A novel method to assess the incident angle and the LET of protons using a compact single-layer Timepix detector

被引:17
作者
Nabha, R. [1 ,2 ]
Van Hoey, O. [1 ]
Granja, C. [3 ]
Parisi, A. [1 ]
De Saint-Hubert, M. [1 ]
Struelens, L. [1 ]
Oancea, C. [3 ,4 ]
Sterpin, E. [2 ,5 ]
Zach, V. [6 ]
Stursa, J. [6 ]
Rucinski, A. [7 ]
Gajewski, J. [7 ]
Stasica, P. [7 ]
Vanhavere, F. [1 ,2 ]
机构
[1] Belgian Nucl Res Ctr, Radiat Protect Dosimetry & Calibrat Expert Grp, SCK CEN, Mol, Belgium
[2] Katholieke Univ Leuven, Dept Oncol, Lab Expt Radiotherapy, Leuven, Belgium
[3] ADVACAM, Prague, Czech Republic
[4] Univ Bucharest, Bucharest, Romania
[5] UCLouvain, Inst Rech Expt & Clin, MIRO Lab, Brussels, Belgium
[6] Czech Acad Sci, Nucl Phys Inst, Rez, Czech Republic
[7] Polish Acad Sci, Inst Nucl Phys, Krakow, Poland
关键词
Timepix; Protons; LET; Particle therapy; Directional detection; Particle tracking; Semiconductor pixel detector; CARBON ION-BEAMS; LINEAR-ENERGY-TRANSFER; PIXEL DETECTOR; MONTE-CARLO; BIOLOGICAL EFFECTIVENESS; RADIATION; MEDIPIX2; VISUALIZATION; PARTICLES; TRACKING;
D O I
10.1016/j.radphyschem.2022.110349
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Particle therapy can largely benefit from the detailed and wide-range spectrometric and directional characterization of energetic charged particles provided by compact Timepix detectors. Among several physical quantities that can be derived, the assessment of the linear energy transfer (LET) which is based on the deposited energy and particle's track length remains challenging. Due to the detector's pixel pitch, sensor thickness and charge sharing effect, an accurate estimation of the particle's incident angle and hence the track length, has been limited to particles with incident angles greater than 20 with respect to the normal of the sensor layer. This is critical for clinical beams which are highly directional, and measurements with radiation detectors are generally performed with sensitive volumes orthogonally placed with respect to the beam direction. In this work, we present a novel method in which we exploit the morphological cluster parameters to derive the proton's incident angle, thus enabling a precise directional reconstruction over the full field-of-view 2 pi (solid angle), and within 2 from the reference angles for Timepix detectors with 300 and 500 mu m thick Si sensors. As a consequence, the calculation of the track length was also improved, resulting in a more precise LET estimation. The experimental LET spectra and the frequency-averaged LET (LETF) were compared against Monte Carlo simulations using TOPAS for a wide range of proton energies (12 MeV-200 MeV) and incident angles (0-85 & DEG;). An agreement within 12% was found between measured and simulated LETF. A comparison with LET values based on the PSTAR database also showed an agreement within 10%. We demonstrated the feasibility of a precise LET calculation and directional response with an improved angular resolution down to normal incidence using a single-layer Timepix detector, while avoiding the use of a stacked telescope array.
引用
收藏
页数:11
相关论文
共 61 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], 2010, NUCL INSTRUM METH B, DOI DOI 10.1016/J.NIMB.2010.02.091
[3]   Measurement of the efficiency of the pattern recognition of tracks generated by ionizing radiation in a TIMEPIX detector [J].
Asbah, N. ;
Leroy, C. ;
Pospisil, S. ;
Soueid, P. .
JOURNAL OF INSTRUMENTATION, 2014, 9
[4]  
Attix F.H., 2008, Introduction to Radiological Physics and Radiation Domisetry
[5]  
Berger M J, 2005, 4999 NISTIR
[6]   STRAGGLING IN THIN SILICON DETECTORS [J].
BICHSEL, H .
REVIEWS OF MODERN PHYSICS, 1988, 60 (03) :663-699
[7]   Medipix2 as a tool for proton beam characterization [J].
Bisogni, M. G. ;
Cirrone, G. A. P. ;
Cuttone, G. ;
Del Guerra, A. ;
Lojacono, P. ;
Piliero, M. A. ;
Romano, F. ;
Rosso, V. ;
Sipala, V. ;
Stefanini, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) :48-50
[8]  
Bisogni M.G., 2008, SILICON PIXEL DETECT, P362, DOI [10.1109/ nssmic.2008.4775186, DOI 10.1109/NSSMIC.2008.4775186]
[9]   Study of the charge sharing in a silicon pixel detector by means of α-particles interacting with a Medipix2 device [J].
Campbell, M. ;
Heijne, E. ;
Holy, T. ;
Idarraga, J. ;
Jakubek, J. ;
Lebel, C. ;
Leroy, C. ;
Llopart, X. ;
Pospisil, S. ;
Tlustos, L. ;
Vykydal, Z. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) :38-41
[10]   A critical study of different Monte Carlo scoring methods of dose average linear-energy-transfer maps calculated in voxelized geometries irradiated with clinical proton beams [J].
Cortes-Giraldo, M. A. ;
Carabe, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (07) :2645-2669