three MBRT modalities produced direct clustered DNA breaks, although the majority of damage (>93%) was composed of isolated single strand breaks. The pMBRT led to a significant increase in the proportion of clustered single strand breaks and double-strand breaks at the end of its range as compared to the entrance (7% at 75 mm vs 3% at 10 mm) in contrast to eMBRT and xMBRT. In the latter cases, the proportions of complex breaks remained constant, irrespective of the depth and region (peak or valley). Conclusions Enhanced normal tissue sparing can be expected with these three MBRT techniques. Among the three modalities, pMBRT offers an additional gain for radioresistant tumors, as it resulted in a higher number of complex DNA damage clusters in the tumor region. These results can aid understanding of the biological mechanisms of MBRT.
引用
收藏
页码:1379 / 1390
页数:12
相关论文
共 50 条
  • [1] Minibeam radiation therapy for the management of osteosarcomas: A Monte Carlo study
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [2] Monte Carlo study of the free radical yields in minibeam radiation therapy
    Masilela, Thongchai A. M.
    Prezado, Yolanda
    MEDICAL PHYSICS, 2023, 50 (08) : 5115 - 5134
  • [3] Impact of cardiosynchronous brain pulsations on Monte Carlo calculated doses for synchrotron micro- and minibeam radiation therapy
    Manchado de Sola, Francisco
    Vilches, Manuel
    Prezado, Yolanda
    Lallena, Antonio M.
    MEDICAL PHYSICS, 2018, 45 (07) : 3379 - 3390
  • [4] β-delayed multiple-particle emitters minibeam radiation therapy: first dosimetric evaluation with Monte Carlo simulations
    Corvino, Angela
    Schneider, Tim
    Prezado, Yolanda
    FRONTIERS IN PHYSICS, 2024, 12
  • [5] Monte Carlo-based dose calculation engine for minibeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Prezado, Y.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 57 - 62
  • [6] Proton minibeam radiation therapy: Experimental dosimetry evaluation
    Peucelle, C.
    Nauraye, C.
    Patriarca, A.
    Hierso, E.
    Fournier-Bidoz, N.
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2015, 42 (12) : 7108 - 7113
  • [7] Monte Carlo study of high-energy light ions for minibeam radiation therapy approach
    Rajabnejad, Mohaddeseh
    Ghasemizad, Abbas
    Zabihi, Azam
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (11):
  • [8] Dosimetry protocol for the preclinical trials in white-beam minibeam radiation therapy
    Prezado, Y.
    Martinez-Rovira, I.
    Thengumpallil, S.
    Deman, P.
    MEDICAL PHYSICS, 2011, 38 (09) : 5012 - 5020
  • [9] Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams
    Chow, James C. L.
    Jiang, Runqing
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12) : 3885 - 3899
  • [10] Challenges for the Implementation of Primary Standard Dosimetry in Proton Minibeam Radiation Therapy
    Cotterill, John
    Flynn, Samuel
    Thomas, Russell
    Subiel, Anna
    Lee, Nigel
    Homer, Michael
    Palmans, Hugo
    De Marzi, Ludovic
    Prezado, Yolanda
    Shipley, David
    Lourenco, Ana
    CANCERS, 2024, 16 (23)