Evaluation of different carbon electrodes for adsorptive stripping analysis of nucleic acids

被引:90
作者
Cai, XH
Rivas, G
Farias, PAM
Shiraishi, H
Wang, J
Palecek, E
机构
[1] ACAD SCI CZECH REPUBL,INST BIOPHYS,CZ-61265 BRNO,CZECH REPUBLIC
[2] PONTIFICIA UNIV CATOLICA RIO DE JANEIRO,DEPT CHEM,RIO JANEIRO,BRAZIL
关键词
nucleic acids; DNA; RNA; nucleic acid oxidation; carbon electrodes; potentiometric stripping analysis;
D O I
10.1002/elan.1140080809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently we have shown (see Ref. [8]) that submicrogram amounts of nucleic acids can be measured by potentiometric stripping analysis (PSA) at carbon paste electrodes. In this article we investigate and compare various carbon electrode materials for use in stripping analysis of nucleic acids. Both the interfacial and redox properties of DNA and RNA are strongly dependent upon the nature of the carbon material and the electrode pretreatment step. In view of the high solvent decomposition background response near the guanine oxidation peak, only potentiometric stripping analysis can be used for convenient quantitation of trace levels (ng/mL) of nucleic acids. The trend in sensitivity: carbon paste > pyrolytic graphite > highly oriented pyrolytic graphite > carbon strip [with detection limits for oligo(dG)(20) of 20, 30, 40 and 50 ng/mL, respectively, using 5 min accumulation]. No response was observed for trace measurements at the glassy carbon or carbon fiber electrodes. The influence of the surface pretreatment and accumulation time is described along with the analytical-performance characteristics at each electrode. Useful information about the adsorption behavior of nucleic acids at different carbon electrodes are also obtained.
引用
收藏
页码:753 / 758
页数:6
相关论文
共 15 条
[1]   OXIDATION OF DEOXYRIBONUCLEIC-ACID AT CARBON ELECTRODES - THE EFFECT OF THE QUALITY OF THE DEOXYRIBONUCLEIC-ACID SAMPLE [J].
BRABEC, V ;
KOUDELKA, J .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1980, 7 (04) :793-805
[2]   ELECTROCHEMICAL BEHAVIOR OF NATURAL AND BIOSYNTHETIC POLYNUCLEOTIDES AT PYROLYTIC-GRAPHITE ELECTRODE A NEW PROBE FOR STUDIES OF POLYNUCLEOTIDE STRUCTURE AND REACTIONS [J].
BRABEC, V ;
DRYHURST, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1978, 89 (01) :161-173
[3]  
BRABEC V, 1980, J BIOELECTROCHEM BIO, V7, P793
[4]   ON THE ADSORPTION AND ELECTROCHEMICAL OXIDATION OF DNA AT GLASSY-CARBON ELECTRODES [J].
BRETT, CMA ;
BRETT, AMO ;
SERRANO, SHP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 366 (1-2) :225-231
[5]   ELECTROCHEMICAL-BEHAVIOR OF BIOLOGICAL MACROMOLECULES [J].
PALECEK, E .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1986, 15 (02) :275-295
[7]   BIOPOLYMER-MODIFIED ELECTRODES IN THE VOLTAMMETRIC DETERMINATION OF NUCLEIC-ACIDS AND PROTEINS AT THE SUBMICROGRAM LEVEL [J].
PALECEK, E ;
JELEN, F ;
TEIJEIRO, C ;
FUCIK, V ;
JOVIN, TM .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :175-186
[8]   From polarography of DNA to microanalysis with nucleic acid-modified electrodes [J].
Palecek, E .
ELECTROANALYSIS, 1996, 8 (01) :7-14
[9]   DIFFERENTIAL-PULSE VOLTAMMETRIC DETERMINATION OF RNA AT THE PICOMOLE LEVEL IN THE PRESENCE OF DNA AND NUCLEIC-ACID [J].
PALECEK, E ;
FOJTA, M .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1566-1571
[10]  
PALECEK E, 1983, TOPICS BIOELECTROCHE, P65