Form and functional repair of long bone using 3D-printed bioactive scaffolds

被引:50
作者
Tovar, Nick [1 ]
Witek, Lukasz [1 ]
Atria, Pablo [2 ]
Sobieraj, Michael [3 ]
Bowers, Michelle [1 ]
Lopez, Christopher D. [1 ,5 ]
Cronstein, Bruce N. [4 ]
Coelho, Paulo G. [1 ,5 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, 433 1st Ave,Room 842, New York, NY 10010 USA
[2] Univ Los Andes, Biomat Dept, Santiago, Chile
[3] Univ Penn, Dept Orthopaed Surg, Penn Presbyterian Med Ctr, Philadelphia, PA 19104 USA
[4] NYU, Sch Med, Dept Med, New York, NY 10010 USA
[5] NYU, Sch Med, Hansjorg Wyss Dept Plast Surg, New York, NY 10010 USA
关键词
3D printing; bioactive ceramic; calcium phosphate; in vivo; regeneration; scaffolds; HYDROXYAPATITE SCAFFOLDS; TISSUE; RECONSTRUCTION; OSSEOINTEGRATION; NANOINDENTATION; IMPLANTS; FIXATION; TITANIUM; DEFECTS; SURGERY;
D O I
10.1002/term.2733
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Injuries to the extremities often require resection of necrotic hard tissue. For large-bone defects, autogenous bone grafting is ideal but, similar to all grafting procedures, is subject to limitations. Synthetic biomaterial-driven engineered healing offers an alternative approach. This work focuses on three-dimensional (3D) printing technology of solid-free form fabrication, more specifically robocasting/direct write. The research hypothesizes that a bioactive calcium-phosphate scaffold may successfully regenerate extensive bony defects in vivo and that newly regenerated bone will demonstrate mechanical properties similar to native bone as healing time elapses. Robocasting technology was used in designing and printing customizable scaffolds, composed of 100% beta tri-calcium phosphate (beta-TCP), which were used to repair critical sized long-bone defects. Following full thickness segmental defects (similar to 11mmxfull thickness) in the radial diaphysis in New Zealand white rabbits, a custom 3D-printed, 100% beta-TCP, scaffold was implanted or left empty (negative control) and allowed to heal over 8, 12, and 24weeks. Scaffolds and bone, en bloc, were subjected to micro-CT and histological analysis for quantification of bone, scaffold and soft tissue expressed as a function of volume percentage. Additionally, biomechanical testing at two different regions, (a) bone in the scaffold and (b) in native radial bone (control), was conducted to assess the newly regenerated bone for reduced elastic modulus (E-r) and hardness (H) using nanoindentation. Histological analysis showed no signs of any adverse immune response while revealing progressive remodelling of bone within the scaffold along with gradual decrease in 3D-scaffold volume over time. Micro-CT images indicated directional bone ingrowth, with an increase in bone formation over time. Reduced elastic modulus (E-r) data for the newly regenerated bone presented statistically homogenous values analogous to native bone at the three time points, whereas hardness (H) values were equivalent to the native radial bone only at 24weeks. The negative control samples showed limited healing at 8weeks. Custom engineered beta-TCP scaffolds are biocompatible, resorbable, and can directionally regenerate and remodel bone in a segmental long-bone defect in a rabbit model. Custom designs and fabrication of beta-TCP scaffolds for use in other bone defect models warrant further investigation.
引用
收藏
页码:1986 / 1999
页数:14
相关论文
共 57 条
[1]   Mechanical properties of human bone surrounding plateau root form implants retrieved after 0.3-24 years of function [J].
Baldassarri, Marta ;
Bonfante, Estevam A. ;
Suzuki, Marcelo ;
Marin, Charles ;
Granato, Rodrigo ;
Tovar, Nick ;
Coelho, Paulo G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (07) :2015-2021
[2]  
Bose S., 2016, ANN BIOMEDICAL ENG, P1
[3]   Bone tissue engineering using 3D printing [J].
Bose, Susmita ;
Vahabzadeh, Sahar ;
Bandyopadhyay, Amit .
MATERIALS TODAY, 2013, 16 (12) :496-504
[4]  
CHAO EYS, 1989, CLIN ORTHOP RELAT R, P24
[5]   Osseointegration: Hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales [J].
Coelho, Paulo G. ;
Jimbo, Ryo ;
Tovar, Nick ;
Bonfante, Estevam A. .
DENTAL MATERIALS, 2015, 31 (01) :37-52
[6]   Osseointegration of metallic devices: Current trends based on implant hardware design [J].
Coelho, Paulo G. ;
Jimbo, Ryo .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2014, 561 :99-108
[7]   Physico/chemical characterization and preliminary human histology assessment of a β-TCP particulate material for bone augmentation [J].
Coelho, Paulo G. ;
Coimbra, Maria E. ;
Ribeiro, Cristiane ;
Fancio, Elizabeth ;
Higa, Olga ;
Suzuki, Marcelo ;
Marincola, Mauro .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2009, 29 (07) :2085-2091
[8]   A method for interpreting the data from depth-sensing indentation instruments [J].
Doerner, M. F. ;
Nix, W. D. .
JOURNAL OF MATERIALS RESEARCH, 1986, 1 (04) :601-609
[9]  
Dorlot JM., 1986, Trans.32nd Orthopedic Research Society, V11, P330
[10]  
Ellingsen JE, 2004, INT J ORAL MAX IMPL, V19, P659