An efficient analytical method for determination of S-phenylmercapturic acid in urine by HPLC fluorimetric detector to assessing benzene exposure

被引:8
作者
Rocha Mendes, Michele P. [1 ]
Silveira, Josianne Nicacio [1 ]
Andre, Leiliane Coelho [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Clin & Toxicol Anal, Fac Pharm, Belo Horizonte, MG, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1063卷
关键词
Analytical validation; Benzene; S-phenylmercapturic acid; PERFORMANCE LIQUID-CHROMATOGRAPHY; ENVIRONMENTAL EXPOSURES; METABOLISM;
D O I
10.1016/j.jchromb.2017.07.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benzene is an important occupational and environmental contaminant, naturally present in petroleum and as by-product in the steel industry. Toxicological studies showed pronounced myelotoxic action, causing leukemic and others blood cells disorders. Assessing of benzene exposure, is performed by biomarkers as trans, trans-muconic acid (AttM) and S-phenylmercapturic acid (S-PMA) in urine. Due to specificity of S-PMA, this biomarker has been proposed to asses lower levels of benzene in air. The aim of this study was to validate an analytical method for the quantification of S-PMA by High-Performance Liquid Chromatography with fluorometric detector. The development of an analytical method of S-PMA in urine was carried out by solid phase extraction (SPE) using C-18 phase. The eluated were submitted to water bath at 75 degrees C and nitrogen to analyte concentration, followed by alkaline hydrolysis and derivatization with monobromobimane. The chromatography conditions were reverse phase C-18 column (240 mm, 4 mm and 5 pm) at 35 degrees C; acetonitrile and 0.5% acetic acid (50:50) as mobile phase with a flow of 0.8 mL/min. The limits of detection and quantification were 0.22 mu g/L and 0.68 mu g/L, respectively. The linearity was verified by simple linear regression, and the method exhibited good linearity in the range of 10-100 mu g/L. There was no matrix effect for S-PMA using concentrations of 40, 60, 80 and 100 mu g/L. The infra- and interassay precision showed coefficient of variation of less than 10% and the recovery ranged from 83.4 to 102.8% with an average of 94.4%. The stability of S-P1VIA in urine stored at 20 degrees C was of seven weeks. The conclusion is that this method presents satisfactory results per their figures of merit. This proposed method for determining urinary S-PMA showed adequate sensitivity for assessment of occupational and environmental exposure to benzene using S-PMA as biomarker of exposure.
引用
收藏
页码:136 / 140
页数:5
相关论文
共 28 条
  • [1] A.C.G.I.H, 2016, AM C GOV IND HYG ACG
  • [2] The use of biomonitoring data in exposure and human health risk assessment: benzene case study
    Arnold, Scott M.
    Angerer, Juergen
    Boogaard, Peter J.
    Hughes, Michael F.
    O'Lone, Raegan B.
    Robison, Steven H.
    Schnatter, A. Robert
    [J]. CRITICAL REVIEWS IN TOXICOLOGY, 2013, 43 (02) : 119 - 153
  • [3] Validation of an HPLC-MS-MS Method for the Determination of Urinary S-Benzylmercapturic Acid and S-Phenylmercapturic Acid
    B'Hymer, C.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (07) : 547 - 553
  • [4] Bi-Hua L. V., 2014, OCCUP ENV MED, V56
  • [5] Determination of monobromobimane derivatives of phenylmercapturic and benzylmercapturic acids in urine by high-performance liquid chromatography and fluorimetry
    Buratti, M
    Brambilla, G
    Fustinoni, S
    Pellegrino, O
    Pulviremti, S
    Colombi, A
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02): : 305 - 313
  • [6] SENSITIVE DETERMINATION OF THE BENZENE METABOLITE S-PHENYLMERCAPTURIC ACID IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    EINIG, T
    DEHNEN, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) : 371 - 375
  • [7] EURACHEM, 2014, FITN PURP AN METH LA
  • [8] Method development for the simultaneous analysis of trans,trans-muconic acid, 1,2-dihydroxybenzene, S-phenylmercapturic acid and S-benzylmercapturic acid in human urine by liquid chromatography/tandem mass spectrometry
    Fan, Ruifang
    Wang, Dongli
    She, Jianwen
    [J]. ANALYTICAL METHODS, 2015, 7 (02) : 573 - 580
  • [9] Environmental and lifestyle factors affect benzene uptake biomonitoring of residents near a petrochemical plant
    Fustinoni, Silvia
    Campo, Laura
    Satta, Giannina
    Campagna, Marcello
    Ibba, Antonio
    Tocco, Maria Giuseppina
    Atzeri, Sergio
    Avataneo, Giuseppe
    Flore, Costantino
    Meloni, Michele
    Bertazzi, Pier Alberto
    Cocco, Pierluigi
    [J]. ENVIRONMENT INTERNATIONAL, 2012, 39 (01) : 2 - 7
  • [10] Methodological issues in the biological monitoring of urinary benzene and S-phenylmercapturic acid at low exposure levels
    Fustinoni, Silvia
    Campo, Laura
    Mercadante, Rosa
    Manini, Paola