Acoustic characteristics of broaching procedure for post-operative stem subsidence in cementless total hip arthroplasty

被引:10
作者
Zhuang, Xu [1 ]
Homma, Yasuhiro [1 ]
Ishii, Seiya [1 ]
Shirogane, Yuichi [1 ]
Tanabe, Hiroki [1 ]
Baba, Tomonori [1 ]
Kaneko, Kazuo [1 ]
Sato, Taichi [2 ]
Ishijima, Muneaki [1 ]
机构
[1] Juntendo Univ, Dept Orthopaed Surg, Sch Med, Tokyo, Japan
[2] Tokyo Denki Univ, Dept Adv Machinery Engn, Sch Engn, Adachi Ku, 5 Senju Asahi Cho, Tokyo 1208551, Japan
关键词
Total hip arthroplasty; Stem subsidence; Cementless stem; Acoustic analysis; RISK; FILL;
D O I
10.1007/s00264-021-05278-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Avoiding stem subsidence is crucial for achieving better outcome for cementless total hip arthroplasty (THA). The aim of this study was to develop a prediction model for the incidence of post-operative stem subsidence using full quantitative acoustic parameters in hammering sound during the broaching procedure and to assess the accuracy of this prediction model. Methods The acoustic parameters of the hammering sounds during a broaching procedure for 55 hips in 49 patients who underwent THAs with cementless taper-wedged stem were analysed. The stem subsidence was assessed at one month post-operatively, and the relationship between the acoustic parameters and the value of stem subsidence was investigated. Results The average stem subsidence was 2.15 +/- 2.91 mm. The subsidence 3 mm or more was observed in eleven hips (20%), and 5 mm or more was observed in seven hips (12.7%). Basic patient's characteristics, preoperative femoral morphology and immediate post-operative canal fill ratio and stem alignment were not significantly related to the volume of stem subsidence. Nine acoustic parameters were significantly correlated with the value of subsidence. The prediction model for post-operative subsidence using only acoustic parameters during broaching procedure was established, and this model showed a positive prediction value of 100% and a negative prediction value of 90.6% for post-operative stem subsidence at 5 mm or more. Conclusion Post-operative stem subsidence can be predicted by using acoustic parameters of the hammering sound during the broaching procedure. Our results suggest that we are at the start of a new era in which novel and innovative smart technologies can be used to assist in orthopaedic surgery.
引用
收藏
页码:741 / 748
页数:8
相关论文
共 20 条
[1]   Difference in Stem Alignment Between the Direct Anterior Approach and the Posterolateral Approach in Total Hip Arthroplasty [J].
Abe, Hirohito ;
Sakai, Takashi ;
Takao, Masaki ;
Nishii, Takashi ;
Nakamura, Nobuo ;
Sugano, Nobuhiko .
JOURNAL OF ARTHROPLASTY, 2015, 30 (10) :1761-1766
[2]   Differences in subsidence rate between alternative designs of a commonly used uncemented femoral stem [J].
Al-Najjim, Munnan ;
Khattak, Usman ;
Sim, Juluis ;
Chambers, Iain .
JOURNAL OF ORTHOPAEDICS, 2016, 13 (04) :322-326
[3]   Use of traction table did not increase complications in total hip arthroplasty through direct anterior approach performed by novice surgeon [J].
Banno, Sammy ;
Baba, Tomonori ;
Tanabe, Hiroki ;
Homma, Yasuhiro ;
Ochi, Hironori ;
Watari, Taiji ;
Kobayashi, Hideo ;
Kaneko, Kazuo .
JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (02)
[4]  
Brown Thomas E, 2002, J Am Acad Orthop Surg, V10, P385
[5]   Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty [J].
Chambers, Bryan ;
St Clair, Selvon F. ;
Froimson, Mark I. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (04) :71-74
[6]   Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study [J].
Goossens, Quentin ;
Pastrav, Leonard ;
Roosen, Jorg ;
Mulier, Michiel ;
Desmet, Wim ;
Vander Sloten, Jos ;
Denis, Kathleen .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (06) :1164-1173
[7]   Does the Canal Fill Ratio and Femoral Morphology of Asian Females Influence Early Radiographic Outcomes of Total Hip Arthroplasty With an Uncemented Proximally Coated, Tapered-Wedge Stem? [J].
Ishii, Seiya ;
Homma, Yasuhiro ;
Baba, Tomonori ;
Ozaki, Yu ;
Matsumoto, Mikio ;
Kaneko, Kazuo .
JOURNAL OF ARTHROPLASTY, 2016, 31 (07) :1524-1528
[8]  
KUYPER P, 1972, AUDIOLOGY, V11, P277
[9]   Differences in femoral component subsidence rate after THA using an uncemented collarless femoral stem: full weight-bearing with an enhanced recovery rehabilitation versus partial weight-bearing [J].
Leiss, Franziska ;
Goetz, Julia Sabrina ;
Meyer, Matthias ;
Maderbacher, Gunther ;
Reinhard, Jan ;
Parik, Lukas ;
Grifka, Joachim ;
Greimel, Felix .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (04) :673-680
[10]   Increased risk of intraoperative and early postoperative periprosthetic femoral fracture with uncemented stems 7,169 total hip arthroplasties from 8 Danish centers [J].
Lindberg-Larsen, Martin ;
Jorgensen, Christoffer C. ;
Solgaard, Soren ;
Kjersgaard, Anne G. ;
Kehlet, Henrik .
ACTA ORTHOPAEDICA, 2017, 88 (04) :390-394