Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography

被引:16
|
作者
Wong, Sophia S. [1 ]
Vuong, Vivian S. [1 ]
Cunefare, David [2 ]
Farsiu, Sina [2 ,3 ]
Moshiri, Ala [1 ]
Yiu, Glenn [1 ]
机构
[1] Univ Calif Davis, Dept Ophthalmol, 4860 Y St,Suite 2400, Sacramento, CA 95817 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[3] Duke Univ, Dept Ophthalmol, Durham, NC USA
关键词
RETINAL VEIN OCCLUSION; CENTRAL SEROUS CHORIORETINOPATHY; GROWTH-FACTOR THERAPY; DIABETIC-RETINOPATHY; PANRETINAL PHOTOCOAGULATION; NORMAL EYES; REPEATABILITY; DEGENERATION; EDEMA;
D O I
10.1016/j.ajo.2017.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine if different types of retinal fluid in the central macula affect the reproducibility of choroidal thickness (CT) measurements on enhanced depth imaging optical coherence tomography (EDI-OCT). DESIGN: Retrospective reliability analysis. METHODS: EDI-OCT images were obtained and the choroidal-scleral junction was analyzed through semiautomated segmentation. CT was measured at the fovea and averaged across the central 3-mm horizontal segment. Demographic data, central macular thickness, and type of fluid present were recorded. Intragrader and intergrader repeatability were assessed using the intraclass correlation coefficient (ICC) and coefficient of repeatability (CR). RESULTS: Of 124 eyes analyzed, 60 (48.4%) had diabetic macular edema, 32 (25.8%) had neovascular age-related macular degeneration, and 32 (25.8%) had other causes of fluid. Intergrader ICC (CR) was 0.95 (74.1 mu m) and 0.96 (63.9 mu m) for subfoveal and average CT, respectively. CR was similar across various causes of retinal fluid, but was worst for subretinal fluid compared to intraretinal or sub-retinal pigment epithelial fluid. CR also worsened with increasing choroidal thickness, but was not affected by retinal thickness. Intragrader repeatability was generally greater than intergrader values, and followed the same trend. CONCLUSIONS: The presence of macular fluid reduces CT measurement reproducibility, particularly in eyes with subretinal fluid and greater choroidal thickness. A difference of 74.1 mu m in subfoveal CT or 63.9 pm in average CT may be necessary to detect true clinical change in eyes with macular fluid. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [41] Reproducibility of Optical Coherence Tomography Measurements in Children
    Altemir, Irene
    Pueyo, Victoria
    Elia, Noemi
    Polo, Vicente
    Larrosa, Jose M.
    Oros, Daniel
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (01) : 171 - 176
  • [42] Evaluation of the macular choroidal thickness using spectral optical coherence tomography in patients with obstructive sleep apnoea syndrome
    Bayhan, Hasan A.
    Bayhan, Seray Aslan
    Intepe, Yavuz S.
    Muhafiz, Ersin
    Gurdal, Canan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (02) : 139 - 144
  • [43] Comparison of choroidal vessel thickness in children and adult eyes by enhanced-depth imaging optical coherence tomography imaging
    Hanumunthadu, Daren
    Ruiz-Medrano, Jorge
    Dumpala, Sunila
    Jabeen, Ayesha
    Jabeen, Asiya
    Goud, Abhilash
    Ruiz-Moreno, Jose M.
    Chhablani, Jay
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (04) : 681 - 686
  • [44] Comparison of choroidal thickness measurements between spectral domain optical coherence tomography and swept source optical coherence tomography in children
    Lee, Chun On
    Zhang, Xiujuan
    Yuan, Nan
    Tang, Shumin
    Chen, Li Jia
    Cheung, Carol Y.
    Yam, Jason C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [45] Macular Choroidal Thickness and Volume of Eyes With Reticular Pseudodrusen Using Swept-Source Optical Coherence Tomography
    Ueda-Arakawa, Naoko
    Ooto, Sotaro
    Ellabban, Abdallah A.
    Takahashi, Ayako
    Oishi, Akio
    Tamura, Hiroshi
    Yamashiro, Kenji
    Tsujikawa, Akitaka
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (05) : 994 - 1004
  • [46] The Application of Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography in Macular Diseases
    Wang, Jing
    Yin, Lian-Rong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [47] Spectral-Domain Optical Coherence Tomography Measurements of Choroidal Thickness and Outer Retinal Disruption in Macular Telangiectasia Type 2
    Nunes, Renata Portella
    Goldhardt, Raquel
    de Amorim Garcia Filho, Carlos Alexandre
    Thorell, Mariana R.
    Abbey, Ashkan M.
    Kuriyan, Ajay E.
    Modi, Yasha S.
    Shah, Milan
    Yehoshua, Zohar
    Gregori, Giovanni
    Feuer, William
    Rosenfeld, Philip J.
    Ophthalmic Surgery Lasers & Imaging Retina, 2015, 46 (02) : 162 - 170
  • [48] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [49] Measurable Range of Subfoveal Choroidal Thickness With Conventional Spectral Domain Optical Coherence Tomography
    Kong, Mingui
    Choi, Da Ye
    Han, Gyule
    Song, Yun-Mi
    Park, Sung Yong
    Sung, Joohon
    Hwang, Sungsoon
    Ham, Don-Il
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [50] En face enhanced depth imaging optical coherence tomography of polypoidal choroidal vasculopathy
    Semoun, Oudy
    Coscas, Florence
    Coscas, Gabriel
    Lalloum, Franck
    Srour, Mayer
    Souied, Eric H.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) : 1028 - 1034