A highly selective and ratiometric fluorescent probe for cyanide by rationally altering the susceptible H-atom

被引:32
作者
Hao, Yuanqiang [1 ]
Khac Hong Nguyen [2 ]
Zhang, Yintang [1 ]
Zhang, Guan [1 ]
Fan, Shengnan [1 ]
Li, Fen [1 ]
Guo, Chao [1 ]
Lu, Yuanyuan [1 ]
Song, Xiaoqing [1 ]
Qu, Peng [1 ]
Liu, You-Nian [2 ]
Xu, Maotian [1 ]
机构
[1] Shangqiu Normal Univ, Coll Chem & Chem Engn, Henan Key Lab Biomol Recognit & Sensing, Shangqiu 476000, Peoples R China
[2] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Alkylation; Cyanide detection; Trifluoroethylamine group; Naphthalimide; Sensing strategy; SENSITIVE FLUOROMETRIC DETECTION; TURN-ON FLUORESCENT; NAKED-EYE; HORSERADISH-PEROXIDASE; FLUOROGENIC DETECTION; ION CHROMATOGRAPHY; COLORIMETRIC PROBE; DRINKING-WATER; AQUEOUS-MEDIA; CHEMODOSIMETER;
D O I
10.1016/j.talanta.2017.08.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly selective and ratiometric fluorescent probe for cyanide was rationally designed and synthesized. The probe comprises a fluorophore unit of naphthalimide and a CN- acceptor of methylated trifluoroacetamide group. For these previous reported trifluoroacetamide derivative-based cyanide chemosensors, the H-atom of amide adjacent to trifluoroacetyl group is susceptible to be attacked by various anions (CN- itself, F-, AcO-, et al.) and even the solvent molecule, which resulted in the bewildered reaction mechanism and poor selectivity of the assay. In this work, the susceptible H-atom of trifluoroacetamide was artfully substituted by alkyl group. Thus a highly specific fluorescent probe was developed for cyanide sensing. Upon the nucleophilic addition of cyanide anion to the carbonyl of trifluoroacetamide moiety of the probe, the ICT process of the probe was significantly enhanced and leading to a remarkable red shift in both absorption and emission spectra of the probe. This fluorescent assay showed a linear range of 1.0-80.0 mu M and a LOD (limit of detection) of 0.23 mu M. All the investigated interference have no influence on the sensing behavior of the probe toward cyanide. Moreover, by coating on TLC plate, the probe can be utilized for practical detection of trace cyanide in water samples.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 71 条
[1]   Single Electron Transfer-Driven Multi-Dimensional Signal Read-out Function of TCNQ as an "Off-the-Shelf" Detector for Cyanide [J].
Ajayakumar, M. R. ;
Mandal, Kalyanashis ;
Rawat, Kamla ;
Asthana, Deepak ;
Pandey, Ravindra ;
Sharma, Akanksha ;
Yadav, Sarita ;
Ghosh, Subhasis ;
Mukhopadhyay, Pritam .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (15) :6996-7000
[2]   Amperometric inhibition biosensors based on horseradish peroxidase and gold sononanoparticles immobilized onto different electrodes for cyanide measurements [J].
Attar, Aisha ;
Cubillana-Aguilera, Laura ;
Naranjo-Rodriguez, Ignacio ;
Hidalgo-Hidalgo de Cisneros, Jose Luis ;
Maria Palacios-Santander, Jose ;
Amine, Aziz .
BIOELECTROCHEMISTRY, 2015, 101 :84-91
[3]   A Highly Selective Chemosensor for Cyanide Derived from a Formyl-Functionalized Phosphorescent Iridium(III) Complex [J].
Bejoymohandas, K. S. ;
Kumar, Ajay ;
Sreenadh, S. ;
Varathan, E. ;
Varughese, S. ;
Subramanian, V. ;
Reddy, M. L. P. .
INORGANIC CHEMISTRY, 2016, 55 (07) :3448-3461
[4]   Visual & reversible sensing of cyanide in real samples by an effective ratiometric colorimetric probe & logic gate application [J].
Bhardwaj, Shubhrajyotsna ;
Singh, Ashok Kumar .
JOURNAL OF HAZARDOUS MATERIALS, 2015, 296 :54-60
[5]   A highly selective and sensitive Zn(II) complex-based chemosensor for sequential recognition of Cu(II) and cyanide [J].
Cao, Wei ;
Zheng, Xiang-Jun ;
Fang, De-Cai ;
Jin, Lin-Pei .
DALTON TRANSACTIONS, 2014, 43 (19) :7298-7303
[6]   A simple 7-azaindole-based ratiometric fluorescent sensor for detection of cyanide in aqueous media [J].
Chen, Kew-Yu ;
Lin, Wei-Chi .
DYES AND PIGMENTS, 2015, 123 :1-7
[7]   A new highly selective fluorescent turn-on chemosensor for cyanide anion [J].
Chen, Yabin ;
Shi, Wei ;
Hui, Yonghai ;
Sun, Xinhua ;
Xu, Linxian ;
Feng, Lei ;
Xie, Zhengfeng .
TALANTA, 2015, 137 :38-42
[8]   Nature of the inhibition of horseradish peroxidase and mitochondrial cytochrome c oxidase by cyanyl radical [J].
Chen, YR ;
Deterding, LJ ;
Tomer, KB ;
Mason, RP .
BIOCHEMISTRY, 2000, 39 (15) :4415-4422
[9]   Reaction-Based Colorimetric Cyanide Chemosensors: Rapid Naked-Eye Detection and High Selectivity [J].
Cheng, Xiaohong ;
Zhou, Yue ;
Qin, Jingui ;
Li, Zhen .
ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (04) :2133-2138
[10]   Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection [J].
Christison, Terri T. ;
Rohrer, Jeffrey S. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (01) :31-39