Improved visualization of hypodense liver lesions in virtual monoenergetic images from spectral detector CT: Proof of concept in a 3D-printed phantom and evaluation in 74 patients

被引:17
作者
Hokamp, N. Grosse [1 ,2 ,3 ]
Obmann, Vc [1 ,2 ]
Kessner, R. [1 ,2 ]
Laukamp, K. R. [1 ,2 ]
Persigehl, T. [3 ]
Haneder, S. [3 ]
Ramaiya, N. [1 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Cologne, Germany
关键词
Dual energy computed tomography; Spectral detector computed tomography; Liver lesions; Virtual monoenergetic images; 3D-printing; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; METAL-ARTIFACT-REDUCTION; IODINE QUANTIFICATION; WINDOW SETTINGS; QUALITY; METASTASES; OPTIMIZATION; ACCURACY; RECONSTRUCTIONS;
D O I
10.1016/j.ejrad.2018.11.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The well-known boost of iodine associated-attenuation in low-keV virtual monoenergetic images (VMI_low) is frequently used to improve visualization of lesions and structures taking up contrast media. This study aimed to evaluate this concept in reverse. Hence to investigate if increased attenuation within the liver allows for improved visualization of little or not-enhancing lesions. Methods: A 3D-printed phantom mimicking the shape of a human liver exhibiting a lesion in its center was designed and printed. Both, parenchyma- and lesion-mimic were filled with different solutions exhibiting 80/ 100/120HU and 0/15/40/60HU, respectively. Further, a total of 74 contrast-enhanced studies performed on a spectral detector CT scanner (SDCT) were included in this retrospective study. Patients had MRI or follow-up proven cysts and/or hypodense metastases. VMI of 40-200 keV as well as conventional images (CI) were reconstructed. ROI were placed in lesion and parenchyma(-mimics) on CI and transferred to VMI. Signal- and contrast-to-noise ratio were calculated (S-/CNR). Further, two radiologists independently evaluated image quality. Data was statistically assessed using ANOVA or Wilcoxon-test. Results: In phantoms, S/CNR was significantly higher in VMI_low. The cyst-mimic in highly attenuating parenchyma-mimic on CI yielded a CNR of 6.4 +/- 0.8; using VMI_40 keV, mildly hypodense lesion-mimic in poorly attenuating parenchyma-mimic exhibited a similar CNR (5.8 +/- 0.9; p <= 0.05). The same tendency was observed in patients (cyst in Cl/metastasis in VMI_40 keV: 4.4 +/- 1.2/3.9 +/- 1.8; p <= 0.05). Qualitative analysis indicated a benefit of VMI_40 keV (p <= 0.05). Conclusions: VMI_low from SDCT allow for an improved visualization of hypodense focal liver lesions exploiting the concept of contrast blooming in reverse.
引用
收藏
页码:114 / 123
页数:10
相关论文
共 43 条
[1]   Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen [J].
Albrecht, Moritz H. ;
Trommer, Jesko ;
Wichmann, Julian L. ;
Scholtz, Jan-Erik ;
Martin, Simon S. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Bodelle, Boris .
INVESTIGATIVE RADIOLOGY, 2016, 51 (09) :582-590
[2]   Improved Image Quality and Detectability of Hypovascular Liver Metastases on DECT with Different Adjusted Window Settings [J].
Altenbernd, Jens ;
Forsting, Michael ;
Lauenstein, Thomas ;
Wetter, Axel .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (03) :228-232
[3]   Dual-energy-CT of hypervascular liver lesions in patients with HCC: investigation of image quality and sensitivity [J].
Altenbernd, Jens ;
Heusner, Till A. ;
Ringelstein, Adrian ;
Ladd, Susanne C. ;
Forsting, Michael ;
Antoch, Gerald .
EUROPEAN RADIOLOGY, 2011, 21 (04) :738-743
[4]  
American Association of Physicists in Medicine (Task Group 204), 2011, SIZE SPEC DOS EST SS
[5]   The AAPM/RSNA physics tutorial for residents - X-ray interactions [J].
Bushberg, JT .
RADIOGRAPHICS, 1998, 18 (02) :457-468
[6]   Liver metastases: Contrast-enhanced ultrasound compared with computed tomography and magnetic resonance [J].
Cantisani, Vito ;
Grazhdani, Hektor ;
Fioravanti, Cristina ;
Rosignuolo, Maria ;
Calliada, Fabrizio ;
Messineo, Daniela ;
Bernieri, Maria Giulia ;
Redler, Adriano ;
Catalano, Carlo ;
D'Ambrosio, Ferdinando .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (29) :9998-10007
[7]   Can dual-energy computed tomography improve visualization of hypoenhancing liver lesions in portal venous phase? Assessment of advanced image-based virtual monoenergetic images [J].
Caruso, Damiano ;
De Cecco, Carlo N. ;
Schoepf, U. Joseph ;
Schaefer, Amanda R. ;
Leland, Parker W. ;
Johnson, Dustin ;
Laghi, Andrea ;
Hardie, Andrew D. .
CLINICAL IMAGING, 2017, 41 :118-124
[8]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[9]   A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions [J].
De Cecco, Carlo N. ;
Caruso, Damiano ;
Schoepf, U. Joseph ;
De Santis, Domenico ;
Muscogiuri, Giuseppe ;
Albrecht, Moritz H. ;
Meinel, Felix G. ;
Wichmann, Julian L. ;
Burchett, Philip F. ;
Varga-Szemes, Akos ;
Sheafor, Douglas H. ;
Hardie, Andrew D. .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3393-3404
[10]   Optimization of window settings for virtual monoenergetic imaging in dual-energy CT of the liver: A multi-reader evaluation of standard monoenergetic and advanced imaged-based monoenergetic datasets [J].
De Cecco, Carlo N. ;
Caruso, Damiano ;
Schoepf, U. Joseph ;
Wichmann, Julian L. ;
Ter Louw, Janet R. ;
Perry, Jonathan D. ;
Picard, Melissa M. ;
Schaefer, Amanda R. ;
Parker, Leland W. ;
Hardie, Andrew D. .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) :695-699