Determination of phthalic acid esters in water samples using core-shell poly(dopamine) magnetic nanoparticles and gas chromatography tandem mass spectrometry

被引:31
|
作者
Gonzalez-Salamo, Javier [1 ]
Socas-Rodriguez, Barbara [1 ]
Hernandez-Borges, Javier [1 ]
Angel Rodriguez-Delgado, Miguel [1 ]
机构
[1] ULL, Fac Ciencias, Dept Quim, Unidad Dept Quim Analit, Avda Astrofis Fco Sdnchez S-N, San Cristobal De La Lagu 38206, Spain
关键词
Phthalic acid esters; Water; Magnetic-nanoparticles; Poly(dopamine); Gas chromatography; Tandem mass spectrometry; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; ENVIRONMENTAL WATER; ESTROGENIC COMPOUNDS; HUMAN EXPOSURE; POLYDOPAMINE; LIQUID; SORBENT; PRECONCENTRATION; MICROEXTRACTION;
D O I
10.1016/j.chroma.2017.11.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, the first application of core-shell poly(dopamine) magnetic nanoparticles as sorbent for the extraction of a group of eleven phthalic acid esters of interest (i.e. diethyl phthalate (DEP), dipropyl phthalate (DPP), dibutyl phthalate (DBP), bis-isopentyl phthalate (DIPP), bis-n-pentyl phthalate (DNPP), benzylbutyl phthalate (BBP), dicyclohexyl phthalate (DCHP), di-(2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), diisononyl phthalate (DINP) and diisodecyl phthalate (DIDP)) and one adipate (bis (2-ethylhexyl) adipate, DEHA) from different water samples (Milli-Q mineral, tap, pond and waste water) is proposed. Analysis were carried out by gas chromatography triple quadrupole tandem mass spectrometry. Parameters that affect the extraction performance were optimized following a step by step approach, being the optimum conditions the extraction of water at pH 6, with 60 mg of sorbent and the elution with 6 mL of dichloromethane. The methodology was validated for the five selected water samples using DBP-d(4) as internal standard. Determination coefficients of matrix-matched calibration curves were above 0.9904 in all cases while relative recovery values ranged between 71 and 120%, with relative standard deviation values below 19%. The limits of quantification of the method ranged between 9 and 20 ng/L. Matrix effects were found for most analytes and water samples. Real water samples were also analyzed, finding DEP and DBP at concentrations below 4.20 and 1.23 mu g/L, respectively, in mineral, tap and waste water. DCHP, DEHP and BBP were also found in some of the samples at concentrations below the LOQs of the method. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [11] Analysis of Organophosphate Esters in Sediment Samples Using Gas Chromatography-Tandem Mass Spectrometry
    Liu Shi-Long
    Zhang Hua
    Hu Xiao-Hui
    Qiu Yan-Ling
    Zhu Zhi-Liang
    Zhao Jian-Fu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 192 - 196
  • [12] Enrichment and determination of polybrominated diphenyl ethers in environmental water samples by magnetic solid-phase extraction with core-shell magnetic carbon microspheres before gas chromatography with mass spectrometry
    Zhou, Jia-Bin
    She, Xiao-Kun
    Xing, Han-Zhu
    Wang, Xia
    Zhao, Ru-Song
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (10) : 1955 - 1962
  • [13] Determination of 11 Phthalic Acid Esters in Soil by Accelerated Solvent Extraction-Liquid Chromatography Tandem Mass Spectrometry
    Yan Rui
    Shao Ming-Yuan
    Sun Chang-Hua
    Liu Xiao-Ling
    Song Da-Qian
    Zhang Han-Qi
    Yu Ai-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (06) : 897 - 903
  • [14] Analysis of phthalic acid esters in sea water and sea sand using polymer-coated magnetic nanoparticles as extraction sorbent
    Jimenez-Skrzypek, Gabriel
    Gonzalez-Salamo, Javier
    Angelica Varela-Martinez, Diana
    Angel Gonzalez-Curbelo, Miguel
    Hernandez-Borges, Javier
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1611
  • [15] Extraction of Phthalic Acid Esters and Di(2-ethylhexyl) Adipate from Tap and Waste Water Samples Using Chromabond® HLB as Sorbent Prior to Gas Chromatography-Mass Spectrometry Analysis
    Ortega-Zamora, Cecilia
    Gonzalez-Salamo, Javier
    Angelica Varela-Martinez, Diana
    Angel Gonzalez-Curbelo, Miguel
    Hernandez-Borges, Javier
    SEPARATIONS, 2020, 7 (02)
  • [16] Determination of pesticides in water samples by solid phase extraction and gas chromatography tandem mass spectrometry
    Ruiz-Gil, Laura
    Romero-Gonzalez, Roberto
    Frenich, Antonia Garrido
    Vidal, Jose L. Martinez
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (01) : 151 - 161
  • [17] Core-shell polydopamine magnetic nanoparticles as sorbent in micro-dispersive solid-phase extraction for the determination of estrogenic compounds in water samples prior to high-performance liquid chromatography-mass spectrometry analysis
    Socas-Rodriguez, Barbara
    Hernandez-Borges, Javier
    Salazar, Pedro
    Martin, Miriam
    Angel Rodriguez-Delgado, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1397 : 1 - 10
  • [18] Determination of household chemicals using gas chromatography and liquid chromatography with tandem mass spectrometry
    Trenholm, Rebecca A.
    Vanderford, Brett J.
    Drewes, Joerg E.
    Snyder, Shane A.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1190 (1-2) : 253 - 262
  • [19] Highly Sensitive Determination of Chlorophenols in Sea Water by Gas Chromatography-Tandem Mass Spectrometry
    Pokryshkin, S. A.
    Kosyakov, D. S.
    Kozhevnikov, A. Yu.
    Lakhmanov, D. E.
    Ul'yanovskii, N. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (10) : 991 - 998
  • [20] Determination of Phthalic Acid Esters in Seawater and Sediment by Solid-phase Microextraction and Gas Chromatography-Mass Spectrometry
    Zhang Ze-Ming
    Zhang Hong-Hai
    Li Jian-Long
    Yang Gui-Peng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (03) : 348 - 355