Design of an autofocus capsule endoscope system and the corresponding 3D reconstruction algorithm

被引:2
作者
Zhang, Wei [1 ]
Jin, Yi-Tao [1 ]
Guo, Xin [1 ]
Su, Jin-Hui [1 ]
You, Su-Ping [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Opt Elect & Comp Engn, Shanghai Key Lab Modern Opt Syst, Engn Res Ctr Opt Instrument & Syst,Minist Educ, Shanghai 200093, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
IMAGE; SHAPE;
D O I
10.1364/JOSAA.33.001970
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A traditional capsule endoscope can only take 2D images, and most of the images are not clear enough to be used for diagnosing. A 3D capsule endoscope can help doctors make a quicker and more accurate diagnosis. However, blurred images negatively affect reconstruction accuracy. A compact, autofocus capsule endoscope system is designed in this study. Using a liquid lens, the system can be electronically controlled to autofocus, and without any moving elements. The depth of field of the system is in the 3-100 mm range and its field of view is about 110 degrees. The images captured by this optical system are much clearer than those taken by a traditional capsule endoscope. A 3D reconstruction algorithm is presented to adapt to the zooming function of our proposed system. Simulations and experiments have shown that more feature points can be correctly matched and a higher reconstruction accuracy can be achieved by this strategy. (C) 2016 Optical Society of America
引用
收藏
页码:1970 / 1977
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 2003, MULTIPLE VIEW GEOMET
[2]  
Arie K., 2008, 3D SURFACE RECONSTRU, P61
[3]  
Ayoub J., 2010, 2010 International Conference of Soft Computing and Pattern Recognition (SoCPaR 2010), P198, DOI 10.1109/SOCPAR.2010.5686096
[4]  
Bo Sun, 2010, 2010 International Conference on Audio, Language and Image Processing (ICALIP), P607, DOI 10.1109/ICALIP.2010.5684391
[5]   An integrated vision system with autofocus for wireless capsular endoscopy [J].
Cavallotti, C. ;
Piccigallo, M. ;
Susilo, E. ;
Valdastri, P. ;
Menciassi, A. ;
Dario, Paolo .
SENSORS AND ACTUATORS A-PHYSICAL, 2009, 156 (01) :72-78
[6]   A study of optical design and optimization of zoom optics with liquid lenses through modified genetic algorithm [J].
Fang, Yi-Chin ;
Tsai, Cheng-Mu ;
Chung, Cheng-Lun .
OPTICS EXPRESS, 2011, 19 (17) :16291-16302
[7]   RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY [J].
FISCHLER, MA ;
BOLLES, RC .
COMMUNICATIONS OF THE ACM, 1981, 24 (06) :381-395
[8]  
Guo X., 2015, ACTA PHOTONICA SIN, V44, P185
[9]   Wireless capsule endoscopy [J].
Iddan, G ;
Meron, G ;
Glukhovsky, A ;
Swain, P .
NATURE, 2000, 405 (6785) :417-417
[10]  
Jin Zhou, 2008, 2008 IEEE Computer Society Conference on Computer Vision and Pattern Recognition Workshops (CVPR Workshops), P1, DOI 10.1109/CVPRW.2008.4563010