Diagnostics used in commissioning the IUCF Cooler Injector Synchrotron

被引:0
作者
Ball, MS [1 ]
Friesel, DL [1 ]
Hamilton, BJ [1 ]
机构
[1] Indiana Univ, Cyclotron Facil, Bloomington, IN 47408 USA
来源
BEAM INSTRUMENTATION WORKSHOP | 1998年 / 451卷
关键词
D O I
10.1063/1.57027
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Several new diagnostics systems were designed to aid in the commissioning of the IUCF Cooler Injection Synchrotron (CIS). Among them are a time of flight measurement system (ToF), a multi-wire profile monitor system (Harp) and a beam position monitor system (BPM). Pulsed beam from the 7 MeV linear accelerator is monitored using the ToF system. Several removable Harps are mounted in the injection beamline and ring which are instrumental for tuning ring injection and accumulation. BPMs are placed at the entrance and exit of the four ring dipole magnets to facilitate beam centering during injection and ramping. Fast and slow BPM displays are available to the operator for these functions. These diagnostics and their uses for CIS ring commissioning will be discussed.
引用
收藏
页码:428 / 431
页数:4
相关论文
共 50 条
  • [31] COMMISSIONING OF THE 200 MEV INJECTOR LINAC FOR THE OXFORD-INSTR-IBM SYNCHROTRON LIGHT-SOURCE
    LETELLIER, P
    MEYRAND, G
    PERRAUDIN, C
    SETTY, A
    TRAN, DT
    TRONC, D
    KEMPSON, VC
    UYTHOVEN, JA
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1082 - 1084
  • [32] Electron cooling of bunched beams in the IUCF cooler: Intensity related effects
    Nagaitsev, S
    Ellison, MJ
    Ellison, TJP
    Ball, MS
    Derenchuk, V
    Hamilton, BJ
    Schwandt, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (01) : 32 - 36
  • [33] MICROTRON INJECTOR FOR A SYNCHROTRON
    WERNHOLM, O
    ARKIV FOR FYSIK, 1960, 16 (06): : 525 - 525
  • [34] POLARIZED INTERNAL GAS-TARGET FOR HYDROGEN AND DEUTERIUM AT THE IUCF COOLER RING
    DEZARN, WA
    DOSKOW, J
    HARDIE, JG
    MEYER, HO
    POLLOCK, RE
    VONPRZEWOSKI, B
    RINCKEL, T
    SPERISEN, F
    HAEBERLI, W
    LORENTZ, B
    RATHMANN, F
    ROSS, MA
    WISE, T
    PANCELLA, PV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (01) : 36 - 40
  • [36] THE COOLER-SYNCHROTRON COSY
    MAYERKUCKUK, T
    LECTURE NOTES IN PHYSICS, 1985, 243 : 567 - 573
  • [37] Initial commissioning experience with the LCLS injector
    Akre, R.
    Castro, J.
    Ding, Y.
    Dowell, D.
    Emma, P.
    Frisch, J.
    Gilevich, S.
    Hays, G.
    Hering, Ph.
    Huang, Z.
    Iverson, R.
    Krejcik, P.
    Limborg-Deprey, C.
    Loos, H.
    Mahnahri, A.
    Rivetta, C.
    Saleski, M.
    Schmerge, J.
    Schultz, D.
    Turner, J.
    Welch, J.
    White, W.
    Wu, J.
    Froelich, L.
    Limberg, T.
    Prat, E.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 3501 - +
  • [38] Diagnostics for commissioning LCLS
    Krejcik, P.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2481 - 2481
  • [39] The cooler synchrotron COSY facility
    Stockhorst, H
    Bechstedt, U
    Dietrich, J
    Maier, R
    Martin, S
    Prasuhn, D
    Schnase, A
    Schneider, H
    Tölle, R
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS, 1998, : 1048 - 1050
  • [40] Commissioning of the electron injector for the AWAKE experiment
    Kim, S-Y
    Doebert, S.
    Apsimon, O.
    Apsimon, R.
    Burt, G.
    Dayyani, M.
    Gessner, S.
    Gorgisyan, I
    Granados, E.
    Mazzoni, S.
    Moody, J. T.
    Turner, M.
    Williamson, B.
    Chung, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 953