Novel surface plasmon resonance sensor chip functionalized with organic silica compounds for antibody attachment

被引:35
作者
Sasaki, S
Nagata, R
Hock, B
Karube, I
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
[2] Dai Nippon Printing Co Ltd, Cent Res Inst, Kashiwa, Chiba 277, Japan
[3] Tech Univ Munchen Weihenstephan, Dept Bot, D-85350 Freising, Germany
关键词
surface plasmon resonance; antibody immobilization; atrazine; human serum albumin;
D O I
10.1016/S0003-2670(98)00200-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method was developed for the fabrication of a surface plasmon resonance (SPR) sensor chip. A glass chip was covered with a gold layer which was then functionalized with gamma-aminopropylethoxysilane. Biomolecules could then be immobilized on the surface of the sensor using standard techniques. The sensor chip was found to be useful for highly sensitive SPR measurements using even smaller amounts of antibody than usual. The chip was found to be useful for the immobilization of anti-human serum albumin (anti-HSA) and anti-atrazine antibody, and was used for the SPR measurement of HSA and enzyme-labeled atrazine. The chip showed higher responses at both 10 and 100 mg l(-1) HSA than a commercially available model, The relative standard deviation (RSD) of the responses was 7% for both concentrations of HSA (n = 8). A monoclonal antibody for atrazine was immobilized on the chip and 0.05 mu g l(-1) atrazine was measured with a RSD of 7% (n = 5). Atrazine was determined after addition to river water; 0.05 mu g l(-1) atrazine was detected with a very similar response as a standard atrazine solution of the same concentration. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 18 条
  • [1] THE DETECTION AND IDENTIFICATION OF METAL AND ORGANIC POLLUTANTS IN POTABLE WATER USING ENZYME ASSAYS SUITABLE FOR SENSOR DEVELOPMENT
    COWELL, DC
    DOWMAN, AA
    ASHCROFT, T
    CAFFOOR, I
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) : 509 - 516
  • [2] A PIEZOELECTRIC IMMUNOBIOSENSOR FOR ATRAZINE IN DRINKING-WATER
    GUILBAULT, GG
    HOCK, B
    SCHMID, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (06) : 411 - 419
  • [3] ENHANCEMENT OF IMMUNOASSAY SENSITIVITY BY MOLECULAR MODIFICATION OF COMPETITORS
    JOCKERS, R
    BIER, FF
    SCHMID, RD
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 163 (02) : 161 - 167
  • [4] KINETIC-ANALYSIS OF MONOCLONAL ANTIBODY-ANTIGEN INTERACTIONS WITH A NEW BIOSENSOR BASED ANALYTICAL SYSTEM
    KARLSSON, R
    MICHAELSSON, A
    MATTSSON, L
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 145 (1-2) : 229 - 240
  • [5] DETECTION OF PESTICIDE IN DRINKING-WATER USING REAL-TIME BIOSPECIFIC INTERACTION ANALYSIS (BIA)
    MINUNNI, M
    MASCINI, M
    [J]. ANALYTICAL LETTERS, 1993, 26 (07) : 1441 - 1460
  • [6] Reflectometric interference spectroscopy for the determination of atrazine in natural water samples
    Mouvet, C
    Amalric, L
    Broussard, S
    Lang, G
    Brecht, A
    Gauglitz, G
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (06) : 1846 - 1851
  • [7] NAKAMURA R, UNPUB ANAL CHEM
  • [8] LIPOSOME AND PROTEOLIPOSOME FUSION ONTO SOLID SUBSTRATES, STUDIED USING ATOMIC-FORCE MICROSCOPY, QUARTZ-CRYSTAL MICROBALANCE AND SURFACE-PLASMON RESONANCE - BIOLOGICAL-ACTIVITIES OF INCORPORATED COMPONENTS
    OHLSSON, PA
    TJARNHAGE, T
    HERBAI, E
    LOFAS, S
    PUU, G
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1995, 38 (01): : 137 - 148
  • [9] AN AMPEROMETRIC ALGAL BIOSENSOR FOR HERBICIDE DETECTION EMPLOYING A CARBON CATHODE OXYGEN-ELECTRODE
    PANDARD, P
    RAWSON, DM
    [J]. ENVIRONMENTAL TOXICOLOGY AND WATER QUALITY, 1993, 8 (03): : 323 - 333
  • [10] Pandard Pascal, 1992, Revue des Sciences de l'Eau, V5, P445