Statistical Analysis for Quality Adjustment of the Analytical Curve for Determination of Pesticide Multiresidue in Pineapple Samples

被引:24
作者
Alexandre Barbosa, Pablo Gordiano [1 ]
Custodio Martins, Fatima Itana Chaves [1 ]
Lima, Lucelia Katia [2 ]
Liberato Milhome, Maria Aparecida [3 ]
Cavalcante, Rivelino Martins [4 ]
do Nascimento, Ronaldo Ferreira [1 ]
机构
[1] Univ Fed Ceara, Dept Analyt Chem & Phys Chem, R Humberto Monte S-N,Campus Pici,BL 340, BR-60455760 Fortaleza, Ceara, Brazil
[2] Ind Technol Ctr Ceara Fdn NUTEC, Rua Romulo Proenca S-N,Campus Pici, BR-60455760 Fortaleza, Ceara, Brazil
[3] Fed Inst Educ Sci & Technol Ceara IFCE, Rodovia Iguatu Varzea Alegre, BR-60455760 Fortaleza, Ceara, Brazil
[4] Univ Fed Ceara, Inst Marine Sci, Lab Assessment Organ Contaminants LACOr, BR-60455760 Fortaleza, Ceara, Brazil
关键词
Pesticides multiresidues; Pineapple; Heteroscedasticity; weighted least square regression; LINEAR-REGRESSION; METHOD VALIDATION; RESIDUE ANALYSIS; QUECHERS METHOD; CALIBRATION; QUANTIFICATION; GUAVA;
D O I
10.1007/s12161-017-1017-9
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
This work describes the development of an analytical methodology based on the modified QuEChERS method and GC/MS detection involving the analysis of 38 pesticides in pineapple from a local market in Fortaleza-Brazil. Matrix-standard calibration and heteroscedasticity have been studied by a weighted least squares linear regression model application. The analytical curves for most of the analytes (except cyproconazole and pyraclostrobin) presented heteroscedasticity by weighted least square regression (WLS). The weighted correlation coefficient values were in the range of 0.9690 to 0.9987 (linear range of 0.03 to 0.50 mg kg(-1)). The calibration curves obtained by applying regression by ordinary least squares (OLS) showed relative errors of approximately 32.3% for fenpropathrin, 23.1% for buprofezin, 17.4% for methyl parathion, and 13.9% for ametryn. Analysis of commercial pineapple samples revealed the presence of methyl parathion, buprofezin, ametryn, and fenpropathrin at 0.023 +/- 0.0037, 0.013 +/- 0.0047, 0.043 +/- 0.0156, and 0.031 +/- 0.0049 mg kg(-1), respectively.
引用
收藏
页码:466 / 478
页数:13
相关论文
共 39 条
[1]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[2]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[3]  
Anastassiades M., 2007, PESTICIDE CHEM CROP
[4]  
[Anonymous], 2014, SANCO125712013
[5]  
[Anonymous], B ENV CONTAM TOXICOL
[6]  
[Anonymous], MON AGR
[7]  
[Anonymous], STAT ANAL CHEM
[8]  
[Anonymous], EUR UN PEST RES MRLS
[9]  
[Anonymous], SIST AGR FIT AGROFIT
[10]  
[Anonymous], ALIMENTOS NUTR ARARA