Influence of Cell Cycle Phase on Apparent Diffusion Coefficient in Synchronized Cells Detected Using Temporal Diffusion Spectroscopy

被引:33
作者
Xu, Junzhong [1 ,2 ]
Xie, Jingping [1 ,2 ]
Jourquin, Jerome [3 ]
Colvin, Daniel C. [1 ,2 ]
Does, Mark D. [1 ,2 ,4 ,5 ]
Quaranta, Vito [3 ]
Gore, John C. [1 ,2 ,4 ,6 ,7 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Canc Biol, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
[5] Vanderbilt Univ, Dept Elect Engn & Comp Sci, Nashville, TN 37232 USA
[6] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[7] Vanderbilt Univ, Dept Mol Physiol & Biophys, Nashville, TN 37232 USA
关键词
diffusion; oscillating gradient; MRI; intracellular structure; cell phase; cell size; surface-to-volume ratio; ANISOTROPIC WATER DIFFUSION; TIME-DEPENDENT DIFFUSION; INTRACELLULAR WATER; VOLUME; NMR; SYSTEM; HL-60; MR;
D O I
10.1002/mrm.22704
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The relationship between the apparent diffusion coefficient of tissue water measured by MR methods and the physiological status of cells is of particular relevance for better understanding and interpretation of diffusion-weighted MRI. In addition, there is considerable interest in developing diffusion-dependent imaging methods capable of providing novel information on tissue microstructure, including intracellular changes. To this end, both the conventional pulsed gradient spin-echo methods and the oscillating gradient spin-echo method, which probes diffusion over very short distance (<<cell size) and time scales, were used to measure apparent diffusion coefficient of synchronized packed HL-60 cells at 7 T. The results show that the pulsed gradient spin-echo method with relatively long diffusion times does not detect changes in apparent diffusion coefficient when structural variations arise during cell division. On the contrary, the oscillating gradient spin-echo method can detect and quantify major changes in intracellular organization that occur during mitosis by appropriate choice of gradient frequency. Cell structural parameters, including cell size, intracellular diffusion coefficient, and surface-to-volume ratio were also obtained by fitting the oscillating gradient spin-echo data to simple analytical models. These oscillating gradient spin-echo features may be used in diffusion-weighted MRI to create parametric maps that may be useful for detecting cancer or changes caused by treatment. Magn Reson Med 65:920-926, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:920 / 926
页数:7
相关论文
共 25 条
  • [1] Effects of cell volume fraction changes on apparent diffusion in human cells
    Anderson, AW
    Xie, J
    Pizzonia, J
    Bronen, RA
    Spencer, DD
    Gore, JC
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 689 - 695
  • [2] NUCLEAR MAGNETIC-RESONANCE PATTERNS OF INTRACELLULAR WATER AS A FUNCTION OF HELA-CELL CYCLE
    BEALL, PT
    HAZLEWOOD, CF
    RAO, PN
    [J]. SCIENCE, 1976, 192 (4242) : 904 - 907
  • [3] DETERMINANTS OF ANISOTROPIC WATER DIFFUSION IN NERVES
    BEAULIEU, C
    ALLEN, PS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) : 394 - 400
  • [4] The basis of anisotropic water diffusion in the nervous system - a technical review
    Beaulieu, C
    [J]. NMR IN BIOMEDICINE, 2002, 15 (7-8) : 435 - 455
  • [5] NMR-STUDIES OF INTRACELLULAR WATER AT 300 MHZ - T2-SPECIFIC RELAXATION MECHANISMS IN SYNCHRONIZED OR EGF-STIMULATED CELLS
    CALLAHAN, DE
    DEAMOND, SF
    CREASEY, DC
    TRAPANE, TL
    BRUCE, SA
    TSO, POP
    KAN, LS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) : 68 - 80
  • [6] New insights into tumor microstructure using temporal diffusion spectroscopy
    Colvin, Daniel C.
    Yankeelov, Thomas E.
    Does, Mark D.
    Yue, Zoe
    Quarles, Chad
    Gore, John C.
    [J]. CANCER RESEARCH, 2008, 68 (14) : 5941 - 5947
  • [7] COLVIN DC, 2010, P 18 ANN M ISMRM STO, P297
  • [8] COLVIN DC, 2006, P 14 ANN M ISMRM SEA, P1633
  • [9] Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
    Does, MD
    Parsons, EC
    Gore, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 206 - 215
  • [10] Uncovering of intracellular water in cultured cells
    Galons, JP
    Lope-Piedrafita, S
    Divijak, JL
    Corum, C
    Gillies, RJ
    Trouard, TP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 79 - 86