Electroanalytical studies on cobalt(II) selective potentiometric sensor based on bridge modified calixarene in poly(vinyl chloride)

被引:60
作者
Gupta, V. K. [1 ]
Jain, A. K. [1 ]
Al Khayat, M. [2 ]
Bhargava, S. K. [3 ]
Raisoni, J. R. [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Univ Sharjah, Coll Arts & Sci, Dept Chem, Sharjah, U Arab Emirates
[3] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3001, Australia
关键词
cobalt selective electrode; PVC membrane electrodes; thiacalixarene and potentiometric sensors;
D O I
10.1016/j.electacta.2008.02.085
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A bridge modified 4-tert-butylthiacalix[4]arene (I) has been employed as electroactive material in the preparation of cobalt selective sensor. Polyvinyl chloride (PVC)-based membranes of (I) using sodium tetraphenylborate (NaTPB) as anion discriminator and bis(2-ethylhexyl) sebacate (DOS), chloronaphthalene (CN), tri-n-butyl phosphate (TBP), o-nitrophenyl octyl ether (NPOE), tris(2-ethylhexyl)phosphate (TEHP)as plasticizers were prepared and investigated as cobalt selective sensors. A number of membranes of different compositions were prepared and investigated. The best performance was observed with the membrane having composition of 2:66:1.5:127 (mg)=I:NaTPB:PVC:NPOE. The potential response of this membrane is linear to Co2+ ions in the concentration range 5.3 x 10(-6) to 1.0 x 10(-1) M with near-Nernstian slope of 30.0 mV/decade of activity and a detection limit of similar to 0.3 ppm. This rnembrame also showed lowest response time of 10s and works satisfactorily in partially non-aqueous medium. The selectivity studies of this sensor, evaluated with fixed interference method and matched potential method, show that the sensor under consideration possesses excellent selectivity for Co2+ over a large number of mono-, bi- and trivalent cations such as Na+, K+, Ag+, Ca2+, Mg2+, Cu2+, Hg2+, Pb2+, Li+, Ba2+, Zn2+, Sr2+, Cr3+, Ni2+, etc. The sensor could be used as an indicator electrode in the quantification of Co2+ by potentiometric titration against EDTA as well as in determination of cobalt content in wastewater and beer samples. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5409 / 5414
页数:6
相关论文
共 25 条
[1]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[2]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[3]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[4]  
Ganjali MR, 2004, ANAL SCI, V20, P531
[5]  
Gupta V. K., 2004, PINSA-A (Proceedings of the Indian National Science Academy) Part A (Physical Sciences), V70, P399
[6]   A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N′-bis(salicylidene)-3,4-diaminotoluene [J].
Gupta, VK ;
Singh, AK ;
Mehtab, S ;
Gupta, B .
ANALYTICA CHIMICA ACTA, 2006, 566 (01) :5-10
[7]  
HASAN SSM, 1995, MIKROCHIM ACTA, V117, P121
[8]   Can thiacalixarene surpass calixarene? [J].
Iki, N ;
Miyano, S .
JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2001, 41 (1-4) :99-105
[9]   Macrocycle based membrane sensors for the determination of cobalt(II) ions [J].
Jain, AK ;
Gupta, VK ;
Singh, LP ;
Khurana, U .
ANALYST, 1997, 122 (06) :583-586
[10]   Ionophore-based ion-selective potentiometric and optical sensors [J].
Johnson, RD ;
Bachas, LG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) :328-341