Measurement on falling film thickness distribution around horizontal tube with laser-induced fluorescence technology

被引:93
|
作者
Chen, Xue [1 ]
Shen, Shengqiang [1 ]
Wang, Yaoxuan [1 ]
Chen, Juexian [1 ]
Zhang, Jieshan [1 ]
机构
[1] Dalian Univ Technol, Key Lab Liaoning Prov Desalinat, Dalian 116024, Peoples R China
关键词
Horizontal tube falling film; Film thickness; Laser-induced fluorescence; Seawater; EVAPORATION; WATER;
D O I
10.1016/j.ijheatmasstransfer.2015.05.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
The laser-induced fluorescence technology is used to measure the horizontal tube falling film thickness of pure water and natural seawater with 2.66% salinity. This experiment focuses on the film thickness distribution characteristics outside 19 mm and 25.4 mm outside diameter Al-brass tubes in column flow with the tube spacing ranging from 20 mm to 40 mm and the Reynolds number varying from 184 to 368. The fluorescent in liquid is induced by the laser. And the images of gas liquid interface are captured by the digital camera. The quantitative descriptions of the liquid film thickness around the horizontal tube are obtained by the image processing technology. The results show that the film thickness increases with Reynolds number and decreases with tube spacing. In the axial direction, the thickness of the film increases with the distance from the section of liquid column center and maximized at the middle of two adjacent liquid columns. In the circumferential direction, the thickness of the film decreases until it reaches the minimal value near phi = 90 degrees and then increases. The comparison of film thickness between water and seawater is also presented. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:707 / 713
页数:7
相关论文
共 50 条
  • [41] Laser induced fluorescence measurement of liquid film thickness and variation in Taylor flow
    Vignesh, K.
    Vasudevan, C.
    Arunkumar, S.
    Suwathy, R.
    Venkatesan, M.
    EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2018, 70 : 85 - 92
  • [42] Numerical study of falling film thickness over fully wetted horizontal round tube
    Qiu, Qinggang
    Zhu, Xiaojing
    Mu, Lin
    Shen, Shengqiang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 84 : 893 - 897
  • [43] Falling film thickness measurement using CFD analysis over horizontal tubesy
    Korde, N.U.
    Pise, A.T.
    Gunavant, P.S.
    International Journal of Fluid Mechanics Research, 2013, 41 (06) : 536 - 546
  • [44] Laser-induced fluorescence for film thickness mapping in pure sliding lubricated, compliant, contacts
    Myant, C.
    Reddyhoff, T.
    Spikes, H. A.
    TRIBOLOGY INTERNATIONAL, 2010, 43 (11) : 1960 - 1969
  • [45] Falling Film Thickness Measurement Using CFD Analysis over Horizontal Tubes
    Korde, N. U.
    Pise, A. T.
    Gunavant, P. S.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2014, 41 (06) : 526 - 535
  • [46] Simulation on the distribution of heat transfer parameters in a horizontal tube falling film evaporator
    Shen, Sheng-Qiang (zzbshen@dlut.edu.cn), 1600, Science Press (35):
  • [47] Parametric distribution of the condensation and evaporation processes in horizontal tube falling film evaporator
    Gong, Luyuan
    Sun, Genming
    Guo, Yali
    Shen, Shengqiang
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [48] Asymmetric distribution of falling film solution flowing on hydrophilic horizontal round tube
    Ji, Ge
    Wu, Jiafeng
    Chen, Yaping
    Ji, Guangju
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 78 : 83 - 92
  • [49] Local measurement of oxygen transfer around a single bubble by planar laser-induced fluorescence
    Dani, Adil
    Guiraud, Pascal
    Cockx, Arnaud
    CHEMICAL ENGINEERING SCIENCE, 2007, 62 (24) : 7245 - 7252
  • [50] Investigation of the flow characteristics of a falling film along an inclined surface with planar laser-induced fluorescence method
    Chen, X.
    Wang, C.
    Song, Y.
    Ouyang, X. L.
    Jiang, P. X.
    Shen, S. Q.
    DESALINATION AND WATER TREATMENT, 2017, 89 : 87 - 93