In vitro comparison of three techniques for ventriculo-aortic junction annuloplasty

被引:32
作者
de Kerchove, Laurent [1 ]
Vismara, Riccardo [2 ,3 ]
Mangini, Andrea [3 ,4 ]
Fiore, Gianfranco Beniamino [2 ,3 ]
Price, Joel [1 ]
Noirhomme, Philippe [1 ]
Antona, Carlo [3 ,4 ]
El Khoury, Gebrine [1 ]
机构
[1] Catholic Univ Louvain, St Luc Univ Hosp, Div Cardiothorac & Vasc Surg, Brussels, Belgium
[2] Politecn Milan, Dept Bioengn, Milan, Italy
[3] Fdn Res Cardiac Surg, FoRcardioLab, Milan, Italy
[4] L Sacco Univ Hosp, Div Cardiovasc Surg, Milan, Italy
关键词
Aortic valve regurgitation; Aortic valve repair; Annuloplasty; SURGICAL-CORRECTION; VALVE; REIMPLANTATION; REGURGITATION; REPLACEMENT; OPERATIONS; RING;
D O I
10.1093/ejcts/ezr237
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In aortic valve repair, reduction and stabilization of the ventriculo-aortic junction (VAJ) is generally recommended. In this in vitro study, we compare three techniques of annuloplasty: the subcommissural annuloplasty (SCA), the internal ring (IR) and the external ring (ER) annuloplasty. Ten fresh porcine aortic valve preparations were tested in a pulsatile mock loop. Each sample was tested untreated (baseline: B). The annuloplasty techniques were then performed successively in each sample. Each technique was tested, then removed and the following technique performed. SCA was applied at 50% of interleaflet triangle height; the ER and IR were applied with a moderate reduction (15-20%) of the VAJ. Hydrodynamic, video and echographic parameters were collected. Flow rate and arterial pressure were maintained consistently between groups. Effective orifice area decreased significantly with each annuloplasty technique compared with baseline (P < 0.001). Mean transvalvular pressure drop was significantly higher in the ER and IR vs SCA (P = 0.007). Annuloplasty reduced valve opening and closing time in comparison to baseline. Echocardiography confirmed that the VAJ experienced a greater reduction with the ER and IR vs SCA. A narrowing of the lower third of the sinuses of Valsalva was observed after the ER, and subvalvular narrowing was observed after the IR. Valve coaptation increased with all annuloplasty techniques. The three annuloplasty techniques examined demonstrated differential effects on aortic valve function and root morphology. The ER and IR have greater potential to reduce VAJ diameter in comparison to SCA. The IR induced a subvalvular remodelling of the VAJ, whereas the ER induced a paravalvular remodelling.
引用
收藏
页码:1117 / 1124
页数:8
相关论文
共 26 条
  • [1] Aortic valve repair leads to a low incidence of valve-related complications
    Aicher, Diana
    Fries, Roland
    Rodionycheva, Svetlana
    Schmidt, Kathrin
    Langer, Frank
    Schaefers, Hans-Joachim
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (01) : 127 - 132
  • [2] [Anonymous], EUR J CARDIOTHORAC S
  • [3] [Anonymous], 2008, ANN THORAC SURG
  • [4] Boodhwani Munir, 2009, Interact Cardiovasc Thorac Surg, V8, P584, DOI 10.1510/icvts.2008.197574
  • [5] Repair-oriented classification of aortic insufficiency: Impact on surgical techniques and clinical outcomes
    Boodhwani, Munir
    de Kerchove, Laurent
    Glineur, David
    Poncelet, Alain
    Rubay, Jean
    Astarci, Parla
    Verhelst, Robert
    Noirhomme, Philippe
    El Khoury, Gebrine
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (02) : 286 - 294
  • [6] COSGROVE DM, 1991, J THORAC CARDIOV SUR, V102, P571
  • [7] Long-term results of aortic valve-sparing operations for aortic root aneurysm
    David, Tirone E.
    Feindel, Christopher M.
    Webb, Gary D.
    Colman, Jack M.
    Armstrong, Susan
    Maganti, Manjula
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (02) : 347 - 353
  • [8] Valve sparing-root replacement with the reimplantation technique to increase the durability of bicuspid aortic valve repair
    de Kerchove, Laurent
    Boodhwani, Munir
    Glineur, David
    Vandyck, Michel
    Vanoverschelde, Jean-Louis
    Noirhomme, Philippe
    El Khoury, Gebrine
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (06) : 1430 - U544
  • [9] Duran C G, 1988, J Card Surg, V3, P23, DOI 10.1111/j.1540-8191.1988.tb00214.x
  • [10] Remodeling or reimplantation for valve-sparing aortic root surgery?
    Erasmi, Armin W.
    Sievers, Hans-H.
    Bechtel, J. F. Matthias
    Hanke, Thorsten
    Stierle, Ulrich
    Misfeld, Martin
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (02) : S752 - S756