The Stability and Survival Rate of Dental Implants After Preparation of the Site by Piezosurgery vs Conventional Drilling: A Systematic Review and Meta-Analysis

被引:12
作者
Li, Xiaoni [1 ]
Lin, Xijiang [1 ]
Guo, Jilai [1 ]
Wang, Yaozhong [1 ]
机构
[1] Qingdao Stomatol Hosp, Dept Oral & Maxillofacial Surg, 17 Dexian Rd, Qingdao 266000, Shandong, Peoples R China
关键词
piezosurgery; site preparation; stability; survival rate; EX-VIVO; HEAT-PRODUCTION; BONE; TEMPERATURE; OSTEOTOMY; SURGERY; TISSUE;
D O I
10.11607/jomi.5913
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to assess the stability and survival rate of dental implants inserted with different site preparation techniques-piezoelectric inserts versus traditional rotary instruments. Materials and Methods: Correlative research was located by searching articles in PubMed, EMBASE, and the Cochrane Library. This was accomplished independently by two different reviewers and supplemented by a manual search. Only prospective studies evaluating piezoelectric vs conventional implant site preparation in dental implantation were included in this review. A meta-analysis was performed on the stability and survival rate of implants. Results: One thousand fifty-five articles were identified following the search strategy, of which five studies were finally included in this meta-analysis. With regard to the survival rate of implants, there was no statistically significant difference between piezoelectric and conventional implant site preparation (RR = 0.98, 95% CI: 0.94, 1.03; I-2 = 0%, P = .86). On the other side, the piezoelectric group had better stability in the eighth week (MD = 4.24, 95% CI: 1.36, 7.12; I-2 = 0%, P = .80) and 12th week (MD = 3.33, 95% CI: 0.59, 6.08; I-2 = 0%, P = .87) compared with the conventional group. Conclusion: Within the limitations of this study, it suggests that the survival rate of implants may not be influenced by the site preparation techniques (piezoelectric vs conventional), but the piezoelectric group may achieve better stability than the conventional group.
引用
收藏
页码:E51 / E56
页数:6
相关论文
共 26 条
[1]   Analysis of temperature in conventional and ultrasonically-assisted drilling of cortical bone with infrared thermography [J].
Alam, K. ;
Silberschmidt, Vadim V. .
TECHNOLOGY AND HEALTH CARE, 2014, 22 (02) :243-252
[2]   Investigation of the effect of movement and irrigation systems on temperature in the conventional drilling of cortical bone [J].
Alexandre Gehrke, Sergio ;
Neto, Henrique Loffredo ;
Mardegan, Fabio E. C. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (08) :953-957
[3]   Piezoelectric vs. conventional implant site preparation: ex vivo implant primary stability [J].
Baker, Justin A. ;
Vora, Shweta ;
Bairam, Latifa ;
Kim, Hyeong-il ;
Davis, Elaine L. ;
Andreana, Sebastiano .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) :433-437
[4]   Piezoelectric vs. conventional drilling in implant site preparation: pilot controlled randomized clinical trial with crossover design [J].
Canullo, Luigi ;
Penarrocha, David ;
Penarrocha, Miguel ;
Rocio, Alonso-Gonzalez ;
Penarrocha-Diago, Maria .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (12) :1336-1343
[5]   Autogenous bone chips:: influence of a new piezoelectric device (Piezosurgery®) on chip morphology, cell viability and differentiation [J].
Chiriac, G ;
Herten, M ;
Schwarz, F ;
Rothamel, D ;
Becker, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :994-999
[6]   Characterisation of bone following ultrasonic cutting [J].
Claire, Sunil ;
Lea, Simon C. ;
Walmsley, A. Damien .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) :905-912
[7]   Clinical analysis of the stability of dental implants after preparation of the site by conventional drilling or piezosurgery [J].
da Silva Neto, Ulisses Tavares ;
Joly, Julio Cesar ;
Alexandre Gehrke, Sergio .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (02) :149-153
[8]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[9]  
Di Alberti L, 2010, QUINTESSENCE INT, V41, P639
[10]   Primary Stability Comparison Using Piezoelectric or Conventional Implant Site Preparation Systems in Cancellous Bone: A Pilot Study [J].
Gandhi, Shweta A. ;
Baker, Justin A. ;
Bairam, Latifa ;
Kim, Hyeong-Il ;
Davis, Elaine L. ;
Andreana, Sebastiano .
IMPLANT DENTISTRY, 2014, 23 (01) :79-84