Fluoroscopy, CT, and MR imaging characteristics of a novel primarily bioresorbable flow-diverting stent for aneurysms

被引:2
作者
Morrish, Rosalie [1 ]
Corcoran, Ronan [2 ]
Cooke, Jillian [2 ]
Eesa, Muneer [1 ]
Wong, John H. [1 ]
Mitha, Alim P. [1 ]
机构
[1] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[2] Fluid Biotech Inc, Calgary, AB, Canada
关键词
Fluoroscopy; computed tomography; magnetic resonance; flow diversion; aneurysms;
D O I
10.1177/15910199211060979
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Five to ten percent of the global population have unruptured intracranial aneurysms, and ruptured brain aneurysms cause approximately 500,000 deaths a year. Flow-diverting stent treatment is a less invasive intracranial aneurysm treatment that induces aneurysm thrombosis. The imaging characteristics of a novel primarily bioresorbable flow-diverting stent (BFDS) are assessed in comparison to the leading metal stent using fluoroscopy, CT, and MRI. Methods X-ray/fluoroscopic images of stents were taken using a human cadaveric skull model. CT and MRI were acquired using silicone flow models of residual aneurysms. Images were analyzed with Likert scales in anonymous surveys by neurointerventionalists. Quantitative measurements of radiographic density (CT) and artifact boundary size (CT & MRI) were also obtained. Results Visibility of the BFDS on X-ray was less than the metal stent but deemed adequate for deployment and intraprocedural assessment. The metal stent was more radiopaque than the BFDS on CT, but qualitative assessment was not significantly different for the two stents. MRI imaging was significantly better using the BFDS in terms of overall artifact and intraluminal assessment. Conclusions The BFDS has adequate visualization on X-ray/fluoroscopy and should be clinically acceptable for fluoroscopic deployment. On MRI, there is less quantitative artifact as well as overall improved qualitative assessment that will allow for more detailed non-invasive imaging follow-up of treated aneurysms, potentially reducing the need for digital subtraction catheter angiography.
引用
收藏
页码:660 / 667
页数:8
相关论文
共 17 条
[1]   Bailout Strategies and Complications Associated with the Use of Flow-Diverting Stents for Treating Intracranial Aneurysms [J].
Al-Mufti, Fawaz ;
Cohen, Eric R. ;
Amuluru, Krishna ;
Patel, Vikas ;
El-Ghanem, Mohammad ;
Nuoman, Rolla ;
Majmundar, Neil ;
Dangayach, Neha S. ;
Meyers, Philip M. .
INTERVENTIONAL NEUROLOGY, 2019, 8 (01) :38-54
[2]  
[Anonymous], 2020, F64020 ASTM, DOI [10.1520/F0640-20, DOI 10.1520/F0640-20]
[3]  
[Anonymous], 2013, F211907 ASTM, DOI DOI 10.1520/F2119-07R13
[4]  
Beuing T, 2021, CURR DIRECT BIOMED E, V2, P533
[5]   Treatment of the femoropopliteal artery with the bioresorbable REMEDY stent [J].
Bontinck, Jan ;
Goverde, Peter ;
Schroe, Herman ;
Hendriks, Jeroen ;
Maene, Lieven ;
Vermassen, Frank .
JOURNAL OF VASCULAR SURGERY, 2016, 64 (05) :1311-1319
[6]   Flow-area relationship in internal carotid and vertebral arteries [J].
Cebral, J. R. ;
Castro, M. A. ;
Putman, C. M. ;
Alperin, N. .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (05) :585-594
[7]   A novel self-expanding primarily bioabsorbable braided flow-diverting stent for aneurysms: initial safety results [J].
Jamshidi, Mehdi ;
Rajabian, Mahmoud ;
Avery, Michael B. ;
Sundararaj, Uttandaraman ;
Ronsky, Janet ;
Belanger, Brooke ;
Wong, John H. ;
Mitha, Alim P. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (07) :700-705
[8]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO
[9]  
2-J
[10]  
Krishna Chandan, 2014, Methodist Debakey Cardiovasc J, V10, P214, DOI 10.14797/mdcj-10-4-214