Fast FLAIR MRI in childhood white-matter abnormalities

被引:8
作者
Demaerel, P [1 ]
Bosmans, H [1 ]
Caerts, B [1 ]
Herpels, V [1 ]
Vercruysse, J [1 ]
Verslegers, I [1 ]
Wilms, G [1 ]
Baert, AL [1 ]
机构
[1] Univ Hosp, Dept Radiol, B-3000 Louvain, Belgium
关键词
magnetic resonance imaging; white matter diseases; children; pulse sequences;
D O I
10.1007/s002340050598
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared a fast fluid-attenuated inversion recovery (FLAIR) pulse sequence with a dual-echo short tau fast inversion-recovery (DESTTIR) sequence in 20 children with white matter abnormalities. Although the overall image quality of DESTTIR images was better, the lesion-to-background contrast was significantly higher with the fast FLAIR pulse sequence and lesion detection was more accurate.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 12 条
[1]   MAGNETIC-RESONANCE-IMAGING IN PARTIAL EPILEPSY - ADDITIONAL ABNORMALITIES SHOWN WITH THE FLUID ATTENUATED INVERSION-RECOVERY (FLAIR) PULSE SEQUENCE [J].
BERGIN, PS ;
FISH, DR ;
SHORVON, SD ;
OATRIDGE, A ;
DESOUZA, NM ;
BYDDER, GM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (04) :439-443
[2]   Fluid-attenuated inversion recovery (FLAIR) for assessment of cerebral infarction - Initial clinical experience in 50 patients [J].
BrantZawadzki, M ;
Atkinson, D ;
Detrick, M ;
Bradley, WG ;
Scidmore, G .
STROKE, 1996, 27 (07) :1187-1191
[3]  
DECOENE B, 1992, AM J NEURORADIOL, V13, P1555
[4]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[5]   Fast FLAIR of the brain: The range of appearances in normal subjects and its application to quantification of white-matter disease [J].
GawneCain, ML ;
Silver, NC ;
Moseley, IF ;
Miller, DH .
NEURORADIOLOGY, 1997, 39 (04) :243-249
[6]   SUSPECTED MULTIPLE-SCLEROSIS - MR-IMAGING WITH A THIN-SECTION PAST FLAIR PULSE SEQUENCE [J].
HASHEMI, RH ;
BRADLEY, WG ;
CHEN, DY ;
JORDAN, JE ;
QUERALT, JA ;
CHENG, AE ;
HENRIE, JN .
RADIOLOGY, 1995, 196 (02) :505-510
[7]   Mesial temporal sclerosis: Diagnosis with fluid-attenuated inversion-recovery versus spin-echo MR imaging [J].
Jack, CR ;
Rydberg, CH ;
Krecke, KN ;
Trenerry, MR ;
Parisi, JE ;
Rydberg, JN ;
Cascino, GD ;
Riederer, SJ .
RADIOLOGY, 1996, 199 (02) :367-373
[8]   CONTRAST OPTIMIZATION OF FLUID-ATTENUATED INVERSION-RECOVERY (FLAIR) IMAGING [J].
RYDBERG, JN ;
RIEDERER, SJ ;
RYDBERG, CH ;
JACK, CR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :868-877
[9]   INITIAL CLINICAL-EXPERIENCE IN MR-IMAGING OF THE BRAIN WITH A FAST FLUID-ATTENUATED INVERSION-RECOVERY PULSE SEQUENCE [J].
RYDBERG, JN ;
HAMMOND, CA ;
GRIMM, RC ;
ERICKSON, BJ ;
JACK, CR ;
HUSTON, J ;
RIEDERER, SJ .
RADIOLOGY, 1994, 193 (01) :173-180
[10]  
TAKANASHI J, 1995, AM J NEURORADIOL, V16, P1923