Research of Differentiate Technology and Strategy of Lightning Protection for 500kV Transmission Line JG-type Tower

被引:0
作者
Yuan, Haiyan [1 ]
Yao, Jinxia [1 ]
Zhuang, Yanfei [2 ]
Yong, Jun [2 ]
机构
[1] State Grid Shandong Elect Power Res Inst, Jinan 250002, Peoples R China
[2] State Grid Shandong Elect Power Co, State Grid Shandong Elect Power Maintenance Co, Jinan 250000, Peoples R China
来源
2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) | 2014年
关键词
transmission line tower of JG-type; differentiate technology and strategy of lightning protection; lightning flashover risk evaluation; improved analytic hierarchy process(IAHP);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In view of the transmission line operating experience, the lightning trip rate of 500kV transmission line with JG-type("J" represent it is a corner tower and "G" represent the shape of tower) tower is relatively higher. In order to further improve the reliability of the power grid, and to take reasonable and effective measures in the light of transmission line characteristics, to achieve refined management of transmission lines, it is necessary to carry out differentiate technology and strategy of lightning protection for transmission line with JG-type corner tower. Firstly, Lightning flashover risk evaluation for transmission line with JG-type tower was carried out using the differentiate technology and strategy of lightning protection. The effects of topography and wind speed on the maximum lightning shielding failure current were analyzed. Considering the factors of tower structure, topography, wind speed and ground flash density, the lightning flashover risk was analyzed for the line with JG-type corner tower, and a preliminary lightning protection plan for JG-type tower was developed. Then the lightning protection measures were assessed technically and economically adopting the improved analytic hierarchy process(IAHP). Finally, the optimal lightning protection measures were determined. Through beforehand evaluation of the lightning protection measures, it is shown that if the developed lightning protection plan was implemented, the lightning flashover rate of transmission line with JG-type tower will be decreased by more than 50%.
引用
收藏
页码:301 / 306
页数:6
相关论文
共 10 条
  • [1] Fang Quan, 2012, J NANJING I TECHNOLO, V10, P61
  • [2] Luo Jieyi, 2010, GUANGDONG ELECT POWE, V23, P92
  • [3] [马御棠 Ma Yutang], 2012, [中国电力, Electric Power], V45, P18
  • [4] Qian Guan-jun, 2010, High Voltage Engineering, V36, P103
  • [5] Overview of Recent Progress in Lightning Research and Lightning Protection
    Rakov, Vladimir A.
    Rachidi, Farhad
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2009, 51 (03) : 428 - 442
  • [6] Wang Zhi-yong, 2011, High Voltage Engineering, V37, P622
  • [7] Xie Ping, 2012, ELECT POWER CONSTRUC, V33, P82
  • [8] [袁海燕 Yuan Haiyan], 2009, [电工技术学报, Transactions of China Electrotechnical Society], V24, P148
  • [9] Zhao Chun, 2011, High Voltage Engineering, V37, P3012
  • [10] Zhao Chun, 2011, High Voltage Engineering, V37, P290