Dual-Source Dual-Energy CT Angiography of the Supra-Aortic Arteries with Tin Filter: Impact of Tube Voltage Selection

被引:4
作者
Korn, Andreas [1 ]
Bender, Benjamin [1 ]
Schabel, Christoph [2 ]
Bongers, Malte [2 ]
Ernemann, Ulrike [1 ]
Claussen, Claus [2 ]
Thomas, Christoph [3 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Neuroradiol, Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[3] Univ Dusseldorf, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
关键词
Dual-energy CTA; supra-aortic arteries; tin filter; image quality; spectral CT; SUBTRACTION; STENOSIS; PERFORMANCE;
D O I
10.1016/j.acra.2015.01.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Automatic bone and plaque subtraction (BPS) in computed tomographic angiographic (CTA) examinations using dual-energy CT (DECT) remains challenging because of beam-hardening artifacts in the shoulder region and close proximity of the internal carotid artery to the base of the skull. The selection of the tube voltage combination in dual-source CT influences the spectral separation and the susceptibility for artifacts. The purpose of this study was to assess which tube voltage combination leads to an optimal image quality of head and neck DECT angiograms after bone subtraction. Materials and Methods: Fifty-one patients received tin-filter-enhanced DECT angiograms of the-supra-aortic arteries using two voltage protocols: 24 patients were studied using 80/Sn140 kV and 27 using a 100/Sn140 kV protocol, both protocols with an additional tin filter. A commercially available DE-CTA BPS algorithm was used. Artificial vessel erosions in BPS maximum intensity projections (four-level Likert scale with CTA source data as reference) and vessel signal-to-noise ratio (SNR) were assessed in the level of the shoulders and the base of the skull in each patient and compared. Results: At the level of the shoulder, 100/Sn140 kV achieved higher SNR (23.4 +/- 6.4 at 80/Sn140 kV vs. 35.1 +/- 11.8 at 100/Sn140 kV; P < .0001) with less erosions (erosion score 3.9 +/- 0.4 in 80/Sn140 kV vs. 2.1 +/- 1.3 in 100/Sn140 kV; P < .0001) than 80/Sn140 kV. At the level-of the skull base, erosion scores and objective image quality of arterial segments were comparable with both protocols (P = .14). Conclusions: The 100/Sn140 kV protocol achieved more favorable results for BPS of the supra-aortic arteries than the 80/Sn140 kV protocol.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 23 条
[1]   Carotid Artery Stenosis: Accuracy of Noninvasive Tests-Individual Patient Data Meta-Analysis [J].
Chappell, Francesca M. ;
Wardlaw, Joanna M. ;
Young, Gavin R. ;
Gillard, Jonathan H. ;
Roditi, Giles H. ;
Yip, Brigitte ;
Pell, Jill P. ;
Rothwell, Peter M. ;
Brown, Martin M. ;
Gough, Michael J. ;
Randall, Marc S. .
RADIOLOGY, 2009, 251 (02) :493-502
[2]   Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography [J].
Deng, K. ;
Liu, C. ;
Ma, R. ;
Sun, C. ;
Wang, X. -m. ;
Ma, Z. -t. ;
Sun, X. -l. .
CLINICAL RADIOLOGY, 2009, 64 (05) :534-541
[3]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[4]   Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[5]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1510-1517
[6]   Dual energy CTA of the carotid bifurcation: Advantage of plaque subtraction for assessment of grade of the stenosis and morphology [J].
Korn, A. ;
Bender, B. ;
Thomas, C. ;
Danz, S. ;
Fenchel, M. ;
Naegele, T. ;
Heuschmid, M. ;
Ernemann, U. ;
Hauser, T. K. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) :E120-E125
[7]   Systematic review on the association between calcification in carotid plaques and clinical ischemic symptoms [J].
Kwee, Robert M. .
JOURNAL OF VASCULAR SURGERY, 2010, 51 (04) :1015-1025
[8]   Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging [J].
Lell, M ;
Anders, K ;
Klotz, E ;
Ditt, H ;
Bautz, W ;
Tomandl, BF .
EUROPEAN RADIOLOGY, 2006, 16 (04) :889-897
[9]   New techniques in CT angiography [J].
Lell, Michael M. ;
Anders, Katharina ;
Uder, Michael ;
Klotz, Ernst ;
Ditt, Hendrik ;
Vega-Higuera, Fernando ;
Boskamp, Tobias ;
Bautz, Werner A. ;
Tomandl, Bernd F. .
RADIOGRAPHICS, 2006, 26 :S45-U58
[10]   Dual energy CTA of the supraaortic arteries: Technical improvements with a novel dual source CT system [J].
Lell, Michael M. ;
Hinkmann, Fabian ;
Nkenke, Emeka ;
Schmidt, Bernhard ;
Seidensticker, Peter ;
Kalender, Willi A. ;
Uder, Michael ;
Achenbach, Stephan .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (02) :E6-E12