In vivo liver tracking with a high volume rate 4D ultrasound scanner and a 2D matrix array probe

被引:48
作者
Bell, Muyinatu A. Lediju [1 ,2 ,3 ]
Byram, Brett C. [3 ]
Harris, Emma J. [1 ,2 ]
Evans, Philip M. [1 ,2 ]
Bamber, Jeffrey C. [1 ,2 ]
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5NG, Surrey, England
[2] Royal Marsden Hosp, Sutton SM2 5NG, Surrey, England
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
基金
英国工程与自然科学研究理事会;
关键词
REAL-TIME TUMOR; SPECKLE TRACKING; ORGAN MOTION; RADIATION-THERAPY; RADIOTHERAPY; PERFORMANCE; REPRODUCIBILITY; DISPLACEMENT; FEASIBILITY; RESPIRATION;
D O I
10.1088/0031-9155/57/5/1359
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effectiveness of intensity-modulated radiation therapy (IMRT) is compromised by involuntary motion (e.g. respiration, cardiac activity). The feasibility of processing ultrasound echo data to automatically estimate 3D liver motion for real-time IMRT guidance was previously demonstrated, but performance was limited by an acquisition speed of 2 volumes per second due to hardware restrictions of a mechanical linear array probe. Utilizing a 2D matrix array probe with parallel receive beamforming offered increased acquisition speeds and an opportunity to investigate the benefits of higher volume rates. In vivo livers of three volunteers were scanned with and without respiratory motion at volume rates of 24 and 48 Hz, respectively. Respiration was suspended via voluntary breath hold. Correlation-based, phase-sensitive 3D speckle tracking was applied to consecutively acquired volumes of echo data. Volumes were omitted at fixed intervals and 3D speckle tracking was reapplied to study the effect of lower scan rates. Results revealed periodic motion that corresponded with the heart rate or breathing cycle in the absence or presence of respiration, respectively. For cardiac-induced motion, volume rates for adequate tracking ranged from 8 to 12 Hz and was limited by frequency discrepancies between tracking estimates from higher and lower frequency scan rates. Thus, the scan rate of volume data acquired without respiration was limited by the need to sample the frequency induced by the beating heart. In respiratory-dominated motion, volume rate limits ranged from 4 to 12 Hz, interpretable from the root-mean-squared deviation (RMSD) from tracking estimates at 24 Hz. While higher volume rates yielded RMSD values less than 1 mm in most cases, lower volume rates yielded RMSD values of 2-6 mm.
引用
收藏
页码:1359 / 1374
页数:16
相关论文
共 38 条
[1]  
Akiyama I., 1988, ACOUST IMAG, V17, P499
[2]   Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing [J].
Balter, JM ;
TenHaken, RK ;
Lawrence, TS ;
Lam, KL ;
Robertson, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01) :167-174
[3]  
Bamber JC, 1996, ACOUST IMAGING, P239
[4]   Calibration of three-dimensional ultrasound images for image-guided radiation therapy [J].
Bouchet, LG ;
Meeks, SL ;
Goodchild, G ;
Bova, FJ ;
Buatti, JM ;
Friedman, WA .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :559-577
[5]   3-D Phantom and In Vivo Cardiac Speckle Tracking Using a Matrix Array and Raw Echo Data [J].
Byram, Brett C. ;
Holley, Greg ;
Giannantonio, Doug M. ;
Trahey, Gregg E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (04) :839-854
[6]   INTERFRACTION AND INTRAFRACTION CHANGES IN AMPLITUDE OF BREATHING MOTION IN STEREOTACTIC LIVER RADIOTHERAPY [J].
Case, Robert B. ;
Moseley, Douglas J. ;
Sonke, Jan Jakob ;
Eccles, Cynthia L. ;
Dinniwell, Robert E. ;
Kim, John ;
Bezjak, Andrea ;
Milosevic, Michael ;
Brock, Kristy K. ;
Dawson, Laura A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03) :918-925
[7]   ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN [J].
DAVIES, SC ;
HILL, AL ;
HOLMES, RB ;
HALLIWELL, M ;
JACKSON, PC .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1096-1102
[8]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[9]   A freehand elastographic imaging approach for clinical breast imaging: System development and performance evaluation [J].
Doyley, MM ;
Bamber, JC ;
Fuechsel, F ;
Bush, NL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) :1347-1357
[10]   Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy [J].
Eccles, C ;
Brock, KK ;
Bissonnette, JP ;
Hawkins, M ;
Dawson, LA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (03) :751-759