Determination of indoor air quality of a phytosanitary plant

被引:10
作者
Sanjuan-Herraez, Daniel [1 ]
Rodriguez-Carrasco, Yelko [1 ]
Juan-Peiro, Luis [1 ]
Pastor, Agustin [1 ]
de la Guardia, Miguel [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
关键词
Phytosanitary plant; Passive samplers; Air quality; Pesticides; Volatile organic compounds; SEMIPERMEABLE-MEMBRANE DEVICES; MICROWAVE-ASSISTED EXTRACTION; VOLATILE ORGANIC-COMPOUNDS; AMBIENT AIR; PESTICIDES; RESIDUES; SPMDS;
D O I
10.1016/j.aca.2011.03.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new methodology has been developed to determine volatile organic compounds (VOCs) and pesticides in ambient air using membrane based devices as passive samplers. Pesticides were determined by gas chromatography with mass spectrometry detection (GC-MS) after their microwave-assisted extraction (MAE) from the passive sampler and the required clean-up. On the other hand, VOCs were also caught with the same samplers and directly determined by head space (HS) coupled to GC-MS. The use of samplers filled with florisil and activated carbon allows us to catch with a simple device both, VOCs and pesticides, with a high vapor pressure. Results obtained in the deployment of samplers in different sites of a phytosanitary plant evidenced the presence of high quantities of chlorpyriphos at thousand ng m(3) and also metalaxyl, oxyfluorphen and lindane at ng m(3) together with carbon disulfide, 2,2,4-trimethylpentane, ethylbenzene and xylene. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 18 条
  • [11] Advances in passive sampling in environmental studies
    Kot-Wasik, Agata
    Zabiegala, Bozena
    Urbanowicz, Magdalena
    Dominiak, Ewa
    Wasik, Andrzej
    Namiesnik, Jacek
    [J]. ANALYTICA CHIMICA ACTA, 2007, 602 (02) : 141 - 163
  • [12] A passive sampling-based analytical strategy for the determination of volatile organic compounds in the air of working areas
    Ly-Verdu, Saray
    Esteve-Turrillas, Francesc A.
    Pastor, Agustin
    de la Guardia, Miguel
    [J]. ANALYTICA CHIMICA ACTA, 2010, 677 (02) : 131 - 139
  • [13] Determination of volatile organic compounds in contaminated air using semipermeable membrane devices
    Ly-Verdu, Saray
    Esteve-Turrillas, Francesc A.
    Pastor, Agustin
    de la Guardia, Miguel
    [J]. TALANTA, 2010, 80 (05) : 2041 - 2048
  • [14] PASTOR A, Patent No. 2009009126
  • [15] United States Environmental Protection Agency, INTR IND AIR QUAL
  • [16] Microwave-assisted extraction of polybrominated diphenyl ethers and polychlorinated naphthalenes concentrated on semipermeable membrane devices
    Yusá, V
    Pastor, A
    de la Guardia, M
    [J]. ANALYTICA CHIMICA ACTA, 2006, 565 (01) : 103 - 111
  • [17] Microwave-assisted extraction of OCPs, PCBs and PAHs concentrated by semi-permeable membrane devices (SPMDs)
    Yusà, V
    Pastor, A
    de la Guardia, M
    [J]. ANALYTICA CHIMICA ACTA, 2005, 540 (02) : 355 - 366
  • [18] Sampling and analysis of pesticides in ambient air
    Yusa, V.
    Coscolla, C.
    Mellouki, W.
    Pastor, A.
    de la Guardia, M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) : 2972 - 2983