Patient-specific instrumentation improves functional kinematics of minimally-invasive total knee replacements as revealed by computerized 3D fluoroscopy

被引:7
作者
Shih, Kao-Shang [1 ,2 ]
Lin, Cheng-Chung [3 ]
Lu, Hsuan-Lun [4 ]
Fu, Yang-Chieh [4 ]
Lin, Cheng-Kai [4 ]
Li, Song-Ying [4 ]
Lu, Tung-Wu [4 ,5 ]
机构
[1] Fu Jen Catholic Univ, Sch Med, New Taipei, Taiwan
[2] Shin Kong Wu Ho Su Mem Hosp, Dept Orthoped, Taipei, Taiwan
[3] Fu Jen Catholic Univ, Dept Elect Engn, New Taipei, Taiwan
[4] Natl Taiwan Univ, Dept Biomed Engn, Taipei, Taiwan
[5] Natl Taiwan Univ, Sch Med, Dept Orthopaed Surg, Taipei, Taiwan
关键词
Isolated knee exercise; Three-dimensional fluoroscopy; Surface kinematics; Joint biomechanics; IN-VIVO KINEMATICS; MOBILE-BEARING; ARTHROPLASTY; SURGERY; FLEXION; SURVIVORSHIP; ACCURACY;
D O I
10.1016/j.cmpb.2019.105250
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objectives: Minimally-invasive total knee arthroplasty (MIS-TKA) has demonstrated very good short-term success, but its mid- to long-term results remain inconclusive. The success may be related to the tradeoff between a small incision and accurate positioning of the implant components. Patient-specific instrumentation (PSI) aims to improve the accuracy in restoring the knee axis and the clinical outcomes for MIS-TKA but the results are yet to be confirmed by accurate assessment during functional activities. The purpose of the current study was to measure and compare the in vivo three-dimensional (3D) rigid-body and surface kinematics of MIS-TKA implanted with and without PSI during isolated knee active flexion/extension and sit-to-stand using state-of-the-art 3D model-based fluoroscopy technology. Methods: Ten patients treated for advanced medial knee osteoarthritis by MIS-TKA without PSI (non-PSI group) and nine with PSI (PSI group) participated in the current study. Each subject performed nonweight-bearing knee flexion/extension and sit-to-stand tasks while the motion of the prosthetic knee was under bi-plane fluoroscopy surveillance. The computer models of each of the knee prosthesis components were registered to the measured fluoroscopy images for each time frame via a novel validated 3D fluoroscopy method. Non-parametric 1-tailed Mann-Whitney tests were performed to detect the differences in the joint and surface kinematic variables every 10 degrees of knee flexion between the non-PSI and PSI groups. The 1-tailed significance level was at alpha = 0.05. Results: The PSI group showed clear, coupled flexion/internal rotation during activities, while the non-PSI group remained roughly at an externally rotated position with slight internal rotations. The coupled rotation in the PSI group was accompanied by an anterior displacement of the medial contact and a posterior displacement of the lateral contact, which was different from the screw-home mechanism. Neither of the two groups showed the normal roll-back phenomenon, i.e., posterior translation of the femur relative to the tibia during knee flexion. Conclusions: With the state-of-the-art 3D fluoroscopy method, differences in both the rigid-body and surface kinematics of the prosthetic knees between MIS-TKA with and without PSI were identified. Patients with PSI demonstrated significant positive effects on the reconstructed rigid-body kinematics of the knee, showing clearer coupled flexion/internal rotations - an important kinematic characteristic in healthy knees - than those without PSI during activities with or without weight-bearing. However, none of them showed normal contact patterns. The current findings will be helpful for surgical instrument design, as well as for surgical decision-making in MIS total knee arthroplasty. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 53 条
[11]   Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[12]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[13]   Survivorship analysis of the kinematic stabilizer total knee replacement - A 10- to 14-year follow-up [J].
Emmerson, KP ;
Moran, CG ;
Pinder, IM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :441-445
[14]   Intra- and post-operative accuracy assessments of two different patient-specific instrumentation systems for total knee replacement [J].
Ensini, Andrea ;
Timoncini, Antonio ;
Cenni, Francesco ;
Belvedere, Claudio ;
Fusai, Francesca ;
Leardini, Alberto ;
Giannini, Sandro .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) :621-629
[15]  
FALATYN S, 1995, CLIN ORTHOP RELAT R, P178
[16]   Dynamic in-vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty [J].
Fantozzi, S ;
Leardini, A ;
Banks, SA ;
Marcacci, M ;
Giannini, S ;
Catani, F .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (02) :144-151
[17]   Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: In vivo fluoroscopic analysis during activities of daily living [J].
Fantozzi, Silvia ;
Catani, Fabio ;
Ensini, Andrea ;
Leardini, Alberto ;
Giannini, Sandro .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (12) :2222-2229
[18]   G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191
[19]   Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy [J].
Fregly, BJ ;
Rahman, HA ;
Banks, SA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04) :692-699
[20]   Complications After Minimally Invasive Total Knee Arthroplasty as Compared With Traditional Incision Techniques A Meta-Analysis [J].
Gandhi, Rajiv ;
Smith, Holly ;
Lefaivre, Kelly A. ;
Davey, J. Rod ;
Mahomed, Nizar N. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (01) :29-35