Spectral Domain Optical Coherence Tomography Imaging of Drusen in Nonexudative Age-Related Macular Degeneration

被引:132
作者
Gregori, Giovanni [1 ]
Wang, Fenghua [1 ]
Rosenfeld, Philip J. [1 ]
Yehoshua, Zohar [1 ]
Gregori, Ninel Z. [1 ]
Lujan, Brandon J. [1 ]
Puliafito, Carmen A. [1 ]
Feuer, William J. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Dept Ophthalmol, Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
SEGMENTATION;
D O I
10.1016/j.ophtha.2010.11.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure drusen area and volume in eyes with nonexudative age-related macular degeneration (AMD) using spectral domain optical coherence tomography imaging (SD-OCT). Design: Evaluation of diagnostic technology. Participants: One hundred three eyes from 74 patients with drusen. Methods: Patients with drusen secondary to nonexudative AMD were enrolled in this study. Five separate SD-OCT scans, each consisting of 40 000 uniformly spaced A-scans organized as 200 A-scans in each B-scan and 200 horizontal B-scans, were performed on each eye. Each scan covered a retinal area of 6 X 6 mm centered on the fovea. A novel algorithm was used to quantitatively assess drusen area and volume. Measurements from the entire scans, as well as in regions contained within 3-and 5-mm circles centered on the fovea, were analyzed. Test-retest standard deviations of drusen area and volume measurements were calculated for each eye. Main Outcome Measures: Drusen area and volume. Results: The algorithm created drusen maps that permitted both qualitative and quantitative assessment of drusen area and volume. Both the qualitative appearance and the quantitative measurements of drusen area and volume were highly reproducible over the 5 different datasets. The intraclass correlation coefficient was >0.99 for both area and volume measurements on the entire dataset as well as the 3-and 5-mm circles. The correlation between lesion size and the test-retest standard deviations can be eliminated by performing a square root transformation of the area measurements and a cube root transformation of the volume measurements. These transformed data allowed for the inclusion of all drusen sizes in the calculation of an estimated single pooled test-retest standard deviation, which will be useful for longitudinal studies of drusen natural history. Conclusions: A novel algorithm for the qualitative and quantitative assessment of drusen imaged using SD-OCT was shown to be highly reproducible. The ability to assess drusen volume reliably represents a new quantitative parameter to measure in AMD and may be useful when assessing disease progression, particularly in trials for treatments of nonexudative AMD.
引用
收藏
页码:1373 / 1379
页数:7
相关论文
共 20 条
[1]   Diagnostic and surgical techniques - Use of fundus imaging in quantification of age-related macular change [J].
Bartlett, Hannah ;
Epejesi, Frank .
SURVEY OF OPHTHALMOLOGY, 2007, 52 (06) :655-671
[2]   Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[3]  
Davis MD, 2005, ARCH OPHTHALMOL-CHIC, V123, P1484
[4]  
FLEISS JL, 1986, DESIGN ANAL CLIN EXP, P24
[5]   OPTICAL COHERENCE TOMOGRAPHY-RASTER SCANNING AND MANUAL SEGMENTATION IN DETERMINING DRUSEN VOLUME IN AGE-RELATED MACULAR DEGENERATION [J].
Freeman, Samuel R. ;
Kozak, Igor ;
Cheng, Lingyun ;
Bartsch, Dirk-Uwe ;
Mojana, Francesca ;
Nigam, Nitin ;
Brar, Manpreet ;
Yuson, Ritchie ;
Freeman, William R. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (03) :431-435
[6]   ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS [J].
Giani, Andrea ;
Cigada, Mario ;
Esmaili, Daniel D. ;
Salvetti, Paola ;
Luccarelli, Saverio ;
Marziani, Ermengarda ;
Luiselli, Cristiano ;
Sabella, Pierfilippo ;
Cereda, Matteo ;
Eandi, Chiara ;
Staurenghi, Giovanni .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (04) :607-616
[7]   Assessment of Artifacts and Reproducibility across Spectral- and Time-Domain Optical Coherence Tomography Devices [J].
Ho, Joseph ;
Sull, Alan C. ;
Vuong, Laurel N. ;
Chen, Yueli ;
Liu, Jonathan ;
Fujimoto, James G. ;
Schuman, Joel S. ;
Duker, Jay S. .
OPHTHALMOLOGY, 2009, 116 (10) :1960-1970
[8]   Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography [J].
Jiao, SL ;
Knighton, R ;
Huang, XR ;
Gregori, G ;
Puliafito, CA .
OPTICS EXPRESS, 2005, 13 (02) :444-452
[9]   Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography [J].
Keane, P. A. ;
Mand, P. S. ;
Liakopoulos, S. ;
Walsh, A. C. ;
Sadda, S. R. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (11) :1461-1467
[10]   Drusen Ultrastructure Imaging with Spectral Domain Optical Coherence Tomography in Age-related Macular Degeneration [J].
Khanifar, Aziz A. ;
Koreishi, Anjum F. ;
Izatt, Joseph A. ;
Toth, Cynthia A. .
OPHTHALMOLOGY, 2008, 115 (11) :1883-1890