Factors affecting the risk of blood bank specimen hemolysis

被引:26
作者
Tanabe, P
Kyriacou, DN
Garland, F
机构
[1] Northwestern Univ, Feinberg Sch Med, Inst Hlth Serv Res & Policy Studies, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Dept Emergency Med, Chicago, IL 60611 USA
[3] NW Mem Hosp, Blood Bank Lab, Chicago, IL 60611 USA
基金
美国医疗保健研究与质量局;
关键词
hemolysis; blood bank; specimen; intravenous (IV) catheters;
D O I
10.1197/aemj.10.8.897
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To evaluate simultaneously several possible risk factors for blood bank specimen hemolysis. Methods: This was a prospective cohort study of emergency department and labor and delivery patients to estimate the effect of various factors on the risk of blood bank specimen hemolysis. Study variables included patient demographics, type and gauge of needle or catheter, anatomic location of venipuncture, and patient care area. Hemolysis was determined by blood bank laboratory technicians. Cox proportional hazards multivariate regression modeling was performed to estimate the adjusted relative risks for hemolysis. Results: Of the 605 subjects with complete data, 194 (32.1%) subjects had blood specimens drawn directly with a steel needle, and 411 (69.1%) had specimens drawn through a Vialon (BD Medical Systems, Inc., Sandy, UT) intravenous (IV) angiocatheter. The overall risk of hemolysis for all was 7%, 10% for Vialon IV angiocatheters and 1.5% for steel needles. In the multivariate analysis, the factors most closely associated with hemolysis were the use of Vialon IV catheters and sampling from an anatomic site other than the antecubital area. Conclusions: Blood bank specimens drawn from Vialon IV catheters (particularly smaller gauge catheters) and from veins outside the antecubital area are at significantly increased risk to hemolyze.
引用
收藏
页码:897 / 900
页数:4
相关论文
共 9 条
[1]   Hemolysis in serum samples drawn by emergency department personnel versus laboratory phlebotomists [J].
Burns, ER ;
Yoshikawa, N .
LABORATORY MEDICINE, 2002, 33 (05) :378-380
[2]  
Fernandes C M, 1997, J Emerg Med, V15, P735, DOI 10.1016/S0736-4679(97)00158-3
[3]   INTRAVENOUS CATHETER ASPIRATION FOR OBTAINING BASIC ANALYTES DURING INTRAVENOUS-INFUSION [J].
HERR, RD ;
BOSSART, PJ ;
BLAYLOCK, RC ;
KROGER, K ;
ASH, O .
ANNALS OF EMERGENCY MEDICINE, 1990, 19 (07) :789-792
[4]  
Kennedy C, 1996, J Emerg Nurs, V22, P566, DOI 10.1016/S0099-1767(96)80213-3
[5]  
Magill C, 1999, ANN ROY COLL SURG, V81, P270
[6]  
RAISKY F, 1994, ANN BIOL CLIN-PARIS, V52, P523
[7]  
Schwarzer BA, 2001, TRANSFUSION, V41, p138S
[8]  
Seemann S, 2000, J Intraven Nurs, V23, P290
[9]  
STEIGE H, 1971, CLIN CHEM, V17, P1160