Progress status of the ITER Vacuum Vessel sectors manufacturing design thermal hydraulic performance

被引:1
作者
Colomer, C. [1 ]
Briani, P. [1 ]
Fradera, J. [1 ]
Ichard, M. [1 ]
Aleman, A. [1 ]
Martinez-Saban, E. [1 ]
Zamora, I. [1 ]
Hermosa, B. [1 ]
Martin, M. [1 ]
Mata, O. [1 ]
Martell, A. [1 ]
Martinez, J. M. [2 ]
Sabourin, F. [2 ]
Martin, A. [2 ]
Cau, F. [3 ]
Caixas, J. [3 ]
Portone, A. [3 ]
机构
[1] IDOM Consulting Engn Architecture SAU, Gran Via Carles 3 97 Baixos, Barcelona 08028, Spain
[2] ITER Org, Route Vinon Sur Verdon,CS 90046, F-13067 St Paul Les Durance, France
[3] Fus Energy F4E, C Josep Pla,2,Edificio B3, E-08019 Barcelona, Spain
关键词
Nuclear fusion ITER; Vacuum Vessel; Thermal hydraulics; CFD; CHT (Conjugate heat transfer);
D O I
10.1016/j.fusengdes.2017.03.095
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The present work exposes the 3D steady state thermal hydraulic (TH) analysis of the Irregular Sector number 3 (IrS#3) of the ITER Vacuum Vessel (VV), including the Irregular Field Joints (IrFJ) by means of a commercial CFD (Computational Fluid Dynamics) code. The geometry of the IrS#3 has been simplified and healed in order to be suitable for CFD analysis. The simplified geometry has been meshed and converted to a polyhedral cell based mesh so as to enhance accuracy and calculation stability. Nuclear heat deposition (H) from the latest C Lite model [1] has been implemented through several User Defined Functions (UDF). Water coolant and stainless steel shell are solved together as a steady state conjugate heat transfer problem in order to assess the impact of the nuclear heat deposition on the IrS#3 cooling scheme. Hence, the IrS#3 is simulated as a whole, without splitting the domain. Results show the total IrS#3 pressure drop as well as the flow and temperature distribution all over the IrS#3. Moreover, the heat transfer coefficient (h) has been calculated at the fluid-solid interface. Velocity magnitude in the water coolant has an average value of 0.10 m/s and mass flow rate distribution is 11% and 89% respectively for Inboard and Outboard. The pressure drop, mainly concentrated at inlet and outlet ducts, is of 77.4 kPa. The average his of 5.690 W/(m(2)K), way above the design limit of 500 W/(m(2)K). The fluid temperature stays at an average value of 101.7 degrees C. The results obtained have a significant importance regarding design and safety and give a valuable insight on the current cooling scheme and system behavior for the IrS#3 of the ITER W. This follows a previous work presenting the methodology and the results of a 3D TH analysis of the Irregular Sector number 2 (IrS#2) of the ITER Vacuum Vessel (W) by means of CFD [2]. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:578 / 581
页数:4
相关论文
共 9 条
[1]  
[Anonymous], 2009, F4E DDD 1 5 VACUUM V
[2]  
Brown B.Forrest, 2009, MCNP5151 LOS AL NAT
[3]  
Fradera J., 2015, THERMAL HYDRAULIC AN
[4]  
IO, 2008, ITER MAT PROP HDB TY
[5]  
Menter F., 1993, ZONAL 2 EQUATION K O, V93-2906
[6]  
NIST, 2016, THERM PROP FLUID SYS
[7]  
Richard LSavoldi, 2013, FUSION ENG DES, V88
[8]  
Salim S, 2009, IMECS, V2
[9]  
Zanino R., 2013, CFD ANAL REGULAR S 2, V8