Advanced exergy analysis on a modified auto-cascade freezer cycle with an ejector

被引:52
作者
Bai, Tao [1 ]
Yu, Jianlin [1 ]
Yan, Gang [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Auto-cascade refrigeration; Freezer; Ejector; Exergy; Advanced exergy analysis; CO2 REFRIGERATION CYCLE; HEAT-PUMP CYCLE; THERMODYNAMIC PERFORMANCE; POWER-PLANT; SYSTEM; OPTIMIZATION; ASSESSMENTS; MIXTURE; ENERGY;
D O I
10.1016/j.energy.2016.07.048
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a study on a modified ejector enhanced auto-cascade freezer cycle with conventional thermodynamic and advanced exergy analysis methods. The energetic analysis shows that the modified cycle exhibits better performance than the conventional auto-cascade freezer cycle, and the system COP and volumetric refrigeration capacity could be improved by 19.93% and 28.42%. Furthermore, advanced exergy analysis is adopted to better evaluate the performance of the proposed cycle. The exergy destruction within a system component is split into endogenous/exogenous and unavoidable/avoidable parts in the advanced exergy analysis. The results show that the compressor with the largest avoidable endogenous exergy destruction has highest improvement priority, followed by the condenser, evaporator and ejector, which is different from the conclusion obtained from the conventional exergy analysis. The evaporator/condenser greatly affects the exogenous exergy destruction within the system components, and the compressor has large impact on the exergy destruction within the condenser. Improving the efficiencies of the compressor efficiency and the ejector could effectively reduce the corresponding avoidable endogenous exergy destruction. The exergy destruction within the evaporator almost entirely belongs to the endogenous part, and reducing the temperature difference at the evaporator is the main approach of reducing its exergy destruction. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:385 / 398
页数:14
相关论文
共 44 条
  • [21] Transcritical CO2 refrigeration cycle with ejector-expansion device
    Li, DQ
    Groll, EA
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 766 - 773
  • [22] Refrigerant conversion of Auto-Refrigerating Cascade (ARC) systems
    Missimer, DJ
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (03): : 201 - 207
  • [23] Comparative evaluation of LNG - based cogeneration systems using advanced exergetic analysis
    Morosuk, T.
    Tsatsaronis, G.
    [J]. ENERGY, 2011, 36 (06) : 3771 - 3778
  • [24] Advanced exergetic evaluation of refrigeration machines using different working fluids
    Morosuk, T.
    Tsatsaronis, G.
    [J]. ENERGY, 2009, 34 (12) : 2248 - 2258
  • [25] Conventional thermodynamic and advanced exergetic analysis of a refrigeration machine using a Voorhees' compression process
    Morosuk, Tatiana
    Tsatsaronis, George
    Zhang, Congyu
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2012, 60 : 143 - 151
  • [26] Performance of an auto refrigerant cascade refrigerator operating in liquid refrigerant supply (LRS) mode with different cascade heat exchangers
    Nayak, H. Gurudath
    Venkatarathnam, G.
    [J]. CRYOGENICS, 2010, 50 (11-12) : 720 - 727
  • [27] Conventional and advanced exergetic analyses applied to a combined cycle power plant
    Petrakopoulou, Fontina
    Tsatsaronis, George
    Morosuk, Tatiana
    Carassai, Anna
    [J]. ENERGY, 2012, 41 (01) : 146 - 152
  • [28] Optimization of ejector-expansion transcritical CO2 heat pump cycle
    Sarkar, Jahar
    [J]. ENERGY, 2008, 33 (09) : 1399 - 1406
  • [29] Exergy and energy analysis of three stage auto refrigerating cascade system using Zeotropic mixture for sustainable development
    Sivakumar, M.
    Somasundaram, P.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 84 : 589 - 596
  • [30] Thermodynamic performance of an auto-cascade ejector refrigeration cycle with mixed refrigerant R32+R236fa
    Tan, Yingying
    Wang, Lin
    Liang, Kunfeng
    [J]. APPLIED THERMAL ENGINEERING, 2015, 84 : 268 - 275