Novel pilot protection principle for high-voltage direct current transmission lines based on fault component current characteristics

被引:55
作者
Gao, Shuping [1 ]
Song, Guobing [2 ]
Ma, Zhibin [2 ]
Jin, Xingfu [2 ]
机构
[1] Xian Univ Sci & Technol, Coll Elect & Control, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Coll Elect Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
HVDC power transmission; power transmission lines; fault currents; power transmission protection; high-voltage direct current transmission lines; fault component current characteristics; HVDC transmission line; transient fault current characteristics; pilot protection principle; sampling frequency; HVDC; SYSTEM;
D O I
10.1049/iet-gtd.2014.0313
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For high-voltage direct current (HVDC) transmission systems, the transient fault current characteristics are that: if the fault point is over the line, the fault component current measured at both converter stations would be increased and they have the same changing direction. If the fault point is beyond the line, the fault component current measured at one converter station is increasing and the fault component current measured at the other converter station is decreasing, so they have the opposite changing direction. According to this characteristic, a novel pilot protection principle for HVDC transmission line based on fault component current is proposed here. The principle proposed has no limitation to the sampling frequency. A fault, whether it occurs in the line or beyond the line, can be effectively identified only using the fault component current at both converter stations. At the same time, the setting criterion of the fault component current is also given. The simulation results show that the new method can identify the faults reliably and rapidly. The study is promising to have significant theoretical and practical value.
引用
收藏
页码:468 / 474
页数:7
相关论文
共 12 条
[1]   Hybrid HVDC system for power transmission to island networks [J].
Andersen, BR ;
Xu, L .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1884-1890
[2]   A new non-communication protection technique for transmission lines [J].
Bo, ZQ .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) :1073-1078
[3]  
Gao Shuping, 2010, Automation of Electric Power Systems, V34, P45
[4]   Generation re-dispatch algorithm against voltage collapse in Jeju island system with a frequency control by high-voltage direct current [J].
Lee, B. ;
Kang, S. -G. ;
Seo, S. ;
Ajjarapu, V. ;
Song, H. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2010, 4 (05) :609-619
[5]   Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line [J].
Liu, Xiaolei ;
Osman, A. H. ;
Malik, O. P. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (02) :569-578
[6]   Frequency domain based control design for an HVdc converter connected to a weak AC network [J].
O'Reilly, J ;
Wood, AR ;
Osauskas, CM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (03) :1028-1033
[7]   Distance Protection for HVDC Transmission Lines Considering Frequency-Dependent Parameters [J].
Suonan, Jiale ;
Zhang, Jiankang ;
Jiao, Zaibin ;
Yang, Liming ;
Song, Guobing .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) :723-732
[8]   A Novel Fault-Location Method for HVDC Transmission Lines [J].
Suonan, Jiale ;
Gao, Shuping ;
Song, Guobing ;
Jiao, Zaibin ;
Kang, Xiaoning .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :1203-1209
[9]   NEW PROTECTION METHOD FOR HVDC LINES INCLUDING CABLES [J].
TAKEDA, H ;
AYAKAWA, H ;
TSUMENAGA, M ;
SANPEI, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (04) :2035-2039
[10]  
Yang Byeongmo, 2006, Journal of Electrical Engineering & Technology, V1, P23