The effects of ventilation and floor heating systems on the dispersion and deposition of fine particles in an enclosed environment

被引:114
作者
Zhou, Yu [1 ]
Deng, Yelin [1 ]
Wu, Peng [2 ]
Cao, Shi-Jie [1 ]
机构
[1] Soochow Univ, Dept Civil & Environm Engn, Suzhou, Peoples R China
[2] Soochow Univ, Dept Mech Engn, Suzhou, Peoples R China
关键词
CFD; Air flow; Particle dispersion; Ventilation; Floor heating; DRIFT-FLUX MODEL; TURBULENT MIXED CONVECTION; INDOOR AIR-QUALITY; AIRBORNE PARTICLES; HEALTH IMPACTS; NORTHERN CHINA; POLLUTION; PM2.5; ROOMS; SIMULATIONS;
D O I
10.1016/j.buildenv.2017.08.049
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recent years, most cities in China suffer from ambient particulate matter pollution, especially in winter. The absence of fresh air system in most northern heating buildings in winter results in the poor indoor air quality. This work aims to deal with the particle dispersion in a ventilated and floor-heated indoor environment by using experimental measurements and computational fluid dynamics (CFD) methods. Two ventilation systems were considered, i.e., top & down supply. Firstly, experiments were conducted to validate the velocity and particle concentrations by CFD simulation. Secondly, unsteady particles (with the diameter of 1 Jim) dispersion was simulated with different inlet velocities (i.e., 0.3, 0.4 and 0.5 m/s) and floor temperatures (i.e., 293, 298, 303 and 308 K) in a ventilated and floor-heated chamber. Lagrangian method was employed for particles tracking. It is found that the higher the inlet velocity, the faster particle concentration decayed. For the same inlet velocity, particles in the chamber were removed faster with the increase of floor temperature. When the inlet velocity was 0.5 m/s and the floor temperatures were 293 and 308 K, it took 391s and 200s respectively for normalized concentration decreasing to 0.1. The number of particles deposited on the floor decreased with the increase of the inlet velocity and the floor temperature. This study also identifies that when the floor temperature was 308 K, the removing time is reduced by 15% for normalized particle concentration with the down-supply ventilation mode. These findings would be facilitating for the future design of ventilation and heating systems. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:192 / 205
页数:14
相关论文
共 55 条
[1]   Poor air quality in classrooms related to asthma and rhinitis in primary schoolchildren of the French 6 Cities Study [J].
Annesi-Maesano, Isabella ;
Hulin, Marion ;
Lavaud, Francois ;
Raherison, Chantal ;
Kopferschmitt, Christine ;
de Blay, Frederic ;
Charpin, Denis Andre ;
Denis, Caillaud .
THORAX, 2012, 67 (08) :682-688
[2]  
[Anonymous], 2017, AIR QUALITY INDEX BE
[3]  
[Anonymous], 2003, Tech. Rep.
[4]   Computational modeling of particle transport and distribution emitted from a Laserjet printer in a ventilated room with different ventilation configurations [J].
Ansaripour, Mehrzad ;
Abdolzadeh, Morteza ;
Sargazizadeh, Saleh .
APPLIED THERMAL ENGINEERING, 2016, 103 :920-933
[5]   Studying passive ultrafine particle dispersion in a room with a heat source [J].
Ardkapan, Siamak R. ;
Nielsen, Peter V. ;
Afshari, Alireza .
BUILDING AND ENVIRONMENT, 2014, 71 :1-6
[6]  
Biowski J. Go, 2002, DYNAMICS 3 DIMENSION, V45, P2611
[7]   On the construction and use of linear low-dimensional ventilation models [J].
Cao, S. -J. ;
Meyers, J. .
INDOOR AIR, 2012, 22 (05) :427-441
[8]  
Cao S.J., 2016, RSC ADV, V2016
[9]   An investigation of the PM2.5 and NO2 concentrations and their human health impacts in the metro subway system of Suzhou, China [J].
Cao, Shi-Jie ;
Kong, Xiang-Ri ;
Li, Linyan ;
Zhang, Weirong ;
Ye, Zi-Ping ;
Deng, Yelin .
ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2017, 19 (05) :666-675
[10]   Influence of turbulent boundary conditions on RANS simulations of pollutant dispersion in mechanically ventilated enclosures with transitional slot Reynolds number [J].
Cao, Shi-Jie ;
Meyers, Johan .
BUILDING AND ENVIRONMENT, 2013, 59 :397-407