Flicker-induced changes in retinal blood flow assessed by Doppler optical coherence tomography

被引:1
|
作者
Wang, Yimin [1 ,2 ]
Fawzi, Amani A. [3 ,4 ]
Tan, Ou [1 ,2 ]
Zhang, Xinbo [1 ,2 ]
Huang, David [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[2] Oregon Hlth & Sci Univ, Dept Ophthalmol, Portland, OR 97201 USA
[3] Univ So Calif, Doheny Eye Inst, Los Angeles, CA USA
[4] Univ So Calif, Dept Ophthalmol, Los Angeles, CA 90089 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 07期
关键词
VESSEL DIAMETER; NITRIC-OXIDE; NERVE; REPRODUCIBILITY; STIMULATION; DYNAMICS; VELOCITY; LIGHT;
D O I
10.1364/BOE.2.001852
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We used Doppler Fourier-domain optical coherence tomography (OCT) to investigate flicker-induced changes of total retinal blood flow. Total retinal blood flow was measured by summing flows in veins imaged in double-circular scans around the optic disc. In 3 healthy volunteers, total retinal blood flow was measured before and 10-15 seconds after 30 seconds of flicker stimulation. The average blood flow increased 22.2% (p = 0.002). The total venous and arterial vessel cross-sectional area increased 11.3% (p < 0.001) and +2.7% (p = 0.28) respectively. The average venous and arterial flow velocity were calculated indirectly by dividing total retinal blood flow by total venous and arterial cross-sectional areas. They also increased by 8.8% (p = 0.046) and 18.3% (p = 0.004), respectively. These results show that human retinal blood flow increases after visible flicker stimulation, and this could be measured with OCT. (C) 2011 Optical Society of America
引用
收藏
页码:1852 / 1860
页数:9
相关论文
共 50 条
  • [1] Changes in Retinal Blood Flow in Response to an Experimental Increase in IOP in Healthy Participants as Assessed With Doppler Optical Coherence Tomography
    Puchner, Stefan
    Schmidl, Doreen
    Ginner, Laurin
    Augustin, Marco
    Leitgeb, Rainer
    Szegedi, Stephan
    Stjepanek, Kristina
    Hommer, Nikolaus
    Kallab, Martin
    Werkmeister, Rene Marcel
    Schmetterer, Leopold
    Garhofer, Gerhard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (02)
  • [2] Flicker-induced changes in the choroidal blood flow and electroretinograms
    Lovasik, JV
    Kergoat, H
    Wajszilber, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U65 - U65
  • [3] Longitudinal Changes in Retinal Blood Flow in a Feline Retinal Vein Occlusion Model as Measured by Doppler Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Wada, Takanari
    Song, Youngseok
    Oomae, Tsuneaki
    Sogawa, Kenji
    Yoshioka, Takafumi
    Nakabayashi, Seigo
    Takahashi, Kengo
    Tani, Tomofumi
    Ishibazawa, Akihiro
    Ishiko, Satoshi
    Yoshida, Akitoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (02)
  • [4] Quality Control for Doppler Optical Coherence Tomography of Retinal Blood Flow
    Tan, O.
    Pappuru, R.
    Harris, A.
    Wang, Y.
    Sadda, S. R.
    Siesky, B. A.
    Huang, D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Impairment of flicker-induced increase in retinal blood flow in diabetic pigs
    Nagaoka, Taiji
    Yokota, Harumasa
    Watanabe, Masahisa
    Aso, Hiroshi
    Takase, Koyo
    Hanaguri, Junya
    Ohno, Akira
    Kushiyama, Akifumi
    Harino, Seiyo
    Yamagami, Satoru
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2024, 68 (04) : 362 - 366
  • [6] Visually evoked changes in the rat retinal blood flow measured with Doppler optical coherence tomography
    Tan, Bingyao
    Mason, Erik
    MacLellan, Ben
    Bizheva, Kostadinka
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [7] Effects of sildenafil on retinal blood flow and flicker-induced retinal vasodilatation in healthy subjects
    Polak, K
    Wimpissinger, B
    Berisha, F
    Georgopoulos, M
    Schmetterer, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) : 4872 - 4876
  • [8] Effects of sildenafil on retinal blood flow and flicker-induced retinal vasodilation in healthy subjects
    Wimpissinger, B
    Berisha, F
    Polak, K
    Schmetterer, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U67 - U67
  • [9] Longitudinal Measurements of Changes in Retinal Blood Flow in Feline Retinal Vein Occlusion Model Measured by Doppler Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Wada, Takanari
    Song, Y. S.
    Omae, Tsuneaki
    Sogawa, Kenji
    Yoshioka, Takafumi
    Nakabayashi, Seigo
    Takahashi, Kengo
    Tani, Tomofumi
    Ishibazawa, Akihiro
    Ishiko, Satoshi
    Yanagi, Yasuo
    Yoshida, Akitoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] Influence of flicker frequency on flicker-induced changes of retinal vessel diameter
    Polak, K
    Schmetterer, L
    Riva, CE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (08) : 2721 - 2726