Targeted Transendocardial Therapeutic Delivery Guided by MRI-X-ray Image Fusion

被引:14
作者
Tomkowiak, Michael T. [1 ]
Klein, Andrew J. [2 ]
Vigen, Karl K. [3 ]
Hacker, Timothy A. [2 ]
Speidel, Michael A. [4 ]
VanLysel, Michael S. [2 ,4 ]
Raval, Amish N. [2 ]
机构
[1] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[2] Univ Wisconsin, Dept Med, Div Cardiovasc Med, Madison, WI USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
registration; myocardial infarction; image-guided therapy; magnetic resonance imaging; x-ray fluoroscopy; MESENCHYMAL STEM-CELLS; RANDOMIZED CONTROLLED-TRIAL; MYOCARDIAL-INFARCTION; DOUBLE-BLIND; TRANSPLANTATION; INJECTION; FLUOROSCOPY; ANGINA; SWINE;
D O I
10.1002/ccd.22901
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To validate a multi-modality image fusion approach to guide catheter-based, targeted transendocardial therapeutic delivery in a swine myocardial infarction (MI) model. Background: Biologic agents such as stem cells may curb post MI adverse ventricular remodeling if delivered by a transendocardial catheter directly into the infarct border. 3D visualization of the infarct and other cardiac surfaces is required to perform this task. We propose registering and overlaying magnetic resonance imaging (MRI) roadmaps onto live x-ray fluoroscopy (XRF) to guide targeted transendocardial delivery. Methods: Custom software was used to register and overlay MRI models of the endocardium and infarct on live XRF by aligning common endocardial border features. In a swine MI model, transendocardial injections of co-localizing imaging labels were performed, targeting a 20 mm perimeter around the infarct. Directed targeting error (DTE) was defined as the difference between the predicted injection site-to-infarct distance calculated by the image fusion system, to the actual distance determined by postprocedure in vivo MRI. The mobile image fusion system was designed to be vendor-independent for imaging systems and transendocardial catheters. Results: Transendocardial injections were performed in all animals without complications. Mean DTE was 0.9 +/- 5.0 mm (n = 8 swine). Time to register the images and establish a high quality roadmap was less than 12 min in all animals. Custom imaging tools to display injection sites and distribution were useful adjuncts during targeted injection procedures. Conclusions: Multi-modality image fusion is a feasible and accurate platform technology to guide transendocardial injections precisely to the discrete infarct border. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:468 / 478
页数:11
相关论文
共 19 条
  • [1] Amado LC, 2005, P NATL ACAD SCI USA, V102, P11474, DOI 10.1073/pnas.0504388102
  • [2] Prospective Electrocardiogram-Gated Delayed Enhanced Multidetector Computed Tomography Accurately Quantifies Infarct Size and Reduces Radiation Exposure
    Chang, Hyuk-Jae
    George, Richard T.
    Schuleri, Karl H.
    Evers, Kristine
    Kitagawa, Kakuya
    Lima, Joao A. C.
    Lardo, Albert C.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2009, 2 (04) : 412 - 420
  • [3] X-ray fused with magnetic resonance imaging (XFM) to target endomyocardial injections - Validation in a swine model of myocardial infarction
    de Silva, Ranil
    Gutierrez, Luis F.
    Raval, Amish N.
    McVeigh, Elliot R.
    Ozturk, Cengizhan
    Lederman, Robert J.
    [J]. CIRCULATION, 2006, 114 (22) : 2342 - 2350
  • [4] Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine
    Dick, AJ
    Guttman, MA
    Raman, VK
    Peters, DC
    Pessanha, BSS
    Hill, JM
    Smith, S
    Scott, G
    McVeigh, ER
    Lederman, RJ
    [J]. CIRCULATION, 2003, 108 (23) : 2899 - 2904
  • [5] Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation:: Accuracy and clinical value
    Ector, Joris
    De Buck, Stijn
    Huybrechts, Wim
    Nuyens, Dieter
    Dymarkowski, Steven
    Bogaert, Jan
    Maes, Frederik
    Heidbuchel, Hein
    [J]. HEART RHYTHM, 2008, 5 (07) : 957 - 964
  • [6] OPTIMAL SURFACE RECONSTRUCTION FROM PLANAR CONTOURS
    FUCHS, H
    KEDEM, ZM
    USELTON, SP
    [J]. COMMUNICATIONS OF THE ACM, 1977, 20 (10) : 693 - 702
  • [7] Cone-beam reprojection using projection-matrices
    Galigekere, RR
    Wiesent, K
    Holdsworth, DW
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (10) : 1202 - 1214
  • [8] Distortion correction, calibration, and registration:: Towards an integrated MR and X-ray interventional suite
    Gutiérrez, LF
    Shechter, G
    Lederman, RJ
    McVeigh, ER
    Ozturk, C
    [J]. MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 146 - 156
  • [9] Direct intramyocardial plasmid vascular endothelial growth factor-A165-gene therapy in patients with stable severe angina pectoris -: A randomized double-blind placebo-controlled study:: The Euroinject One trial
    Kastrup, J
    Jorgensen, E
    Rück, A
    Tägil, K
    Glogar, D
    Ruzyllo, W
    Botker, HE
    Dudek, D
    Drvota, V
    Hesse, B
    Thuesen, L
    Blomberg, P
    Gyöngyösi, M
    Sylvén, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 982 - 988
  • [10] The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction.
    Kim, RJ
    Wu, E
    Rafael, A
    Chen, EL
    Parker, MA
    Simonetti, O
    Klocke, FJ
    Bonow, RO
    Judd, RM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) : 1445 - 1453