Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery

被引:110
作者
Findl, O
Kriechbaum, K
Sacu, S
Kiss, B
Polak, K
Nepp, J
Schild, G
Rainer, G
Maca, S
Petternel, V
Lackner, B
Drexler, W
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Ophthalmol, Vienna, Austria
关键词
D O I
10.1016/S0886-3350(03)00243-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare measurements performed with the IOLMaster (Carl Zeiss, Meditec AG) with those obtained by applanation ultrasound (US) and manual keratometry and to evaluate the effect of operator experience on US biometry. Setting: Department of Ophthalmology, University of Vienna, Vienna, Austria. Methods: The axial length (696 eyes) and anterior chamber depth (ACD) (462 eyes) were measured in 377 patients with cataract using the IOLMaster and applanation US. To assess the effect of operator experience on the biometric results, the operators were divided into 2 groups: experienced and less experienced in performing US biometry. The difference in measurements between the methods and the variability of the difference were compared between the 2 groups. Results: Applanation US measured axial length and ACD shorter than the IOLMaster; the mean numerical difference was 0.13 mm and 0.19 mm, respectively (P<.01). For axial length, the absolute difference was smaller with experienced operators than with less experienced operators (0.15 mm versus 0.22 mm) (P<.01). For ACID, experienced operators obtained a smaller difference between measurement techniques (0.21 mm versus 0.29 mm; P<.05). Conclusions: Experienced US operators had less difference and lower variability in the difference between applanation US and IOLMaster readings for axial length and ACD measurements. The noncontact optical method, which is essentially operator independent, gave significantly more reliable biometry before cataract surgery, especially in the case of less experienced operators. (C) 2003 ASCRS and ESCRS
引用
收藏
页码:1950 / 1955
页数:6
相关论文
共 14 条
[1]  
BINKHORST RD, 1981, OPHTHALMIC SURG LAS, V12, P363
[2]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[3]  
Fercher A. F., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V658, P48, DOI 10.1117/12.938523
[4]   EYE-LENGTH MEASUREMENT BY INTERFEROMETRY WITH PARTIALLY COHERENT-LIGHT [J].
FERCHER, AF ;
MENGEDOHT, K ;
WERNER, W .
OPTICS LETTERS, 1988, 13 (03) :186-188
[5]  
HAIGIS W, 2000, OPHTHALMO CHIRURG, V12, P75
[6]  
HITZENBERGER CK, 1993, INVEST OPHTH VIS SCI, V34, P1886
[7]   Biometry of cataractous eyes using partial coherence interferometry - Clinical feasibility study of a commercial prototype I [J].
Kiss, B ;
Findl, O ;
Menapace, R ;
Wirtitsch, M ;
Drexler, W ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :224-229
[8]   Refractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometry - Clinical feasibility study of a commercial prototype II [J].
Kiss, B ;
Findl, O ;
Menapace, R ;
Wirtitsch, M ;
Petternel, V ;
Drexler, W ;
Rainer, G ;
Georgopoulos, M ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :230-234
[9]   Practice styles and preferences of ASCRS members - 1999 survey [J].
Leaming, DV .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06) :913-921
[10]   SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION [J].
OLSEN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02) :125-129