Free-running temperature and potential for free cooling by ventilation: A case study

被引:28
作者
Inard, Christian [1 ]
Pfafferott, Jens [2 ]
Ghiaus, Christian [3 ]
机构
[1] Univ La Rochelle, LEPTIAB, F-17042 La Rochelle, France
[2] Fraunhofer Inst Solar Energy Syst ISE, D-79110 Freiburg, Germany
[3] Inst Natl Sci Appl, CETHIL, CNRS, UMR5008, F-69621 Villeurbanne, France
关键词
Office buildings; Passive-cooling; Thermal comfort; Free-running temperature; Ventilation; NIGHT VENTILATION; ENERGY; SIMULATION; DESIGN;
D O I
10.1016/j.enbuild.2011.06.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Free-cooling by ventilation is one of the most energy efficient techniques for cooling. When ventilation is used for cooling, variable airflow rates should to be used in order to achieve comfortable room temperatures and to minimize the energy demand for mechanical ventilation. Thus, free-cooling, requires, obviously, the existence of a potential for cooling and needs control mechanisms for the airflow. In this study, the free cooling potential by ventilation for office buildings is evaluated by the free-running temperature. The free-running temperature approach is based on the energy balance of heat gains and losses. It is adapted to evaluate the potential for free cooling by ventilation of office buildings for which the gains through the walls are negligible as compared to the internal and solar gains. The free-running temperature of each office room considers solar and internal heat gains, outdoor temperature, indoor temperatures and ventilation air flow rates. The approach is applied to 14 office rooms in a passively cooled office building in Germany and is used to estimate the potential and to evaluate the total energy saving by free cooling by ventilation. The good fit between monitoring data and calculation procedure proves that the free cooling potential can be accurately estimated by using the difference between the comfort limits, i.e. the target value of the indoor temperature, and the free-running temperature. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2705 / 2711
页数:7
相关论文
共 13 条
[1]  
ASHRAE, 2001, EN EST MOD METH ASHR
[2]  
CEN, 2012, EN15251
[3]  
Elkhuizen P. A., 2003, Building Services Engineering Research & Technology, V24, P191, DOI 10.1191/0143624403bt071oa
[4]   Experimental estimation of building energy performance by robust regression [J].
Ghiaus, C .
ENERGY AND BUILDINGS, 2006, 38 (06) :582-587
[5]   Equivalence between the load curve and the free-running temperature in energy estimating methods [J].
Ghiaus, C .
ENERGY AND BUILDINGS, 2006, 38 (05) :429-435
[6]   Free-running building temperature and HVAC climatic suitability [J].
Ghiaus, C .
ENERGY AND BUILDINGS, 2003, 35 (04) :405-411
[7]   Energetic analysis of a passive solar design, incorporated in a courtyard after refurbishment, using an innovative cover component based in a sawtooth roof concept [J].
Heras, MR ;
Jiménez, MJ ;
San Isidro, MJ ;
Zarzalejo, LF ;
Pérez, M .
SOLAR ENERGY, 2005, 78 (01) :85-96
[8]  
Kalz D., 2010, P C AD CHANG NEW THI
[9]   Statistical simulation of user behaviour in low-energy office buildings [J].
Pfafferott, J. ;
Herkel, S. .
SOLAR ENERGY, 2007, 81 (05) :676-682
[10]   Design of passive cooling by night ventilation:: evaluation of a parametric model and building simulation with measurements [J].
Pfafferott, J ;
Herkel, S ;
Jäschke, M .
ENERGY AND BUILDINGS, 2003, 35 (11) :1129-1143