Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair

被引:25
作者
Baril, Donald T. [1 ]
Silverberg, Daniel [1 ]
Ellozy, Sharif H. [1 ]
Carroccio, Alflo [1 ]
Jacobs, Tikva S. [1 ]
Sachdev, Ulka [1 ]
Teodorescu, Victoria J. [1 ]
Lookstein, Robert A. [1 ]
Marin, Michael L. [1 ]
机构
[1] Mt Sinai Sch Med, Dept Surg, Div Vasc Surg, New York, NY 10029 USA
关键词
D O I
10.1016/j.avsg.2007.10.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Despite high initial technical success, the long-term durability of endovascular abdominal aortic aneurysm repair (EVAR) continues to be a concern. Following EVAR, patients can experience endoleaks, device migration, device fractures, or aneurysm growth that may require intervention. The purpose of this study was to review all patients treated with secondary enclovascular devices at our institution for failed EVAR procedures. Over an 8-year period, 988 patients underwent EVAR, of whom 42 (4.3%) required secondary interventions involving placement of additional enclovascular devices. Data regarding patient characteristics, aneurysm size, initial device type, time until failure, failure etiology, secondary interventions, and outcomes were reviewed. The mean time from initial operation until second operation was 34.1 months. Failures included type I endoleaks in 38 patients (90.5%), type III endoleaks in two patients (4.8%), and enlarging aneurysms without definite encloleaks in two patients (4.8%). The overall technical success rate for secondary repair was 92.9% (39/42). Perioperative complications occurred in nine patients (21.4%), including wound complications (n = 6), cerebrovascular accident (CVA) (n = 1), foot drop (n = 1), and death (n = 1). Mean follow-up following secondary repair was 16.4 months (range 1-50). Eighty-six percent of patients treated with aorlouni-iliac devices had successful repairs compared to 45% of patients treated with proximal cuffs. Ten patients (23.8%) had persistent or recurrent type I or type III encloleaks following revision. Of these, four had tertiary interventions, including two patients who had additional devices placed. Failures following EVAR occur in a small but significant number of patients. When anatomically possible, enclovascular revision offers a safe means of treating these failures. Aortouni-iliac devices appear to offer a more durable repair than the proximal cuff for treatment of proximal type I endoleaks. Midterm results indicate that these patients may require additional procedures but have a low rate of aneurysm-related mortality. Longer-term follow-up is necessary to determine the durability of these enclovascular revisions.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 50 条
[41]   Endovascular treatment of failed prior abdominal aortic aneurysm repair [J].
Faries, PL ;
Won, J ;
Morrissey, NJ ;
Briggs, VL ;
Cadot, H ;
Carroccio, A ;
Teodorescu, V ;
Chae, KS ;
Hollier, LH ;
Marin, ML .
ANNALS OF VASCULAR SURGERY, 2003, 17 (01) :43-48
[42]   Endovascular stent-graft repair of thoracic aortic aneurysms - Discussion [J].
Anderson, RP ;
Mitchell, RS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1060-1062
[43]   Emergency endovascular stent-graft repair for thoracic aortic injury [J].
Hanson, JA ;
Brooks, DM ;
Raman, JS .
MEDICAL JOURNAL OF AUSTRALIA, 2002, 176 (03) :111-112
[44]   Endovascular stent-graft as a bridge to definitive repair of aortic trauma [J].
Hoffer E. ;
Karmy-Jones R. ;
Gibson K. ;
Borsa J.J. .
Emergency Radiology, 2001, 8 (4) :233-236
[45]   Endovascular stent-graft prosthesis of aortic aneurysm [J].
Ince, H ;
Nienaber, CA .
ZEITSCHRIFT FUR KARDIOLOGIE, 2001, 90 (01) :67-72
[46]   Repair of Abdominal Aortic Aneurysm by Endovascular Stent-Graft Implantation in a Patient with Severe Chronic Obstructive Pulmonary Disease [J].
Karabay, Ozalp ;
Men, Suleyman ;
Aykut, Koray ;
Gulcu, Aytac ;
Silistreli, Erdem ;
Erdal, Cenk ;
Algin, Ibrahim ;
Acikel, Unal .
TURKISH THORACIC JOURNAL, 2006, 7 (02) :141-144
[47]   Technique for Fenestrated Stent-Graft Implantation as a Proximal Extension to a Previous Fenestrated Endovascular Repair for Abdominal Aortic Aneurysm [J].
Spanos, Konstantinos ;
Tsilimparis, Nikolaos ;
Heidemann, Franziska ;
Rohlffs, Fiona ;
Behrendt, Christian-Alexander ;
Debus, Eike Sebastian ;
Koelbel, Tilo .
JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (01) :16-20
[48]   Endovascular Treatment of Late in—Stent-Graft Dissection After Thoracic Endovascular Aneurysm Repair [J].
Ivan Vulev ;
Andrej Klepanec ;
Tibor Balázs ;
Marián Holomáň .
CardioVascular and Interventional Radiology, 2011, 34 :864-867
[49]   Endovascular stent-graft repair of large abdominal aortic aneurysms in high risk patients [J].
Chuter, TA ;
Gordon, RL ;
LaBerge, JM ;
Ring, EJ ;
Kerlan, RK ;
Reilly, LM .
RADIOLOGY, 1997, 205 :78-78
[50]   Endovascular repair of abdominal aortic aneurysms: Stent-graft fixation across the visceral arteries [J].
Burks, JA ;
Faries, PL ;
Gravereaux, EC ;
Hollier, LH ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (01) :109-113