A Complete Control Startegy of DFIG Connected to The Grid for Wind Energy Conversion Systems

被引:0
作者
Bakouri, Anass [1 ]
Mahmoudi, Hassane [1 ]
Barara, Mohamed [1 ]
Abbou, Ahmed [1 ]
Bennassar, Abderrahim [1 ]
Moutchou, Mohamed [1 ]
机构
[1] Mohammed V Univ, Dept Elect Engn, Mohammadia Sch Engineers, Rabat, Morocco
来源
PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15) | 2015年
关键词
Direct Torque Control (DTC); Doubly Fed Induction Generator (DFIG); Maximum Power Point Tracking (MPPT); Wind Energy Conversion System (WECS); POWER-CONTROL; TURBINE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The doubly fed induction generator (DFIG) is most exploited for wind power generation, It provides the benefits of variable speed operation by improved power quality, increased energy capture, and reduced mechanical stress on the wind turbine, The proposed algorithm presented in this paper is applied to a Doubly Fed Induction Generator (DFIG) with a stator directly connected to the grid and a rotor connected to the grid through a back-to-back AC-DC-AC, PWM converter by using both control strategy, Direct Torque Control (DTC) to control the electromagnetic torque in order to extract the maximum power, and vector control for grid side converter to control the reactive power injected to the network and to regulate the DC bus voltage, the pitch control is also presented to limit the generator power at its rated value of power. Simulation results for a 1,5 MW WECS with DFIG confirm the effectiveness and the performance of the global proposed approaches.
引用
收藏
页码:464 / 469
页数:6
相关论文
共 13 条
  • [1] Nonlinear control with wind estimation of a DFIG variable speed wind turbine for power capture optimization
    Boukhezzar, B.
    Siguerdidjane, H.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (04) : 885 - 892
  • [2] Dynamic modelling and control of fully rated converter wind turbines
    Caliao, Nolan D.
    [J]. RENEWABLE ENERGY, 2011, 36 (08) : 2287 - 2297
  • [3] Variable-speed wind power generation using doubly fed wound rotor induction machine - A comparison with alternative schemes
    Datta, R
    Ranganathan, VT
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (03) : 414 - 421
  • [4] Rotor power control in doubly fed induction generator wind turbine under grid faults
    Hachicha, Fatma
    Krichen, Lotfi
    [J]. ENERGY, 2012, 44 (01) : 853 - 861
  • [5] VSC-based direct torque and reactive power control of doubly fed induction generator
    Hu, Jiabing
    Yuan, Xiaoming
    [J]. RENEWABLE ENERGY, 2012, 40 (01) : 13 - 23
  • [6] Kumar Rajesh, 2007, IET-UK International Conference on Information and Communication Technology in Electrical Sciences (ICTES 2007), P361, DOI 10.1049/ic:20070638
  • [7] Aggregated models and transient performances of a mixed wind farm with different wind turbine generator systems
    Li, H.
    Yang, C.
    Zhao, B.
    Wang, H. S.
    Chen, Z.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2012, 92 : 1 - 10
  • [8] Simplified Modeling of a DFIG for Transient Studies in Wind Power Applications
    Luna, Alvaro
    de Araujo Lima, Francisco Kleber
    Santos, David
    Rodriguez, Pedro
    Watanabe, Edson H.
    Arnaltes, Santiago
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (01) : 9 - 20
  • [9] Madhav G. Venu, 2012, IJPEDS, V2, P409
  • [10] LQG Design for Megawatt-Class WECS With DFIG Based on Functional Models' Fidelity Prerequisites
    Muhando, Endusa Billy
    Senjyu, Tomonobu
    Uehara, Aki
    Funabashi, Toshihisa
    Kim, Chul-Hwan
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (04) : 893 - 904