Repeatability of Internal Aberrometry with a New Simultaneous Capture Aberrometer/Corneal Topographer

被引:12
作者
Gifford, Paul [1 ]
Swarbrick, Helen A. [1 ]
机构
[1] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
internal eye aberration; ocular aberration; corneal topography; Discovery; OPD Scan 3; WAVE-FRONT ABERRATIONS; HIGHER-ORDER ABERRATIONS; OPTICAL ABERRATIONS; CORNEAL ABERRATIONS; HUMAN EYE; MONOCHROMATIC ABERRATIONS; CORRELATION-COEFFICIENTS; SPHERICAL-ABERRATION; MEASUREMENT ERROR; ANTERIOR CORNEAL;
D O I
10.1097/OPX.0b013e31825017c4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare repeatability of internal eye aberrations derived from aberrometry and corneal topography (CT) measured simultaneously by the Innovative Visual Systems Discovery, against time displaced but same instrument measurement (Nidek OPD-Scan 3), and time displaced different instrument measurement (Medmont E300 and Imagine Eyes irx3). Methods. Three aberrometry and CT measurements were captured with each instrument, except for the OPD-Scan 3 where three aberrometry scans were followed by a single CT. Measurements were repeated across 2 days. Corneal surface Zernike coefficients were derived from CT and subtracted from aberrometry to establish internal aberration coefficients. For the OPD-Scan 3, internal Zernike coefficients were derived by the instrument's software. Repeatability for second-order root mean square (RMS), spherical aberration, coma RMS, trefoil RMS, and the refraction components M, J(0), and J(45) were assessed using intraclass correlation coefficient (ICC). Results. Intrasession repeatability was similar between the Discovery and E300/irx3, with the E300/irx3 slightly more repeatable for second-order RMS. Across days, the Discovery was most repeatable for second-order RMS (ICC 0.98) followed by the E300/irx3 (ICC 0.96) and OPD-Scan 3 (ICC 0.88). All instruments were less repeatable for higher order aberrations with only the Discovery moderately repeatable for spherical aberration and trefoil RMS (both ICC >= 0.75). The Discovery was highly repeatable for all derived refractive components (ICC >= 0.96). The E300/irx3 was highly repeatable for M (ICC 0.98) and moderately repeatable for J(0) (ICC 0.89). The OPD-Scan 3 was highly repeatable for the M component (ICC 0.98) but not repeatable for the cylindrical components. Conclusions. The Discovery was highly repeatable for second-order RMS and derived refractive components. The lower repeatability for internal higher order aberrations measured with all instruments suggests caution in their use until further work is carried out to investigate sources of error and to develop methods to improve repeatability. (Optom Vis Sci 2012;89:929-938)
引用
收藏
页码:929 / 938
页数:10
相关论文
共 51 条
[1]  
Applegate RA, 2000, J REFRACT SURG, V16, P507
[2]   Visual acuity as a function of Zernike mode and level of root mean square error [J].
Applegate, RA ;
Ballentine, C ;
Gross, H ;
Sarver, EJ ;
Sarver, CA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) :97-105
[3]   Neural compensation for the eye's optical aberrations [J].
Artal, P ;
Chen, L ;
Fernández, EJ ;
Singer, B ;
Manzanera, S ;
Williams, DR .
JOURNAL OF VISION, 2004, 4 (04) :281-287
[4]   Compensation of corneal aberrations by the internal optics in the human eye [J].
Artal, Pablo ;
Guirao, Antonio ;
Berrio, Esther ;
Williams, David R. .
JOURNAL OF VISION, 2001, 1 (01) :1-8
[5]   Anterior corneal and internal contributions to peripheral aberrations of human eyes [J].
Atchison, DA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2004, 21 (03) :355-359
[6]   Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology [J].
Benard, Yohann ;
Lopez-Gil, Norberto ;
Legras, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12) :2129-2138
[7]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[8]   Measurement error [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 312 (7047) :1654-1654
[9]   Corneal aberrations and reading [J].
Buehren, T ;
Collins, MJ ;
Carney, L .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) :159-166
[10]   Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye [J].
Carvalho, LA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) :1915-1926