Influence of Cell Cycle Phase on Apparent Diffusion Coefficient in Synchronized Cells Detected Using Temporal Diffusion Spectroscopy

被引:33
作者
Xu, Junzhong [1 ,2 ]
Xie, Jingping [1 ,2 ]
Jourquin, Jerome [3 ]
Colvin, Daniel C. [1 ,2 ]
Does, Mark D. [1 ,2 ,4 ,5 ]
Quaranta, Vito [3 ]
Gore, John C. [1 ,2 ,4 ,6 ,7 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Canc Biol, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[7] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
关键词
diffusion; oscillating gradient; MRI; intracellular structure; cell phase; cell size; surface-to-volume ratio; ANISOTROPIC WATER DIFFUSION; TIME-DEPENDENT DIFFUSION; INTRACELLULAR WATER; VOLUME; NMR; SYSTEM; HL-60; MR;
D O I
10.1002/mrm.22704
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The relationship between the apparent diffusion coefficient of tissue water measured by MR methods and the physiological status of cells is of particular relevance for better understanding and interpretation of diffusion-weighted MRI. In addition, there is considerable interest in developing diffusion-dependent imaging methods capable of providing novel information on tissue microstructure, including intracellular changes. To this end, both the conventional pulsed gradient spin-echo methods and the oscillating gradient spin-echo method, which probes diffusion over very short distance (<<cell size) and time scales, were used to measure apparent diffusion coefficient of synchronized packed HL-60 cells at 7 T. The results show that the pulsed gradient spin-echo method with relatively long diffusion times does not detect changes in apparent diffusion coefficient when structural variations arise during cell division. On the contrary, the oscillating gradient spin-echo method can detect and quantify major changes in intracellular organization that occur during mitosis by appropriate choice of gradient frequency. Cell structural parameters, including cell size, intracellular diffusion coefficient, and surface-to-volume ratio were also obtained by fitting the oscillating gradient spin-echo data to simple analytical models. These oscillating gradient spin-echo features may be used in diffusion-weighted MRI to create parametric maps that may be useful for detecting cancer or changes caused by treatment. Magn Reson Med 65:920-926, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:920 / 926
页数:7
相关论文
共 25 条
  • [11] TIME-DEPENDENT DIFFUSION-COEFFICIENT OF FLUIDS IN POROUS-MEDIA AS A PROBE OF SURFACE-TO-VOLUME RATIO
    LATOUR, LL
    MITRA, PP
    KLEINBERG, RL
    SOTAK, CH
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 101 (03) : 342 - 346
  • [12] TIME-DEPENDENT DIFFUSION OF WATER IN A BIOLOGICAL MODEL SYSTEM
    LATOUR, LL
    SVOBODA, K
    MITRA, PP
    SOTAK, CH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (04) : 1229 - 1233
  • [13] The 'wet mind': water and functional neuroimaging
    Le Bihan, Denis
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07) : R57 - R90
  • [14] Nuclear phospholipase C-β1b activation during G2/M and late G1 phase in nocodazole-synchronized HL-60 cells
    Lukinovic-Skudar, V
    Donlagic, L
    Banfíc, H
    Visnjic, D
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2005, 1733 (2-3): : 148 - 156
  • [15] SYNCHRONIZATION OF THE HUMAN PROMYELOCYTIC CELL-LINE HL-60 BY THYMIDINE
    MORTENSEN, BT
    HARTMANN, NR
    CHRISTENSEN, IJ
    LARSEN, JK
    KRISTENSEN, T
    WIESLANDER, SB
    NISSEN, NI
    [J]. CELL AND TISSUE KINETICS, 1986, 19 (03): : 351 - 364
  • [16] A SIMPLE METHOD FOR OBTAINING CROSS-TERM-FREE IMAGES FOR DIFFUSION ANISOTROPY STUDIES IN NMR MICROIMAGING
    NEEMAN, M
    FREYER, JP
    SILLERUD, LO
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (01) : 138 - 143
  • [17] Temporal diffusion spectroscopy: Theory and implementation in restricted systems using oscillating gradients
    Parsons, EC
    Does, MD
    Gore, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) : 75 - 84
  • [18] Intracellular volume and apparent diffusion constants of perfused cancer cell cultures, as measured by NMR
    Pilatus, U
    Shim, H
    Artemov, D
    Davis, D
    vanZijl, PCM
    Glickson, JD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) : 825 - 832
  • [19] Measurements of restricted diffusion using an oscillating gradient spin-echo sequence
    Schachter, M
    Does, MD
    Anderson, AW
    Gore, JC
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2000, 147 (02) : 232 - 237
  • [20] INTRACELLULAR DIFFUSION OF WATER
    TANNER, JE
    [J]. ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1983, 224 (02) : 416 - 428