Push out tests on various shear connectors used for cold-formed steel composite beam

被引:5
作者
Rajendran, Senthilkumar [1 ]
Perumalsamy, Jayabalan [1 ]
Mohanraj, Divya [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Civil Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
channel connector; cold-formed composite beam; push-out test; shear connectors; BEHAVIOR; CHANNEL; STRENGTH;
D O I
10.12989/scs.2022.42.3.315
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Shear connectors are key elements that ensure integrity in a composite system. The primary purpose of a shear connector is to bring a high degree of interaction between composite elements. A wide variety of connectors are available for hot-rolled composite construction, connected to the beam through welding. However, with cold-formed members being very thin, welding of shear connectors is not desirable in cold-formed composite constructions. Shear connectors for cold-formed elements are limited in studies as well as in the market. Hence in this study, three different types of shear connectors, namely, single-channel, double channel, and self-tapping screw, were considered, and their performance assessed by the Push-out test as per Eurocode 4. The connection between channel shear connectors and the beam was made using self-tapping screws to avoid welding. The performance of the connectors was analyzed based on their ultimate capacity, characteristic capacity, ductility, and slippage during loading. Strength to weight ratio was also carried out to understand the proposed connectors' suitability for conventional ones. The results showed relatively higher initial stiffness and ductility for double channel connectors than other connectors. Also, self-tapping screws had a higher strength to weight ratio with low ductility.
引用
收藏
页码:315 / 323
页数:9
相关论文
共 30 条
[1]   Behavior of shear connectors in composite column of cold-formed steel with lipped C-channel assembled with ferro-cement jacket [J].
Alenezi, K. ;
Tahir, M. M. ;
Alhajri, T. ;
Badr, M. R. K. ;
Mirza, J. .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 84 :39-45
[2]   Behavior of pre-cast U-Shaped Composite Beam integrating cold-formed steel with ferro-cement slab [J].
Alhajri, T. M. ;
Tahir, M. M. ;
Azimi, M. ;
Mirza, J. ;
Lawan, M. M. ;
Alenezi, K. K. ;
Ragaee, M. B. .
THIN-WALLED STRUCTURES, 2016, 102 :18-29
[3]  
Allen D, 2006, P STRUCTURES C EXPOS, P54, DOI [10.1061/40889(201, DOI 10.1061/40889(201]
[4]  
[Anonymous], 2007, IS 800:2007
[5]  
[Anonymous], 2004, DESIGN COMPOSITE 1 1
[6]  
[Anonymous], 2013, STANDARD TEST METHOD, DOI DOI 10.1520/E0008
[7]  
ANSI/AISC 360, 2016, Specification for structural steel buildings
[8]   Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams [J].
Bamaga, S. O. ;
Tahir, M. M. ;
Tan, C. S. ;
Shek, P. N. ;
Aghlara, R. .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 223 :288-298
[9]   V-shaped shear connector for composite steel-concrete beam [J].
Bezerra, Luciano M. ;
Cavalcante, Otavio O. ;
Chater, Latif ;
Bonilla, Jorge .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 :162-174
[10]   Axial strength of back-to-back cold-formed steel channels with edge-stiffened holes, un-stiffened holes and plain webs [J].
Chen, Boshan ;
Roy, Krishanu ;
Uzzaman, Asraf ;
Raftery, Gary ;
Lim, James B. P. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174