Comparison Study of Doppler Ultrasound Surveillance of Expanded Polytetrafluoroethylene-Covered Stent versus Bare Stent in Transjugular Intrahepatic Portosystemic Shunt

被引:33
|
作者
Huang, Qian [1 ]
Wu, Xingjiang [1 ]
Fan, Xinxin [1 ]
Cao, Jianmin [1 ]
Han, Jianming [1 ]
Xu, Lin [1 ]
Li, Ning [1 ]
机构
[1] Jinling Hosp, Res Inst Gen Surg, Nanjing, Peoples R China
关键词
transjugular intrahepatic portosystemic shunt; e-PTFE covered stent; Doppler ultrasound; hemodynamics; PATENCY; TIPS; SONOGRAPHY; ULTRASONOGRAPHY; PREVENTION; CREATION; TRIAL; GRAFT;
D O I
10.1002/jcu.20709
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. This prospectively randomized controlled study aimed to assess with Doppler ultrasound (US) the shunt function of expanded polytetrafluoroethylene (ePTFE)-covered transjugular intrahepatic portosystemic shunt (TIPS) stent versus bare stent and to evaluate the usefulness of routine TIPS follow-up of ePTFE-covered stents. Methods. Sixty consecutive patients were randomized for bare or covered transjugular TIPS stenting in our institution between April 2007 and April 2009. Data of follow-up Doppler US, angiography, and portosystemic pressure gradient measurements were collected and analyzed. Results. The follow-up period was 8.34 +/- 4.42 months in the bare-stent group and 6.16 +/- 3.89 months in the covered-stent group. Baseline clinical characteristics were similar in both groups. Two hundred three US studies were performed in 60 patients, with a mean of 3.4 per patient, and demonstrated abnormalities in 28 patients (21 bare stents, 7 ePTFE-covered stents), 19 of them (13 in bare-stent group, 6 in covered-stent group) showing no clinical evidence of recurrence. Ten of 13 patients in the bare-stent group underwent balloon angioplasty or additional stent placement, whereas only one of six patients in the covered-stent group needed reintervention for intimal hyperplasia. The average peak velocity in the midshunt of ePTFE-covered stent was 139 +/- 26 cm/s after TIPS creation and 125 +/- 20 cm/s during follow-up, which was significantly higher than the bare-stent group (p < 0.05). The main portal vein and hepatic artery showed higher flow velocities in the ePTFE-covered stent group than in the bare-stent group. ePTFE-covered stents maintained lower portosystemic pressure gradient than bare stents (9.5 +/- 2.9 versus 13.2 +/- 1.5 mmHg, p < 0.05). Conclusions. ePTFE-covered stents resulted in higher patency rates and better hemodynamics than bare stents. Routine US surveillance may not be necessary in patients with ePTFE-covered TIPS stent. (C) 2010 Wiley Periodicals, Inc. J Clin Ultrasound 38:353-360, 2010; Published online in Wiley InterScience (www. interscience.wiley.com). DOI: 10.1002/jcu.20709
引用
收藏
页码:353 / 360
页数:8
相关论文
共 50 条
  • [1] Transjugular intrahepatic portosystemic shunt using the FLUENCY expanded polytetrafluoroethylene-covered stent
    Wu, Qinghua
    Jiang, Jianwei
    He, Yujie
    Jiang, Tianpeng
    Zhou, Shi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (01) : 263 - 266
  • [2] Prognostic Factors for Acute Transjugular Intrahepatic Portosystemic Shunt Occlusion Using Expanded Polytetrafluoroethylene-Covered Stent
    Wang, Xiaoze
    Luo, Xuefeng
    Zhao, Ming
    Song, Jinlei
    Li, Xiao
    Yang, Li
    DIGESTIVE DISEASES AND SCIENCES, 2020, 65 (10) : 3032 - 3039
  • [3] Polytetrafluoroethylene-Covered Stent Graft Versus Bare Stent in Transjugular Intrahepatic Portosystemic Shunt: Systematic Review and Meta-Analysis
    Triantafyllou, Tania
    Aggarwal, Piyush
    Gupta, Ekansh
    Svetanoff, Wendy Jo
    Bhirud, Deepak Prakash
    Singhal, Saurabh
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2018, 28 (07): : 867 - 879
  • [4] Long-Term Patency and Clinical Analysis of Expanded Polytetrafluoroethylene-Covered Transjugular Intrahepatic Portosystemic Shunt Stent Grafts
    Weber, Charles N.
    Nadolski, Gregory J.
    White, Sarah B.
    Clark, Timothy W. I.
    Mondschein, Jeffrey I.
    Stavropoulos, S. William
    Shlansky-Goldberg, Richard D.
    Trerotola, Scott O.
    Soulen, Michael C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (09) : 1257 - 1265
  • [5] Prognostic Factors for Acute Transjugular Intrahepatic Portosystemic Shunt Occlusion Using Expanded Polytetrafluoroethylene-Covered Stent
    Xiaoze Wang
    Xuefeng Luo
    Ming Zhao
    Jinlei Song
    Xiao Li
    Li Yang
    Digestive Diseases and Sciences, 2020, 65 : 3032 - 3039
  • [6] Influence of the Secondary Deployment of Expanded Polytetrafluoroethylene-covered Stent Grafts on Maintenance of Transjugular Intrahepatic Portosystemic Shunt Patency
    Jirkovsky, Vaclav
    Fejfar, Tomas
    Safka, Vaclav
    Hulek, Petr
    Krajina, Antonin
    Chovanec, Vendelin
    Raupach, Jan
    Lojik, Miroslav
    Vanasek, Tomas
    Renc, Ondrej
    Ali, Shahzad M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (01) : 55 - 60
  • [7] Comparison of specialized stent versus generic stent and bare stent combination for transjugular intrahepatic portosystemic shunt creation
    Bai, Yaowei
    Liu, Jiacheng
    Wang, Chaoyang
    Yao, Wei
    Ju, Shuguang
    Wang, Yingliang
    Zhou, Chen
    Dong, Xiangjun
    Zheng, Chuansheng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [8] Clinical Efficacy of Transjugular Intrahepatic Portosystemic Shunt Created with Expanded Polytetrafluoroethylene-Covered Stent-Grafts: 8-mm Versus 10-mm
    Luo, Xuefeng
    Wang, Xiaoze
    Zhu, Yongjun
    Xi, Xiaotan
    Zhao, Ying
    Yang, Jinlin
    Li, Xiao
    Yang, Li
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (05) : 737 - 743
  • [9] A novel endovascular adjustable polytetrafluoroethylene-covered stent for the management of hepatic encephalopathy after transjugular intrahepatic portosystemic shunt
    Weintraub, Joshua L.
    Mobley, David G.
    Weiss, Michael E.
    Swanson, Eli
    Kothary, Nishita
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (04) : 563 - 566
  • [10] Comparison of outcomes for transjugular intrahepatic portosystemic shunt creation: Viatorr versus Fluency versus a bare stent/Fluency stent combination
    Li, Weizhi
    Liu, Mengying
    Guan, Sheng
    Ding, Pengxu
    Yuan, Jia
    Zhao, Yan
    Li, Peijie
    Ma, Fuquan
    Xue, Hui
    CVIR ENDOVASCULAR, 2024, 7 (01)