240-GHz Reflectometer-Based Dielectric Sensor With Integrated Transducers in a 130-nm SiGe BiCMOS Technology

被引:9
作者
Wang, Defu [1 ]
Eissa, Mohamed Hussein [2 ]
Schmalz, Klaus [2 ]
Kaempfe, Thomas [1 ]
Kissinger, Dietmar [3 ]
机构
[1] Fraunhofer IPMS, D-01099 Dresden, Germany
[2] IHP Leibniz Inst Innovat Mikroelekt, D-15236 Frankfurt, Oder, Germany
[3] Ulm Univ, Inst Elect Devices & Circuits, D-89081 Ulm, Germany
关键词
Transducers; Dielectrics; Sensors; Biomedical measurement; Sensitivity; System-on-chip; Semiconductor device measurement; Dielectric sensor; heterodyne; mm-Wave; reflectometer; SiGe; submillimeter-wave; vector network analyzer (VNA); VECTOR NETWORK ANALYZERS; SPECTROSCOPY; CIRCUIT;
D O I
10.1109/TMTT.2020.3038382
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents a reflectometer-based on-chip dielectric sensor with integrated transducers at 240 GHz. The chip simplifies the measurement of a vector network analyzer (VNA) to sense the incident and reflected waves by using two heterodyne mixer-based receivers with a dielectric sensing element. Radio frequency (RF) and local oscillator (LO) submillimeter waves are generated by two frequency multiplier chains, respectively. Two back-to-back identical differential side-coupled directive couplers are proposed to separate the incident and reflected signals and couple them to mixers. Both transmission line and coplanar stripline transducers are proposed and integrated with reflectometer to investigate the sensitivity of dielectric sensors. The latter leads to a larger power variation of the reflectometer by providing more sufficient operating bands for the magnitude and phase slope of S11. The readout of the transducers upon exposure to liquids is performed by the measurement of their reflected signals using two external excitation sources. The experimental dielectric sensing is demonstrated by using binary methanol-ethanol mixture placed on the proposed on-chip dielectric sensor in the assembled printed circuit board. It enables a maximum 8 dB of the power difference between the incident and reflected channels on the measurement of liquid solvents. Both chips occupy an area of 4.03 mm2 and consume 560 mW. Along with a wide operational frequency range from 200 to 240 GHz, this simplified one-port-VNA-based on-chip device makes it feasible for the use of handle product and suitable for the submillimeter-wave dielectric spectroscopy applications.
引用
收藏
页码:1027 / 1035
页数:9
相关论文
共 31 条
[1]   A 100-300-GHz Free-Space Scalar Network Analyzer Using Compact Tx and Rx Modules [J].
Alazemi, Abdullah J. ;
Rebeiz, Gabriel M. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (11) :4021-4029
[2]  
Bon-Hyun Ku, 2017, 2017 IEEE MTT-S International Microwave Symposium (IMS), P980, DOI 10.1109/MWSYM.2017.8058753
[3]  
Chien J.-C., 2013, IEEE MTT-S International Microwave Symposium Digest, P1
[4]   A Packaged 0.01-26-GHz Single-Chip SiGe Reflectometer for Two-Port Vector Network Analyzers [J].
Chung, Hyunchul ;
Ma, Qian ;
Sayginer, Mustafa ;
Rebeiz, Gabriel M. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (05) :1794-1808
[5]   Integrated Systems for Biomedical Applications: Silicon-Based RF/Microwave Dielectric Spectroscopy and Sensing [J].
Entesari, Kamran ;
Helmy, Ahmed A. ;
Moslehi-Bajestan, Masoud .
IEEE MICROWAVE MAGAZINE, 2017, 18 (05) :57-72
[6]   Integrated Broadband Microwave and Microfluidic Sensor Dedicated to Bioengineering [J].
Grenier, Katia ;
Dubuc, David ;
Poleni, Paul-Emile ;
Kumemura, Momoko ;
Toshiyoshi, Hiroshi ;
Fujii, Teruo ;
Fujita, Hiroyuki .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2009, 57 (12) :3246-3253
[7]   Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes [J].
Hayashi, Y ;
Livshits, L ;
Caduff, A ;
Feldman, Y .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (04) :369-374
[8]   A 1-8-GHz Miniaturized Spectroscopy System for Permittivity Detection and Mixture Characterization of Organic Chemicals [J].
Helmy, Ahmed A. ;
Entesari, Kamran .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2012, 60 (12) :4157-4170
[9]   Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications [J].
Hofmann, Maximilian ;
Fischer, Georg ;
Weigel, Robert ;
Kissinger, Dietmar .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) :2195-2204
[10]   Low-Power Miniature K-Band Sensors for Dielectric Characterization of Biomaterials [J].
Jamal, Farabi Ibne ;
Guha, Subhajit ;
Eissa, Mohamed Hussein ;
Borngraeber, Johanes ;
Meliani, Chafik ;
Ng, Herman Jalli ;
Kissinger, Dietmar ;
Wessel, Jan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (03) :1012-1023