Flat-Panel CT Arthrography Feasibility Study and Comparison to Multidetector CT Arthrography

被引:17
作者
Guggenberger, Roman [1 ]
Fischer, Michael Alexander [1 ]
Hodler, Juerg [1 ]
Pfammatter, Thomas [1 ]
Andreisek, Gustav [1 ]
机构
[1] Univ Zurich Hosp, Dept Radiol, Musculoskeletal Imaging Res Grp, CH-8091 Zurich, Switzerland
关键词
flat-panel CT; arthrography; cone-beam CT; COMPUTED-TOMOGRAPHY ARTHROGRAPHY; TRABECULAR STRUCTURE-ANALYSIS; DIAGNOSTIC-ACCURACY; IMAGE QUALITY; DETECTOR CT; VOLUME CT; NOISE; MDCT; AGREEMENT;
D O I
10.1097/RLI.0b013e3182419082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To show the feasibility of flat-panel computed tomography (FPCT) arthrography and quantitatively and qualitatively compare different FPCT protocols with standard multidetector computed tomography (MDCT). Materials and Methods: First, a phantom simulating joint space with increasing iodine concentrations was scanned using a standard MDCT and 3 different FPCT protocols. Quantitative analyses were performed by measuring CT numbers of iodine dilutions, radiation dose, and image noise as well as signal-to-noise ratio and contrast-to-noise ratio. Second, FPCT arthrographies of 4 animal joint specimens were performed and analyzed qualitatively by 2 independent readers who evaluated image artifacts, image noise, overall image quality and anatomic depiction of bone, cartilage, and soft tissue. Kappa values were calculated for inter-reader agreement. Pearson's correlation coefficient (r) and Wilcoxon signed-ranks test with Bonferroni corrections for multiple comparisons were used to compare MDCT and FPCT. Results: In phantoms, all CT scans showed a linear correlation between increasing iodine concentrations and mean HU values of contrast media and radiation dose, respectively (r = 0.98-0.99, P < 0.01). Dose-length product remained constant for MDCT scans. Signal-to-noise ratio for phantom water linearly decreased in all FPCT scans with increasing iodine concentrations. Contrast-to-noise ratio curves showed reduced slope at iodine concentrations higher than 75 mg/mL. FPCT arthrography after intra-articular administration of 5 to 6 mL of a 25% dilution of iopromide (Ultravist 300 mg/mL, Bayer HealthCare, Berlin, Germany) was successfully performed in all 4 animal joint specimens. Kappa values for inter-reader agreement of qualitative image analyses were 0.62 to 0.91. Image and depiction quality of 20-s FPCT scans were similar or superior compared with standard MDCT (P < 0.005). Conclusion: FPCT arthrography is feasible and may allow similar image quality compared with standard MDCT arthrography.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
[31]   A comparison of CT arthrography of the wrist to findings during wrist arthroscopy [J].
Bille, Brian ;
Harley, Brian ;
Cohen, Hal .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (06) :834-841
[32]   Flat panel CT versus multidetector CT in skull base imaging: are there differences in image quality? [J].
Schulze, Maximilian ;
Hirt, Bernhard ;
Reimann, Katrin .
HEAD & FACE MEDICINE, 2023, 19 (01)
[33]   Novel flat-panel cone-beam CT compared to multi-detector CT for assessment of acute ischemic stroke: A prospective study [J].
Nicholson, Patrick ;
Cancelliere, Nicole M. ;
Bracken, John ;
Hummel, Erik ;
van Nijnatten, Fred ;
Withagen, Paul ;
van de Haar, Peter ;
Hallacoglu, Bertan ;
van Vlimmeren, Marijke ;
Agid, Ronit ;
Krings, Timo ;
Pereira, Vitor Mendes .
EUROPEAN JOURNAL OF RADIOLOGY, 2021, 138
[34]   Diagnostic evaluation of open knee injuries: a comparison of arthrography and CT scans [J].
Taweekitikul, Pariwat ;
Chatthammarak, Sutthisak ;
Hongsmatip, Patcharee ;
Leelasestaporn, Techit ;
Ongkanchana, Chavithorn ;
Jiamton, Chittawee .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 35 (01)
[35]   Performance of cone beam CT using a flat-panel imager [J].
Endo, M ;
Tsunoo, T ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M ;
Fukuda, Y .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :815-821
[36]   Optimizing joint-imaging: (CT)-arthrography [J].
Obermann, WR .
EUROPEAN RADIOLOGY, 1996, 6 (03) :275-283
[37]   Verbesserte radiologische Darstellung kongenitaler Auralatresien mittels ,,flat-panel volume CT" [J].
Mueller-Graff, Franz-Tassilo ;
von Duering, Jan ;
Voelker, Johannes ;
Al-Tinawi, Fadi ;
Hagen, Rudolf ;
Neun, Tilmann ;
Hackenberg, Stephan ;
Rak, Kristen .
HNO, 2024, 72 (11) :815-824
[38]   Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance [J].
Lambros Tselikas ;
Julien Joskin ;
Florian Roquet ;
Geoffroy Farouil ;
Serge Dreuil ;
Antoine Hakimé ;
Christophe Teriitehau ;
Anne Auperin ;
Thierry de Baere ;
Frederic Deschamps .
CardioVascular and Interventional Radiology, 2015, 38 :167-176
[39]   Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance [J].
Tselikas, Lambros ;
Joskin, Julien ;
Roquet, Florian ;
Farouil, Geoffroy ;
Dreuil, Serge ;
Hakime, Antoine ;
Teriitehau, Christophe ;
Auperin, Anne ;
de Baere, Thierry ;
Deschamps, Frederic .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) :167-176
[40]   High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo [J].
Sonnow, L. ;
Koennecker, S. ;
Luketina, R. ;
Werncke, T. ;
Hinrichs, J. B. ;
Meyer, B. C. ;
Wacker, F. K. ;
von Falck, C. .
EUROPEAN RADIOLOGY, 2019, 29 (06) :3233-3240