Application of a liquid chromatography tandem mass spectrometry method to the analysis of water-soluble vitamins in Italian pasta

被引:76
作者
Leporati, A
Catellani, D
Suman, M
Andreoli, R
Manini, P
Niessen, WMA
机构
[1] Barilla GR F Lli SpA, R&D, Cent Res Lab, I-43100 Parma, Italy
[2] Univ Parma, Lab Ind Toxicol, I-43100 Parma, Italy
[3] Hyphen MassSpec Consultancy, NL-2332 XT Leiden, Netherlands
关键词
water-soluble vitamins; pyridoxine; pyridoxal; pyridoxamine; nicotinamide; nicotinic acid; pantothenic acid; folic acid; LC-MS/MS; Italian pasta; fortified food;
D O I
10.1016/j.aca.2004.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of several water-soluble vitamins, namely vitamins B-1, B-2, B-6 (pyridoxine, pyridoxal, and pyridoxamine), and PP (nicotinamide and nicotinic acid), pantothenic acid, and folic acid was developed and validated. The analytes were characterized by means of their electrospray (ESI) and atmospheric pressure chemical ionization (APCI) mass spectra. In general, the positive ion spectra were 100- to 1000-fold more intense than the corresponding negative ion ones. Chromatography of water-soluble vitamins was obtained by using a reversed-phase C 16 Amide (15 cm, 5 mu m) column and a mobile phase made of ammonium formate buffer (20 mM, pH 3.75)/methanol under gradient elution conditions. Linearity of the MS response was observed over three to four orders for both ESI and APCI, and limits of detection were in the low mu g/l range for both the ionization techniques. In particular, the sensitivity of ESI was about two- to five-fold higher for all vitamins except PP vitamers, for which APCI produced a better response. Precision calculated at two concentration levels (0.05 and 1.0 mg/l) was within 0.2-7.4% for all intra- and inter-day determinations and for all analytes. The LC-ESI-MS/MS method was applied to the quantitative analysis of the natural content of vitamins in typical Italian pasta samples, as well as in fortified pasta samples produced for the US market. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 19 条
[11]   FORMIC-ACID AMMONIUM FORMATE BUFFER SYSTEM FOR THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
IIDA, J ;
MURATA, T .
ANALYTICAL SCIENCES, 1990, 6 (02) :269-272
[12]   APPLICATION OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY TO THE ANALYSIS OF WATER-SOLUBLE VITAMINS [J].
IIDA, J ;
MURATA, T .
ANALYTICAL SCIENCES, 1990, 6 (02) :273-276
[13]  
JACOBY BT, 1992, J AOAC INT, V75, P891
[14]  
KALMAN A, 2003, NEW FOOD, V4, P26
[15]   Determination of vitamin B5 in a range of fortified food products by reversed-phase liquid chromatography-mass spectrometry with electrospray ionisation [J].
Mittermayr, R ;
Kalman, A ;
Trisconi, MJ ;
Heudi, O .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) :1-6
[16]   A quantitative stable-isotope LC-MS method for the determination of folic acid fortified foods [J].
Pawlosky, RJ ;
Flanagan, VP .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) :1282-1286
[17]  
REES DI, 1989, J MICRONUTR ANAL, V5, P53
[18]   CHROMATOGRAPHIC DETERMINATION OF VITAMINS IN FOODS [J].
RIZZOLO, A ;
POLESELLO, S .
JOURNAL OF CHROMATOGRAPHY, 1992, 624 (1-2) :103-152
[19]  
WEHRMANN J, 2000, FOOD TEST ANAL, V6, P15