Pre-analytical factors affect the accurate measurement of testosterone concentrations in plasma and serum of goats

被引:2
作者
Gholib, G. [1 ]
Wahyuni, S. [1 ]
Abdilla, A. [1 ]
Nugraha, T. P. [2 ]
机构
[1] Univ Syiah Kuala, Fac Vet Med, Banda Aceh 23111, Aceh, Indonesia
[2] Indonesian Inst Sci LIPI, Biol Res Ctr, Lab Reprod Div Zool, Cibinong 16914, West Java, Indonesia
来源
POLISH JOURNAL OF VETERINARY SCIENCES | 2021年 / 24卷 / 03期
关键词
centrifugation time; collection time; ELISA; goats; sample storage; LINKED-IMMUNOSORBENT-ASSAY; ADRENOCORTICOTROPIC HORMONE; BLOOD-SAMPLES; DIURNAL-VARIATION; ROOM-TEMPERATURE; WHOLE-BLOOD; PROGESTERONE; HEMOLYSIS; STORAGE; STABILITY;
D O I
10.24425/pjvs.2021.138726
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Several pre-analytical factors may influence the accurate measurements of testosterone (T) and therefore, these factors must be a significant concern. This study aimed to examine the effects of 1) time of sample collection, 2) delay to centrifugation, 3) sample matrix types, and 4) device and duration of sample storage on the T concentrations. Blood samples were collected from 34 bucks of Kacang goats. For testing the effect of collection time, 12 pairs of morning and afternoon samples were collected. For testing the effect of delayed centrifugation, 24 samples were subjected to treatments: (i) centrifuged < 1 hour after collection (control group), (ii) centrifuged 6, 12, and 24 hours after collection (test groups). For testing the different sample matrix types, 10 samples were processed as serum and plasma. For testing the effect of sample storage device and duration, 60 samples were subjected to treatments: i) frozen at-20OC (control group), ii) stored in a cooler box, a styrofoam box, and a thermos-flask for two, four, and six days (test groups). T concentrations were measured using a validated testosterone ELISA kit. Concentrations of plasma testosterone (pT) from morning samples were significantly higher compared to afternoon samples (p<0.05). Delayed centrifugation for up to 24 h decreased significantly on pT concentrations (p<0.05). The concentrations of T from serum and plasma did not differ and showed a strong correlation (r=0.981). Storage device and duration affected the T concentrations compared to frozen samples (p<0.05) which T concentrations were stable for up to 4 days in a styrofoam box and a thermos-flask and up to 6 days in a cooler box. In conclusion, the measurement accuracy and stability of T concentrations in goats are affected by collection time, delay to centrifugation, and device and duration of storage.
引用
收藏
页码:355 / 363
页数:9
相关论文
共 38 条
  • [31] Stability of 12 T-helper cell-associated cytokines in human serum under different pre-analytical conditions
    Stervbo, Ulrik
    Bajda, Sharon
    Wehler, Patrizia
    Rohn, Benjamin J.
    Streichhahn, Melanie
    Temizsoy, Sehriban
    Kohut, Eva
    Roch, Toralf
    Viebahn, Richard
    Westhoff, Timm H.
    Babel, Nina
    CYTOKINE, 2020, 129
  • [32] Performance evaluation and characterization of pre-analytical effects by sample types and storage conditions on tumor marker measurement by the point-of-care test platform IchromaTM II
    Lee, Sojin
    Jang, Jaehyeok
    Jang, Hanmil
    Kang, Hyein
    Rim, John Hoon
    Lim, Jong-Baeck
    CLINICA CHIMICA ACTA, 2024, 563
  • [33] Development of a total serum testosterone, androstenedione, 17-hydroxyprogesterone, 11β-hydroxyandrostenedione and 11-ketotestosterone LC-MS/MS assay and its application to evaluate pre-analytical sample stability
    Hawley, James M.
    Adaway, Joanne E.
    Owen, Laura J.
    Keevil, Brian G.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (05) : 741 - 752
  • [34] Determination of methionine-enkephalin and leucine-enkephalin by LC-MS It in human plasma: Study of pre-analytical stability
    Ozalp, Aliye
    Barroso, Begona
    Meijer, John
    van den Beld, Cas
    ANALYTICAL BIOCHEMISTRY, 2018, 559 : 24 - 29
  • [35] Multicentric study of the effect of pre-analytical variables in the quality of plasma samples stored in biobanks using different complementary proteomic methods
    Mateos, Jesus
    Carneiro, Isabel
    Corrales, Fernando
    Elortza, Felix
    Paradela, Alberto
    Sanchez del Pino, Manuel
    Iloro, Ibon
    Marcilla, Miguel
    Isabel Mora, Maria
    Valero, Luz
    Ciordia, Sergio
    Fernandez, Veronica
    Antonia Fortuno, Maria
    Garcia-Sanchez, Isabel
    Martinez, Rosario
    Angeles Munoz, Maria
    Rodriguez, Clara
    Domenech, Nieves
    JOURNAL OF PROTEOMICS, 2017, 150 : 109 - 120
  • [36] Pre-analytical factors that influence the interpretation of prothrombin time in the clinical laboratory: One year experience in a super speciality hospital in India
    Goswami, Binita
    Tayal, Devika
    Chawla, Ranjna
    Mallika, V.
    CLINICA CHIMICA ACTA, 2009, 410 (1-2) : 93 - 94
  • [37] How pre-analytical conditions impact glucose measurement and (gestational) diabetes diagnosis: A real-world stability study and a call for harmonization
    Nevraumont, Arnaud
    Deltombe, Matthieu
    Bayart, Jean-Louis
    CLINICA CHIMICA ACTA, 2024, 562
  • [38] Pre-analytical stability of haematinics, lactate dehydrogenase and phosphate in whole blood at room temperature up to 24 h, and refrigerated serum stability of lactate dehydrogenase, folate and vitamin B12 up to 72 h using the CRESS checklist
    Williams, Robert
    Jankute, Monika
    Ifrahim, Rizwan
    Cordle, Jane
    Hepburn, Sophie
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, : 734 - 746