On-chip microelectrode array and in situ transient calibration for measurement of transient concentration gradients near surfaces of 2D cell cultures

被引:9
作者
Sridharan, Siddarth V. [1 ,2 ]
Rivera, Jose F. [1 ,2 ]
Nolan, James K. [2 ,3 ]
Alam, Muhammad A. [1 ,2 ]
Rickus, Jenna L. [3 ]
Janes, David B. [1 ,2 ]
机构
[1] Purdue Univ, Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
[3] Purdue Univ, Agr & Biol Engn, W Lafayette, IN 47907 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2018年 / 260卷
基金
美国国家科学基金会;
关键词
Microelectrode array; Amperometric sensing; Hydrogen peroxide; Concentration gradient; Concentration transients; 2D cell culture; Human astrocytes; Cellular gradients; Biosensors; Platinum electrodes; SCANNING ELECTROCHEMICAL MICROSCOPY; HYDROGEN-PEROXIDE; REAL-TIME; CONCENTRATION PROFILES; SPATIAL-RESOLUTION; CHROMAFFIN CELLS; RELEASE; GLUCOSE; H2O2; EXOCYTOSIS;
D O I
10.1016/j.snb.2017.12.194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric microelectrode arrays (MEAs) interrogate the concentration at multiple positions simultaneously and with sufficient sampling rates, thus being able to capture fast transient gradients. However, sensitivity variability issues in amperometric MEAs degrade the reliability of the measurements, particularly at the small concentration scales found in physiological studies. This paper describes the development of on-chip platinum amperometric MEAs and in situ transient calibration for reliable measurement of physiological transient concentration gradients. The designed MEA geometry facilitates positioning near a 2D cell culture setup, and the proposed in situ transient calibration minimizes the effects of sensitivity variability, thus allowing for calculation of gradients based on concentration differences between closely spaced electrodes. The effectiveness of the MEA and the in situ transient calibration was evaluated by measuring controllably-generated gradients, and then calculating the difference between experimental and simulated data using normalized time analysis. Gradients generated by periodic uptake intervals as fast as 150 ms followed by recovery intervals of 60 s were measured over a spatial range of 70 tim, with spatial resolution of 35 mu m, and sampling time and measurement time of 10 ms. Transient gradients of hydrogen peroxide were also measured above the surface of a 2D cell culture of human astrocytes, thus demonstrating the approach in actual physiological measurements. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:519 / 528
页数:10
相关论文
共 70 条
  • [1] Electrochemical Imaging of Dopamine Release from Three-Dimensional-Cultured PC12 Cells Using Large-Scale Integration-Based Amperometric Sensors
    Abe, Hiroya
    Ino, Kosuke
    Li, Chen-Zhong
    Kanno, Yusuke
    Inoue, Kumi Y.
    Suda, Atsushi
    Kunikata, Ryota
    Matsudaira, Masahki
    Takahashi, Yasufumi
    Shiku, Hitoshi
    Matsue, Tomokazu
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (12) : 6364 - 6370
  • [2] Consequences of relative cellular positioning on quorum sensing and bacterial cell-to-cell communication
    Alberghini, Sara
    Polone, Elisa
    Corich, Viviana
    Carlot, Milena
    Seno, Flavio
    Trovato, Antonio
    Squartini, Andrea
    [J]. FEMS MICROBIOLOGY LETTERS, 2009, 292 (02) : 149 - 161
  • [3] Monitoring in real time with a microelectrode the release of reactive oxygen and nitrogen species by a single macrophage stimulated by its membrane mechanical depolarization
    Amatore, C
    Arbault, S
    Bouton, C
    Coffi, K
    Drapier, JC
    Ghandour, H
    Tong, YH
    [J]. CHEMBIOCHEM, 2006, 7 (04) : 653 - 661
  • [4] Remote fluorescence Imaging of dynamic concentration profiles with micrometer resolution using a coherent optical fiber bundle
    Amatore, C
    Chovin, A
    Garrigue, P
    Servant, L
    Sojic, N
    Szunerits, S
    Thouint, L
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (24) : 7202 - 7210
  • [5] Analysis of individual biochemical events based on artificial synapses using ultramicroelectrodes: cellular oxidative burst
    Amatore, C
    Arbault, S
    Bruce, D
    de Oliveira, P
    Erard, M
    Vuillaume, M
    [J]. FARADAY DISCUSSIONS, 2000, 116 : 319 - 333
  • [6] Nitrogen monoxide and oxidative stress: composition and intensity of cellular oxidative bursts cocktail. A study through artificial electrochemical synapses on single human fibroblasts
    Amatore, C
    Arbault, S
    Bruce, D
    de Oliveira, P
    Erard, M
    Sojic, N
    Vuillaume, M
    [J]. ANALUSIS, 2000, 28 (06) : 506 - 517
  • [7] Vesicular exocytosis and microdevices - microelectrode arrays
    Amatore, Christian
    Delacotte, Jerome
    Guille-Collignon, Manon
    Lemaitre, Frederic
    [J]. ANALYST, 2015, 140 (11) : 3687 - 3695
  • [8] Scanning Electrochemical Microscopy
    Amemiya, Shigeru
    Bard, Allen J.
    Fan, Fu-Ren F.
    Mirkin, Michael V.
    Unwin, Patrick R.
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2008, 1 (01) : 95 - 131
  • [9] The extracellular matrix modulates H2O2 degradation and redox signaling in endothelial cells
    Bagulho, Ana
    Vilas-Boas, Filipe
    Pena, Andreia
    Peneda, Catarina
    Santos, Filipa C.
    Jeronimo, Ana
    de Almeida, Rodrigo F. M.
    Real, Carla
    [J]. REDOX BIOLOGY, 2015, 6 : 454 - 460
  • [10] Imaging concentration profiles of redox-active species with nanometric amperometric probes: Effect of natural convection on transport at microdisk electrodes
    Baltes, N
    Thouin, L
    Amatore, C
    Heinze, J
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (11) : 1431 - 1435