Trace manganese detection via differential pulse cathodic stripping voltammetry using disposable electrodes: additively manufactured nanographite electrochemical sensing platforms

被引:40
作者
Rocha, Diego P. [1 ,2 ]
Foster, Christopher W. [1 ]
Munoz, Rodrigo A. A. [2 ]
Buller, Gary A. [1 ]
Keefe, Edmund M. [1 ]
Banks, Craig E. [1 ]
机构
[1] Manchester Metropolitan Univ, Fac Sci & Engn, Chester St, Manchester M1 5GD, Lancs, England
[2] Univ Fed Uberlandia, Inst Chem, BR-38400902 Uberlandia, MG, Brazil
基金
英国工程与自然科学研究理事会;
关键词
SCREEN-PRINTED ELECTRODES; NATURAL-WATERS; ELECTROANALYSIS; ENHANCE; SENSORS; MN(II);
D O I
10.1039/d0an00018c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Additive manufacturing is a promising technology for the rapid and economical fabrication of portable electroanalytical devices. In this paper we seek to determine how our bespoke additive manufacturing feedstocks act as the basis of an electrochemical sensing platform towards the sensing of manganese(ii) via differential pulse cathodic stripping voltammetry (DPCSV), despite the electrode comprising only 25 wt% nanographite and 75 wt% plastic (polylactic acid). The Additive Manufactured electrodes (AM-electrodes) are also critically compared to graphite screen-printed macroelectrodes (SPEs) and both are explored in model and real tap-water samples. Using optimized DPCSV conditions at pH 6.0, the analytical outputs using the AM-electrodes are as follows: limit of detection, 1.6 x 10(-9) mol L-1 (0.09 mu g L-1); analytical sensitivity, 3.4 mu A V mu mol(-1) L; linear range, 9.1 x 10(-9) mol L-1 to 2.7 x 10(-6) mol L-1 (R-2 = 0.998); and RSD 4.9% (N = 10 for 1 mu mol L-1). These results are compared to screen-printed macroelectrodes (SPEs) giving comparable results providing confidence that AM-electrodes can provide the basis for useful electrochemical sensing platforms. The proposed electroanalytical method (both AM-electrodes and SPEs) is shown to be successfully applied for the determination of manganese(ii) in tap water samples and in the analysis of a certified material (drinking water). The proposed method is feasible to be applied for in-loco analyses due to the portability of sensing; in addition, the use of AM-printed electrodes is attractive due to their low cost.
引用
收藏
页码:3424 / 3430
页数:7
相关论文
共 41 条
[11]   Can the mechanical activation (polishing) of screen-printed electrodes enhance their electroanalytical response? [J].
Cumba, Loanda R. ;
Foster, Christopher W. ;
Brownson, Dale A. C. ;
Smith, Jamie P. ;
Iniesta, Jesus ;
Thakur, Bhawana ;
do Carmo, Devaney R. ;
Banks, Craig E. .
ANALYST, 2016, 141 (09) :2791-2799
[12]   Voltammetry determination of trace manganese with pretreatment glassy carbon electrode by linear sweep voltammetry [J].
Di, JW ;
Zhang, F .
TALANTA, 2003, 60 (01) :31-36
[13]   Stripping voltammetry method for determination of manganese as complex with oxine at the carbon paste electrode with and without modification with montmorillonite clay [J].
El-Desoky, Hanaa S. ;
Ismail, Iqbal M. ;
Ghoneim, Mohamed M. .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (12) :3153-3167
[14]   Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes [J].
Filipe, OMS ;
Brett, CMA .
TALANTA, 2003, 61 (05) :643-650
[15]   Additively manufactured graphitic electrochemical sensing platforms [J].
Foster, Christopher W. ;
Elbardisy, Hadil M. ;
Down, Michael P. ;
Keefe, Edmund M. ;
Smith, Graham C. ;
Banks, Craig E. .
CHEMICAL ENGINEERING JOURNAL, 2020, 381
[16]   Ultraflexible Screen-Printed Graphitic Electroanalytical Sensing Platforms [J].
Foster, Christopher W. ;
Metters, Jonathan P. ;
Kampouris, Dimitrios K. ;
Banks, Craig E. .
ELECTROANALYSIS, 2014, 26 (02) :262-274
[17]   Exploring the electrical wiring of screen-printed configurations utilised in electroanalysis [J].
Galdino, Flavia E. ;
Foster, Christopher W. ;
Bonacin, Juliano A. ;
Banks, Craig E. .
ANALYTICAL METHODS, 2015, 7 (03) :1208-1214
[18]   On-site monitoring of trace levels of free manganese in sea water via sonoelectroanalysis using a boron-doped diamond electrode [J].
Goodwin, A ;
Lawrence, AL ;
Banks, CE ;
Wantz, F ;
Omanovic, D ;
Komorsky-Lovric, E ;
Compton, RG .
ANALYTICA CHIMICA ACTA, 2005, 533 (02) :141-145
[19]   Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses [J].
Hart, JP ;
Wring, SA .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (02) :89-103
[20]  
In J. J., 2000, ANAL SCI, V16, P317